The intermodal reliability of regulating exercise intensity using ratings of perceived exertion

The purpose of this study was to evaluate the intermodal reliability of perceptually-based exercise intensity among four machines: Treadmill (TM), Stationary cycle (CB), Body Trec elliptical arm/leg (BT), and AirDyne (AD). Nineteen subjects (8 male and 11 female; age 44 + 12 yrs) completed one GXT o...

Full description

Bibliographic Details
Main Author: Burkhart, Tami L.
Other Authors: Whaley, Mitchell H.
Format: Others
Published: 2011
Subjects:
Online Access:http://cardinalscholar.bsu.edu/handle/handle/186629
http://liblink.bsu.edu/uhtbin/catkey/1136711
id ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-186629
record_format oai_dc
spelling ndltd-BSU-oai-cardinalscholar.bsu.edu-handle-1866292014-08-09T03:33:39ZThe intermodal reliability of regulating exercise intensity using ratings of perceived exertionBurkhart, Tami L.Exercise -- Evaluation.Aerobic exercises -- Testing.Exercise tests.Exercise -- Equipment and supplies -- Reliability.Exercise -- Physiological aspects.The purpose of this study was to evaluate the intermodal reliability of perceptually-based exercise intensity among four machines: Treadmill (TM), Stationary cycle (CB), Body Trec elliptical arm/leg (BT), and AirDyne (AD). Nineteen subjects (8 male and 11 female; age 44 + 12 yrs) completed one GXT on each of the machines, following a mode-specific protocol. Subjects also completed two 15 minute production trials (PTs) on each machine at self-selected workrates corresponding to target RPEs of 11-12 (L) and 15-16 (H). In the PTs, workloads were self-adjusted through the first 5 minutes and then remained stable for the rest of the trial. Modes were randomly assigned, and subjects were blinded to the workload throughout each trial. Heart rate (HR) and oxygen uptake (V02) were obtained during the final 5 min. of each trial using a Polar HR monitor and Aerosport TEEM 100. Also, blood lactate (BLC) was sampled immediately following exercise at each intensity. Intermodal reliability was assessed using ANOVA, intraclass correlations (R), coefficients of variation (CV), and mean absolute differences for HR, V02, and BLC during the second PT. ANOVA revealed nointeraction for BLC at either the LOW or HIGH. Post -hoc analysis showed the TM and/or BT to produce significantly higher physiological responses at both intensity levels. At the L and H, intermodal Rs were: HR (.84/.88), VO2 (8/.77) and BLC (0.09/0.67). Significant intrasubject differences were observed at the L for HR (11-47bpm, VO2 (.04-1.46 L/min), and BLC (.29-12.94 mM/L). The H trials followed a very similar trend. Using a HR criteria of +2 beats/15 sec. to assess intrasubject reliability, 0% of the subjects were reliable at both the L and H. This data suggests that perceptually-based exercise across multiple modes is associated with significant intraindividual variability, and reliability is dependent upon the statistical design and physiological variable being used. In conclusion, it is recommended that extensive exercise testing be performed to ensure that individual participants can reliably use the RPE scale, prior to using an RPE value to prescribe the intensity of exercise.School of Physical EducationWhaley, Mitchell H.2011-06-03T19:38:47Z2011-06-03T19:38:47Z19991999viii, 85 leaves : ill. ; 28 cm.LD2489.Z78 1999 .B87http://cardinalscholar.bsu.edu/handle/handle/186629http://liblink.bsu.edu/uhtbin/catkey/1136711Virtual Press
collection NDLTD
format Others
sources NDLTD
topic Exercise -- Evaluation.
Aerobic exercises -- Testing.
Exercise tests.
Exercise -- Equipment and supplies -- Reliability.
Exercise -- Physiological aspects.
spellingShingle Exercise -- Evaluation.
Aerobic exercises -- Testing.
Exercise tests.
Exercise -- Equipment and supplies -- Reliability.
Exercise -- Physiological aspects.
Burkhart, Tami L.
The intermodal reliability of regulating exercise intensity using ratings of perceived exertion
description The purpose of this study was to evaluate the intermodal reliability of perceptually-based exercise intensity among four machines: Treadmill (TM), Stationary cycle (CB), Body Trec elliptical arm/leg (BT), and AirDyne (AD). Nineteen subjects (8 male and 11 female; age 44 + 12 yrs) completed one GXT on each of the machines, following a mode-specific protocol. Subjects also completed two 15 minute production trials (PTs) on each machine at self-selected workrates corresponding to target RPEs of 11-12 (L) and 15-16 (H). In the PTs, workloads were self-adjusted through the first 5 minutes and then remained stable for the rest of the trial. Modes were randomly assigned, and subjects were blinded to the workload throughout each trial. Heart rate (HR) and oxygen uptake (V02) were obtained during the final 5 min. of each trial using a Polar HR monitor and Aerosport TEEM 100. Also, blood lactate (BLC) was sampled immediately following exercise at each intensity. Intermodal reliability was assessed using ANOVA, intraclass correlations (R), coefficients of variation (CV), and mean absolute differences for HR, V02, and BLC during the second PT. ANOVA revealed nointeraction for BLC at either the LOW or HIGH. Post -hoc analysis showed the TM and/or BT to produce significantly higher physiological responses at both intensity levels. At the L and H, intermodal Rs were: HR (.84/.88), VO2 (8/.77) and BLC (0.09/0.67). Significant intrasubject differences were observed at the L for HR (11-47bpm, VO2 (.04-1.46 L/min), and BLC (.29-12.94 mM/L). The H trials followed a very similar trend. Using a HR criteria of +2 beats/15 sec. to assess intrasubject reliability, 0% of the subjects were reliable at both the L and H. This data suggests that perceptually-based exercise across multiple modes is associated with significant intraindividual variability, and reliability is dependent upon the statistical design and physiological variable being used. In conclusion, it is recommended that extensive exercise testing be performed to ensure that individual participants can reliably use the RPE scale, prior to using an RPE value to prescribe the intensity of exercise. === School of Physical Education
author2 Whaley, Mitchell H.
author_facet Whaley, Mitchell H.
Burkhart, Tami L.
author Burkhart, Tami L.
author_sort Burkhart, Tami L.
title The intermodal reliability of regulating exercise intensity using ratings of perceived exertion
title_short The intermodal reliability of regulating exercise intensity using ratings of perceived exertion
title_full The intermodal reliability of regulating exercise intensity using ratings of perceived exertion
title_fullStr The intermodal reliability of regulating exercise intensity using ratings of perceived exertion
title_full_unstemmed The intermodal reliability of regulating exercise intensity using ratings of perceived exertion
title_sort intermodal reliability of regulating exercise intensity using ratings of perceived exertion
publishDate 2011
url http://cardinalscholar.bsu.edu/handle/handle/186629
http://liblink.bsu.edu/uhtbin/catkey/1136711
work_keys_str_mv AT burkharttamil theintermodalreliabilityofregulatingexerciseintensityusingratingsofperceivedexertion
AT burkharttamil intermodalreliabilityofregulatingexerciseintensityusingratingsofperceivedexertion
_version_ 1716710355611156480