Reliability of 3D laser-based anthropometry and comparison with classical anthropometry

Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to com...

Full description

Bibliographic Details
Main Authors: Kühnapfel, Andreas, Ahnert, Peter, Löffler, Markus, Broda, Anja, Scholz, Markus
Other Authors: Universität Leipzig, Medizinische Fakultät
Format: Article
Language:English
Published: Universitätsbibliothek Leipzig 2016
Subjects:
Online Access:http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114
http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114
http://www.qucosa.de/fileadmin/data/qucosa/documents/20411/OAP-2016-040_Kuehnapfel_srep26672.pdf
id ndltd-DRESDEN-oai-qucosa.de-bsz-15-qucosa-204114
record_format oai_dc
spelling ndltd-DRESDEN-oai-qucosa.de-bsz-15-qucosa-2041142016-06-09T03:28:13Z Reliability of 3D laser-based anthropometry and comparison with classical anthropometry Kühnapfel, Andreas Ahnert, Peter Löffler, Markus Broda, Anja Scholz, Markus Anthropometrie 3D-Scanverfahren manuelle Verfahren anthropometry body scan manual anthropometry ddc:610 Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to compare BS with classical manual anthropometric (CA) assessments with respect to feasibility, reliability, and validity. We performed a study on 108 individuals with multiple measurements of BS and CA to estimate intra- and inter-rater reliabilities for both. We suggested BS equivalents of CA measurements and determined validity of BS considering CA the gold standard. Throughout the study, the overall concordance correlation coefficient (OCCC) was chosen as indicator of agreement. BS was slightly more time consuming but better accepted than CA. For CA, OCCCs for intra- and inter-rater reliability were greater than 0.8 for all nine quantities studied. For BS, 9 of 154 quantities showed reliabilities below 0.7. BS proxies for CA measurements showed good agreement (minimum OCCC > 0.77) after offset correction. Thigh length showed higher reliability in BS while upper arm length showed higher reliability in CA. Except for these issues, reliabilities of CA measurements and their BS equivalents were comparable. Universitätsbibliothek Leipzig Universität Leipzig, Medizinische Fakultät Universität Leipzig, Medizinische Fakultät Nature Publishing Group, 2016-06-08 doc-type:article application/pdf http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114 urn:nbn:de:bsz:15-qucosa-204114 issn:2045-2322 http://www.qucosa.de/fileadmin/data/qucosa/documents/20411/OAP-2016-040_Kuehnapfel_srep26672.pdf Scientific reports, 6:26672 doi:10.1038/srep26672 eng
collection NDLTD
language English
format Article
sources NDLTD
topic Anthropometrie
3D-Scanverfahren
manuelle Verfahren
anthropometry
body scan
manual anthropometry
ddc:610
spellingShingle Anthropometrie
3D-Scanverfahren
manuelle Verfahren
anthropometry
body scan
manual anthropometry
ddc:610
Kühnapfel, Andreas
Ahnert, Peter
Löffler, Markus
Broda, Anja
Scholz, Markus
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
description Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to compare BS with classical manual anthropometric (CA) assessments with respect to feasibility, reliability, and validity. We performed a study on 108 individuals with multiple measurements of BS and CA to estimate intra- and inter-rater reliabilities for both. We suggested BS equivalents of CA measurements and determined validity of BS considering CA the gold standard. Throughout the study, the overall concordance correlation coefficient (OCCC) was chosen as indicator of agreement. BS was slightly more time consuming but better accepted than CA. For CA, OCCCs for intra- and inter-rater reliability were greater than 0.8 for all nine quantities studied. For BS, 9 of 154 quantities showed reliabilities below 0.7. BS proxies for CA measurements showed good agreement (minimum OCCC > 0.77) after offset correction. Thigh length showed higher reliability in BS while upper arm length showed higher reliability in CA. Except for these issues, reliabilities of CA measurements and their BS equivalents were comparable.
author2 Universität Leipzig, Medizinische Fakultät
author_facet Universität Leipzig, Medizinische Fakultät
Kühnapfel, Andreas
Ahnert, Peter
Löffler, Markus
Broda, Anja
Scholz, Markus
author Kühnapfel, Andreas
Ahnert, Peter
Löffler, Markus
Broda, Anja
Scholz, Markus
author_sort Kühnapfel, Andreas
title Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
title_short Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
title_full Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
title_fullStr Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
title_full_unstemmed Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
title_sort reliability of 3d laser-based anthropometry and comparison with classical anthropometry
publisher Universitätsbibliothek Leipzig
publishDate 2016
url http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114
http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114
http://www.qucosa.de/fileadmin/data/qucosa/documents/20411/OAP-2016-040_Kuehnapfel_srep26672.pdf
work_keys_str_mv AT kuhnapfelandreas reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry
AT ahnertpeter reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry
AT lofflermarkus reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry
AT brodaanja reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry
AT scholzmarkus reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry
_version_ 1718298796722487296