Instrumentação e metodologias de mediçãode biopotenciais

=== Biopotential measurement and recording can be seen as a valuable resource in the quest for the understanding of biological systems working principles. It is also a very important tool for medical diagnosis, widely known and accepted in medical literature. Devices used for biopotentialrecording...

Full description

Bibliographic Details
Main Author: Adriano Silva Vale Cardoso
Other Authors: Homero Nogueira Guimarães
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2010
Online Access:http://hdl.handle.net/1843/BUOS-8EAJK4
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8EAJK4
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8EAJK42019-01-21T18:03:05Z Instrumentação e metodologias de mediçãode biopotenciais Adriano Silva Vale Cardoso Homero Nogueira Guimarães Paulo José Abatti Marcio Nogueira de Souza Davies William de Lima Monteiro Porfirio Cabaleiro Cortizo Biopotential measurement and recording can be seen as a valuable resource in the quest for the understanding of biological systems working principles. It is also a very important tool for medical diagnosis, widely known and accepted in medical literature. Devices used for biopotentialrecording are subject of research for a long time, and has improved its characteristics towards more reliable measurement systems. This fact made possible the assessment of new circuits and methods, which, in some cases, represented important achievements for electronic instrumentation. The purpose of this work is the study of biopotential recording systems, focused on the design and evaluation methods for electronic instrumentation. Consequently, improvements are proposed inthese methods and also, new circuits are presented to solve specific problems of the measurement process. The monitoring of cardiovascular physiological parameters are specially concerned, and are achieved through electrocardiogram (ECG) and blood pressure recording in experimental animals. Contributions regarding ECG recording methods are presented. Several hardware modules were constructed in order to reproduce results from technical literature, to validate the proposed design procedures and to demonstrate the effectiveness of the proposed new circuits. Experimental results obtained from aforementioned hardware modules are presented. O registro de biopotenciais pode ser visto como uma prática de grande importância na busca do entendimento sobre o funcionamento de sistemas biológicos. Pode também ser entendido como uma valiosa ferramenta de diagnóstico, amplamente divulgada e adotada na literatura médica. Embora consolidado como instrumento de avaliação fisiológica, os dispositivos utilizados para sua prática vêm evoluindo, o que possibilita que limites sejam transpostos, e, principalmente, quenovas propostas de medição sejam experimentadas. Este trabalho tem como objetivo o estudo dos sistemas de registro de biopotenciais, visando a compilação de métodos de projeto e avaliação de circuitos eletrônicos voltados para essa finalidade. Em consequência, melhorias são propostas nos sistemas de registro. Contribuições são oferecidas na análise e projeto destes sistemas e através da proposição de circuitos para melhoria de aspectos específicos da medição. A monitoração de parâmetros da fisiologia cardiovascular é de especial interesse, concentrando-se em torno da medição de sinais de eletrocardiografia (ECG) e pressão arterial de animais experimentais. Contribuições relacionadas aos m´etodos de registro de ECG estão presentes no texto. Diversos módulos de hardware foram construídos com a finalidade de reproduzir os resultados registrados na literatura, validar os métodos de projeto discutidos, e adicionalmente, demonstrar a eficácia dos circuitos de medição aqui propostos. Um conjunto de resultados experimentais, viabilizados pela construção dos módulos implementados, é apresentado ao final do estudo. 2010-12-16 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis http://hdl.handle.net/1843/BUOS-8EAJK4 por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010015P8 - ENGENHARIA ELÉTRICA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === Biopotential measurement and recording can be seen as a valuable resource in the quest for the understanding of biological systems working principles. It is also a very important tool for medical diagnosis, widely known and accepted in medical literature. Devices used for biopotentialrecording are subject of research for a long time, and has improved its characteristics towards more reliable measurement systems. This fact made possible the assessment of new circuits and methods, which, in some cases, represented important achievements for electronic instrumentation. The purpose of this work is the study of biopotential recording systems, focused on the design and evaluation methods for electronic instrumentation. Consequently, improvements are proposed inthese methods and also, new circuits are presented to solve specific problems of the measurement process. The monitoring of cardiovascular physiological parameters are specially concerned, and are achieved through electrocardiogram (ECG) and blood pressure recording in experimental animals. Contributions regarding ECG recording methods are presented. Several hardware modules were constructed in order to reproduce results from technical literature, to validate the proposed design procedures and to demonstrate the effectiveness of the proposed new circuits. Experimental results obtained from aforementioned hardware modules are presented. === O registro de biopotenciais pode ser visto como uma prática de grande importância na busca do entendimento sobre o funcionamento de sistemas biológicos. Pode também ser entendido como uma valiosa ferramenta de diagnóstico, amplamente divulgada e adotada na literatura médica. Embora consolidado como instrumento de avaliação fisiológica, os dispositivos utilizados para sua prática vêm evoluindo, o que possibilita que limites sejam transpostos, e, principalmente, quenovas propostas de medição sejam experimentadas. Este trabalho tem como objetivo o estudo dos sistemas de registro de biopotenciais, visando a compilação de métodos de projeto e avaliação de circuitos eletrônicos voltados para essa finalidade. Em consequência, melhorias são propostas nos sistemas de registro. Contribuições são oferecidas na análise e projeto destes sistemas e através da proposição de circuitos para melhoria de aspectos específicos da medição. A monitoração de parâmetros da fisiologia cardiovascular é de especial interesse, concentrando-se em torno da medição de sinais de eletrocardiografia (ECG) e pressão arterial de animais experimentais. Contribuições relacionadas aos m´etodos de registro de ECG estão presentes no texto. Diversos módulos de hardware foram construídos com a finalidade de reproduzir os resultados registrados na literatura, validar os métodos de projeto discutidos, e adicionalmente, demonstrar a eficácia dos circuitos de medição aqui propostos. Um conjunto de resultados experimentais, viabilizados pela construção dos módulos implementados, é apresentado ao final do estudo.
author2 Homero Nogueira Guimarães
author_facet Homero Nogueira Guimarães
Adriano Silva Vale Cardoso
author Adriano Silva Vale Cardoso
spellingShingle Adriano Silva Vale Cardoso
Instrumentação e metodologias de mediçãode biopotenciais
author_sort Adriano Silva Vale Cardoso
title Instrumentação e metodologias de mediçãode biopotenciais
title_short Instrumentação e metodologias de mediçãode biopotenciais
title_full Instrumentação e metodologias de mediçãode biopotenciais
title_fullStr Instrumentação e metodologias de mediçãode biopotenciais
title_full_unstemmed Instrumentação e metodologias de mediçãode biopotenciais
title_sort instrumentação e metodologias de mediçãode biopotenciais
publisher Universidade Federal de Minas Gerais
publishDate 2010
url http://hdl.handle.net/1843/BUOS-8EAJK4
work_keys_str_mv AT adrianosilvavalecardoso instrumentacaoemetodologiasdemedicaodebiopotenciais
_version_ 1718845909749465088