Melt temperature field measurement in single screw extrusion using thermocouple meshes.

No === The development and validation of a sensor for extrusion melt temperature field measurement is described. A grid of opposing thermocouple wires was constructed and held in position by a supporting frame. Wires were joined together at crossing points to form thermocouple junctions, which were...

Full description

Bibliographic Details
Main Authors: Brown, Elaine C., Kelly, Adrian L., Coates, Philip D.
Language:en
Published: 2009
Subjects:
Online Access:http://hdl.handle.net/10454/3255
id ndltd-BRADFORD-oai-bradscholars.brad.ac.uk-10454-3255
record_format oai_dc
spelling ndltd-BRADFORD-oai-bradscholars.brad.ac.uk-10454-32552019-08-31T03:02:09Z Melt temperature field measurement in single screw extrusion using thermocouple meshes. Brown, Elaine C. Kelly, Adrian L. Coates, Philip D. Extrusion melt temperature field measurement Shear heating effects Single screw extrusion Thermocouple meshes No The development and validation of a sensor for extrusion melt temperature field measurement is described. A grid of opposing thermocouple wires was constructed and held in position by a supporting frame. Wires were joined together at crossing points to form thermocouple junctions, which were computer monitored. The mesh was used to monitor melt temperature fields during single screw extrusion at the die entrance. Design and construction of the mesh is described in addition to experimental optimization of wire diameter and junction forming. Calibration of the sensor and potential measurement errors including shear heating effects are discussed. Initial results from single screw extrusion are presented for a commercial grade of low density polyethylene using five- and seven-junction thermocouple meshes. The dependence of melt temperature profile on screw speed is illustrated. At low screw speeds melt temperature profiles were flat in shape and higher than set wall temperatures. At higher screw speeds the profiles became more pointed in shape. Use of higher resolution sensors exposed more complex temperature profiles with shoulder regions. 2009-08-10T09:03:54Z 2009-08-10T09:03:54Z 2004 Article No full-text available in the repository Brown, E.C., Kelly, A.L. and Coates, P.D. (2004). Melt temperature field measurement in single screw extrusion using thermocouple meshes. Review of Scientific Instruments. Vol. 75, No. 1, pp. 4742-4748. http://hdl.handle.net/10454/3255 en http://dx.doi.org/10.1063/1.1808895
collection NDLTD
language en
sources NDLTD
topic Extrusion melt temperature field measurement
Shear heating effects
Single screw extrusion
Thermocouple meshes
spellingShingle Extrusion melt temperature field measurement
Shear heating effects
Single screw extrusion
Thermocouple meshes
Brown, Elaine C.
Kelly, Adrian L.
Coates, Philip D.
Melt temperature field measurement in single screw extrusion using thermocouple meshes.
description No === The development and validation of a sensor for extrusion melt temperature field measurement is described. A grid of opposing thermocouple wires was constructed and held in position by a supporting frame. Wires were joined together at crossing points to form thermocouple junctions, which were computer monitored. The mesh was used to monitor melt temperature fields during single screw extrusion at the die entrance. Design and construction of the mesh is described in addition to experimental optimization of wire diameter and junction forming. Calibration of the sensor and potential measurement errors including shear heating effects are discussed. Initial results from single screw extrusion are presented for a commercial grade of low density polyethylene using five- and seven-junction thermocouple meshes. The dependence of melt temperature profile on screw speed is illustrated. At low screw speeds melt temperature profiles were flat in shape and higher than set wall temperatures. At higher screw speeds the profiles became more pointed in shape. Use of higher resolution sensors exposed more complex temperature profiles with shoulder regions.
author Brown, Elaine C.
Kelly, Adrian L.
Coates, Philip D.
author_facet Brown, Elaine C.
Kelly, Adrian L.
Coates, Philip D.
author_sort Brown, Elaine C.
title Melt temperature field measurement in single screw extrusion using thermocouple meshes.
title_short Melt temperature field measurement in single screw extrusion using thermocouple meshes.
title_full Melt temperature field measurement in single screw extrusion using thermocouple meshes.
title_fullStr Melt temperature field measurement in single screw extrusion using thermocouple meshes.
title_full_unstemmed Melt temperature field measurement in single screw extrusion using thermocouple meshes.
title_sort melt temperature field measurement in single screw extrusion using thermocouple meshes.
publishDate 2009
url http://hdl.handle.net/10454/3255
work_keys_str_mv AT brownelainec melttemperaturefieldmeasurementinsinglescrewextrusionusingthermocouplemeshes
AT kellyadrianl melttemperaturefieldmeasurementinsinglescrewextrusionusingthermocouplemeshes
AT coatesphilipd melttemperaturefieldmeasurementinsinglescrewextrusionusingthermocouplemeshes
_version_ 1719239487903498240