Reliability of 3D laser-based anthropometry and comparison with classical anthropometry
Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to com...
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
Universitätsbibliothek Leipzig
2016
|
Subjects: | |
Online Access: | http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114 http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114 http://www.qucosa.de/fileadmin/data/qucosa/documents/20411/OAP-2016-040_Kuehnapfel_srep26672.pdf |
id |
ndltd-DRESDEN-oai-qucosa.de-bsz-15-qucosa-204114 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-DRESDEN-oai-qucosa.de-bsz-15-qucosa-2041142016-06-09T03:28:13Z Reliability of 3D laser-based anthropometry and comparison with classical anthropometry Kühnapfel, Andreas Ahnert, Peter Löffler, Markus Broda, Anja Scholz, Markus Anthropometrie 3D-Scanverfahren manuelle Verfahren anthropometry body scan manual anthropometry ddc:610 Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to compare BS with classical manual anthropometric (CA) assessments with respect to feasibility, reliability, and validity. We performed a study on 108 individuals with multiple measurements of BS and CA to estimate intra- and inter-rater reliabilities for both. We suggested BS equivalents of CA measurements and determined validity of BS considering CA the gold standard. Throughout the study, the overall concordance correlation coefficient (OCCC) was chosen as indicator of agreement. BS was slightly more time consuming but better accepted than CA. For CA, OCCCs for intra- and inter-rater reliability were greater than 0.8 for all nine quantities studied. For BS, 9 of 154 quantities showed reliabilities below 0.7. BS proxies for CA measurements showed good agreement (minimum OCCC > 0.77) after offset correction. Thigh length showed higher reliability in BS while upper arm length showed higher reliability in CA. Except for these issues, reliabilities of CA measurements and their BS equivalents were comparable. Universitätsbibliothek Leipzig Universität Leipzig, Medizinische Fakultät Universität Leipzig, Medizinische Fakultät Nature Publishing Group, 2016-06-08 doc-type:article application/pdf http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114 urn:nbn:de:bsz:15-qucosa-204114 issn:2045-2322 http://www.qucosa.de/fileadmin/data/qucosa/documents/20411/OAP-2016-040_Kuehnapfel_srep26672.pdf Scientific reports, 6:26672 doi:10.1038/srep26672 eng |
collection |
NDLTD |
language |
English |
format |
Article |
sources |
NDLTD |
topic |
Anthropometrie 3D-Scanverfahren manuelle Verfahren anthropometry body scan manual anthropometry ddc:610 |
spellingShingle |
Anthropometrie 3D-Scanverfahren manuelle Verfahren anthropometry body scan manual anthropometry ddc:610 Kühnapfel, Andreas Ahnert, Peter Löffler, Markus Broda, Anja Scholz, Markus Reliability of 3D laser-based anthropometry and comparison with classical anthropometry |
description |
Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to compare BS with classical manual anthropometric (CA) assessments with respect to feasibility, reliability, and validity. We performed a study on 108 individuals with multiple measurements of
BS and CA to estimate intra- and inter-rater reliabilities for both. We suggested BS equivalents of CA measurements and determined validity of BS considering CA the gold standard. Throughout the study, the overall concordance correlation coefficient (OCCC) was chosen as indicator of agreement. BS was slightly more time consuming but better accepted than CA. For CA, OCCCs for intra- and inter-rater reliability were greater than 0.8 for all nine quantities studied. For BS, 9 of 154 quantities showed reliabilities below 0.7. BS proxies for CA measurements showed good agreement (minimum OCCC > 0.77) after offset correction. Thigh length showed higher reliability in BS while upper arm length showed higher reliability in CA. Except for these issues, reliabilities of CA measurements and their BS equivalents were comparable. |
author2 |
Universität Leipzig, Medizinische Fakultät |
author_facet |
Universität Leipzig, Medizinische Fakultät Kühnapfel, Andreas Ahnert, Peter Löffler, Markus Broda, Anja Scholz, Markus |
author |
Kühnapfel, Andreas Ahnert, Peter Löffler, Markus Broda, Anja Scholz, Markus |
author_sort |
Kühnapfel, Andreas |
title |
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry |
title_short |
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry |
title_full |
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry |
title_fullStr |
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry |
title_full_unstemmed |
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry |
title_sort |
reliability of 3d laser-based anthropometry and comparison with classical anthropometry |
publisher |
Universitätsbibliothek Leipzig |
publishDate |
2016 |
url |
http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114 http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-204114 http://www.qucosa.de/fileadmin/data/qucosa/documents/20411/OAP-2016-040_Kuehnapfel_srep26672.pdf |
work_keys_str_mv |
AT kuhnapfelandreas reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry AT ahnertpeter reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry AT lofflermarkus reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry AT brodaanja reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry AT scholzmarkus reliabilityof3dlaserbasedanthropometryandcomparisonwithclassicalanthropometry |
_version_ |
1718298796722487296 |