SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.

Made available in DSpace on 2017-07-20T12:40:21Z (GMT). No. of bitstreams: 1 Cliciane Guadalupe de Jesus.pdf: 1994532 bytes, checksum: 0f732ce8dacf9081816c07b36ec9e75d (MD5) Previous issue date: 2013-06-21 === In this thesis, it is described the preparation, characterization and application of LbL...

Full description

Bibliographic Details
Main Author: Jesus, Cliciane Guadalupe de
Other Authors: Pessoa, Christiana Andrade
Format: Others
Language:Portuguese
Published: UNIVERSIDADE ESTADUAL DE PONTA GROSSA 2017
Subjects:
Online Access:http://tede2.uepg.br/jspui/handle/prefix/14
id ndltd-IBICT-oai-tede2.uepg.br-prefix-14
record_format oai_dc
collection NDLTD
language Portuguese
format Others
sources NDLTD
topic filmes LbL
polieletrólito Silsesquioxano
biossensor amperométrico
glicose oxidase
LbL films
Silsesquioxane polyelectrolyte
amperometric biosensor
Glucose Oxidase
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA INORGANICA
spellingShingle filmes LbL
polieletrólito Silsesquioxano
biossensor amperométrico
glicose oxidase
LbL films
Silsesquioxane polyelectrolyte
amperometric biosensor
Glucose Oxidase
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA INORGANICA
Jesus, Cliciane Guadalupe de
SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.
description Made available in DSpace on 2017-07-20T12:40:21Z (GMT). No. of bitstreams: 1 Cliciane Guadalupe de Jesus.pdf: 1994532 bytes, checksum: 0f732ce8dacf9081816c07b36ec9e75d (MD5) Previous issue date: 2013-06-21 === In this thesis, it is described the preparation, characterization and application of LbL films based on the 3- n - propylpyridinium silsesquioxane polymer (SiPy+Cl-) and copper (II) tetrasulfophthalocyanine (CuTsPc), denoted as (SiPy+Cl-/CuTsPc)n, for construction of sensors and biosensors. These films (SiPy+Cl-/CuTsPc)n, were applied as a sensor for promethazine hydrochloride (PMZ) and hydrogen peroxide (H2O2). In addition, taking advantage of the property to the film in electrocatalyzing the reduction of H2O2, an enzymatic amperometric biosensor was constructed by the immobilization of the glucose oxidase enzyme (GOx) on the film for detection of glucose, based on the detection of H2O2 produced in the enzymatic reaction. The UV-Vis spectroscopic technique showed that the adsorption of phthalocyanine occurred linearly indicating that the approximately the same amount of the species is immobilized at each bilayer. The interaction between the sulfonic group and the pyridinium ring is responsible for the support of the films due to the shift of the vibration associated with sulfonic groups. The film (SiPy+Cl-/CuTsPc)5 was highly electrocatalytic and sensitive determination of PMZ. The oxidation process of PMZ molecule presented two peaks at 0.48 and 0.79 V. After optimization of the square wave voltammetry parameters (f = 100 s-1, a = 40 mV and ΔEs = 2 mV), the peak at 0.79 V was used for quantification. Accordingly, the modified electrode obtained a linear response of 3.98 x 10-7 to 3.85 x 10-6 mol L-1 with limits of detection (LOD) and quantification (LOQ) equal to 8.71 x 10-9 mol L-1 (2.79 g L-1) and 9.31 x 10-8 mol L-1 (9.31 g L-1), respectively. The recovery in pharmaceutical samples showed high stability, specificity and accuracy of the method in complex samples without any pre-treatment. The film (SiPy+Cl-/CuTsPc)2 showed excellent electrocatalytic activity for the reduction of H2O2 with a wide linear range (4.97 x 10-6 a 4.76 x 10-5 mol L-1) and low detection limit (0.33 x 10-6 mol L-1). This electrode was modified with the glucose oxidase enzyme (GOx) and coated with Nafion® (Nf) film, which was used to prevent leaching of GOx. The Fourier transform infrared, fluorescence and circular dichroism spectroscopics, showed that the GOx enzyme retains its native secondary structure when immobilized on the LbL film. The resulting biosensor (SiPy+Cl-/CuTsPc)2(SiPy+Cl-/GOx/Nf) exhibited a current response which varied linearly with the concentration of glucose in the range of 1-10 mmol L-1, with LOD = 0.17 mmol L-1, sensitivity of 1.397 μA x 10-7/mmol L-1 and a rapid response time, less than 5 seconds. The Michaelis-Menten constant apparent ( appmK ) was 10 mmol L-1. Furthermore, the biosensor also showed good reproducibility, excellent stability and a long life, without loss of enzymatic activity by a one-week period and remained active for more than three weeks. The use of the polymer Nf decreased the effect of interferents on the response of the biosensor. === Esta tese descreve a preparação, a caracterização e a aplicação de filmes automontados entre o polímero cloreto de 3- n -propilpiridínio silsesquioxano (SiPy+Cl-) e a ftalocianina tetrassulfonada de cobre (II) (CuTsPc), designados como (SiPy+Cl-/CuTsPc)n, para a construção de sensores e biossensores. Tais filmes, (SiPy+Cl-/CuTsPc)n, se mostraram promissores como sensor para detecção de cloridrato de prometazina (PMZ) e peróxido de hidrogênio (H2O2). Adicionalmente, tirando-se proveito da propriedade do filme em eletrocatalisar a redução do H2O2, construiu-se um biossensor enzimático amperométrico, a partir da imobilização da enzima glicose oxidase (GOx) sobre o filme, para a detecção de glicose, baseado na detecção do H2O2 produzido na reação enzimática. A técnica de espectroscopia de UV-Vis revelou que a adsorção de ftalocianina ocorre de maneira linear indicando que a cada bicamada depositada aproximadamente a mesma quantidade de material é imobilizado. A interação entre os grupos sulfônicos e o anel piridínio é a responsável pela sustentação dos filmes, devido ao deslocamento da banda associada à vibração dos grupos sulfônicos. O filme (SiPy+Cl-/CuTsPc)5 mostrou propriedades eletrocatalíticas na determinação de PMZ. Este apresentou dois processos de oxidação em 0,48 e 0,79 V. Após a otimização dos parâmetros da voltametria de onda quadrada (f = 100 s-1, a = 40 mV e ΔEs = 2 mV), o pico a 0,79 V foi utilizado para sua quantificação. Nestas condições, o eletrodo modificado obteve uma resposta linear de 3,98 x10-7 a 3,85 x 10-6 mol L-1 com limites de detecção (LD) e quantificação (LQ) iguais a 8,71 x 10-9 mol L-1 (2,79 μg L-1) e 9,31 x 10-8 mol L-1 (9,31 μg L-1), respectivamente. A recuperação em amostras farmacêuticas revelou alta estabilidade, especificidade e precisão do método, sem qualquer pré-tratamento. O filme (SiPy+Cl-/CuTsPc)2 demonstrou excelente atividade eletrocatalítica para redução de H2O2 com uma ampla resposta linear (4,97 x 10-6 a 4,76 x 10-5 mol L-1) e baixo limite de detecção (0,33 x 10-6 mol L-1). Este eletrodo foi modificado com a enzima glicose oxidase (GOx) e recoberto com filme de Nafion® (Nf), que foi usado para prevenir o lixiviamento da GOx. As técnicas espectroscópicas de infravermelho, fluorescência e dicroísmo circular mostraram que a enzima GOx mantém a sua estrutura nativa secundária quando imobilizado sobre o filme LbL. O biossensor resultante (SiPy+Cl-/CuTsPc)2(SiPy+Cl-/GOx/Nf) exibiu uma resposta de corrente que variou linearmente com a concentração de glicose na faixa de 1 a 10 mmol L-1, com LD = 0,17 mmol L-1, sensibilidade de 1,397 x 10-7 μA/mmol L-1 e um rápido tempo de resposta, inferior a 5 s. A constante de Michaelis-Menten aparente ( appmK ) foi de 10 mmol L-1. Além disso, o biossensor também apresentou boa reprodutibilidade, excelente estabilidade e longo tempo de vida, sem diminuição da atividade enzimática por um período de uma semana e permaneceu ativo por mais de três semanas. A utilização do polímero Nf possibilitou a diminuição do efeito de interferentes na resposta do biossensor. Palavras chave: Filmes LbL, polieletrólito Silsesquioxano, Biossensor Amperométrico, Glicose Oxidase.
author2 Pessoa, Christiana Andrade
author_facet Pessoa, Christiana Andrade
Jesus, Cliciane Guadalupe de
author Jesus, Cliciane Guadalupe de
author_sort Jesus, Cliciane Guadalupe de
title SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.
title_short SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.
title_full SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.
title_fullStr SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.
title_full_unstemmed SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.
title_sort sensores eletroquímicos baseados em filmes lbl de ftalocianina metalada e polímero silsesquioxano.
publisher UNIVERSIDADE ESTADUAL DE PONTA GROSSA
publishDate 2017
url http://tede2.uepg.br/jspui/handle/prefix/14
work_keys_str_mv AT jesusclicianeguadalupede sensoreseletroquimicosbaseadosemfilmeslbldeftalocianinametaladaepolimerosilsesquioxano
_version_ 1719006978128216064
spelling ndltd-IBICT-oai-tede2.uepg.br-prefix-142019-03-27T19:17:39Z SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO. Jesus, Cliciane Guadalupe de Pessoa, Christiana Andrade Wohnrath, Karen Sotomayor, Maria Del Pilar Taboada Ribeiro, Emerson Schwingel Tarley, Cesar Ricardo Teixeira Anaissi, Fauze Jaco filmes LbL polieletrólito Silsesquioxano biossensor amperométrico glicose oxidase LbL films Silsesquioxane polyelectrolyte amperometric biosensor Glucose Oxidase CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA INORGANICA Made available in DSpace on 2017-07-20T12:40:21Z (GMT). No. of bitstreams: 1 Cliciane Guadalupe de Jesus.pdf: 1994532 bytes, checksum: 0f732ce8dacf9081816c07b36ec9e75d (MD5) Previous issue date: 2013-06-21 In this thesis, it is described the preparation, characterization and application of LbL films based on the 3- n - propylpyridinium silsesquioxane polymer (SiPy+Cl-) and copper (II) tetrasulfophthalocyanine (CuTsPc), denoted as (SiPy+Cl-/CuTsPc)n, for construction of sensors and biosensors. These films (SiPy+Cl-/CuTsPc)n, were applied as a sensor for promethazine hydrochloride (PMZ) and hydrogen peroxide (H2O2). In addition, taking advantage of the property to the film in electrocatalyzing the reduction of H2O2, an enzymatic amperometric biosensor was constructed by the immobilization of the glucose oxidase enzyme (GOx) on the film for detection of glucose, based on the detection of H2O2 produced in the enzymatic reaction. The UV-Vis spectroscopic technique showed that the adsorption of phthalocyanine occurred linearly indicating that the approximately the same amount of the species is immobilized at each bilayer. The interaction between the sulfonic group and the pyridinium ring is responsible for the support of the films due to the shift of the vibration associated with sulfonic groups. The film (SiPy+Cl-/CuTsPc)5 was highly electrocatalytic and sensitive determination of PMZ. The oxidation process of PMZ molecule presented two peaks at 0.48 and 0.79 V. After optimization of the square wave voltammetry parameters (f = 100 s-1, a = 40 mV and ΔEs = 2 mV), the peak at 0.79 V was used for quantification. Accordingly, the modified electrode obtained a linear response of 3.98 x 10-7 to 3.85 x 10-6 mol L-1 with limits of detection (LOD) and quantification (LOQ) equal to 8.71 x 10-9 mol L-1 (2.79 g L-1) and 9.31 x 10-8 mol L-1 (9.31 g L-1), respectively. The recovery in pharmaceutical samples showed high stability, specificity and accuracy of the method in complex samples without any pre-treatment. The film (SiPy+Cl-/CuTsPc)2 showed excellent electrocatalytic activity for the reduction of H2O2 with a wide linear range (4.97 x 10-6 a 4.76 x 10-5 mol L-1) and low detection limit (0.33 x 10-6 mol L-1). This electrode was modified with the glucose oxidase enzyme (GOx) and coated with Nafion® (Nf) film, which was used to prevent leaching of GOx. The Fourier transform infrared, fluorescence and circular dichroism spectroscopics, showed that the GOx enzyme retains its native secondary structure when immobilized on the LbL film. The resulting biosensor (SiPy+Cl-/CuTsPc)2(SiPy+Cl-/GOx/Nf) exhibited a current response which varied linearly with the concentration of glucose in the range of 1-10 mmol L-1, with LOD = 0.17 mmol L-1, sensitivity of 1.397 μA x 10-7/mmol L-1 and a rapid response time, less than 5 seconds. The Michaelis-Menten constant apparent ( appmK ) was 10 mmol L-1. Furthermore, the biosensor also showed good reproducibility, excellent stability and a long life, without loss of enzymatic activity by a one-week period and remained active for more than three weeks. The use of the polymer Nf decreased the effect of interferents on the response of the biosensor. Esta tese descreve a preparação, a caracterização e a aplicação de filmes automontados entre o polímero cloreto de 3- n -propilpiridínio silsesquioxano (SiPy+Cl-) e a ftalocianina tetrassulfonada de cobre (II) (CuTsPc), designados como (SiPy+Cl-/CuTsPc)n, para a construção de sensores e biossensores. Tais filmes, (SiPy+Cl-/CuTsPc)n, se mostraram promissores como sensor para detecção de cloridrato de prometazina (PMZ) e peróxido de hidrogênio (H2O2). Adicionalmente, tirando-se proveito da propriedade do filme em eletrocatalisar a redução do H2O2, construiu-se um biossensor enzimático amperométrico, a partir da imobilização da enzima glicose oxidase (GOx) sobre o filme, para a detecção de glicose, baseado na detecção do H2O2 produzido na reação enzimática. A técnica de espectroscopia de UV-Vis revelou que a adsorção de ftalocianina ocorre de maneira linear indicando que a cada bicamada depositada aproximadamente a mesma quantidade de material é imobilizado. A interação entre os grupos sulfônicos e o anel piridínio é a responsável pela sustentação dos filmes, devido ao deslocamento da banda associada à vibração dos grupos sulfônicos. O filme (SiPy+Cl-/CuTsPc)5 mostrou propriedades eletrocatalíticas na determinação de PMZ. Este apresentou dois processos de oxidação em 0,48 e 0,79 V. Após a otimização dos parâmetros da voltametria de onda quadrada (f = 100 s-1, a = 40 mV e ΔEs = 2 mV), o pico a 0,79 V foi utilizado para sua quantificação. Nestas condições, o eletrodo modificado obteve uma resposta linear de 3,98 x10-7 a 3,85 x 10-6 mol L-1 com limites de detecção (LD) e quantificação (LQ) iguais a 8,71 x 10-9 mol L-1 (2,79 μg L-1) e 9,31 x 10-8 mol L-1 (9,31 μg L-1), respectivamente. A recuperação em amostras farmacêuticas revelou alta estabilidade, especificidade e precisão do método, sem qualquer pré-tratamento. O filme (SiPy+Cl-/CuTsPc)2 demonstrou excelente atividade eletrocatalítica para redução de H2O2 com uma ampla resposta linear (4,97 x 10-6 a 4,76 x 10-5 mol L-1) e baixo limite de detecção (0,33 x 10-6 mol L-1). Este eletrodo foi modificado com a enzima glicose oxidase (GOx) e recoberto com filme de Nafion® (Nf), que foi usado para prevenir o lixiviamento da GOx. As técnicas espectroscópicas de infravermelho, fluorescência e dicroísmo circular mostraram que a enzima GOx mantém a sua estrutura nativa secundária quando imobilizado sobre o filme LbL. O biossensor resultante (SiPy+Cl-/CuTsPc)2(SiPy+Cl-/GOx/Nf) exibiu uma resposta de corrente que variou linearmente com a concentração de glicose na faixa de 1 a 10 mmol L-1, com LD = 0,17 mmol L-1, sensibilidade de 1,397 x 10-7 μA/mmol L-1 e um rápido tempo de resposta, inferior a 5 s. A constante de Michaelis-Menten aparente ( appmK ) foi de 10 mmol L-1. Além disso, o biossensor também apresentou boa reprodutibilidade, excelente estabilidade e longo tempo de vida, sem diminuição da atividade enzimática por um período de uma semana e permaneceu ativo por mais de três semanas. A utilização do polímero Nf possibilitou a diminuição do efeito de interferentes na resposta do biossensor. Palavras chave: Filmes LbL, polieletrólito Silsesquioxano, Biossensor Amperométrico, Glicose Oxidase. 2017-07-20T12:40:21Z 2013-10-11 2017-07-20T12:40:21Z 2013-06-21 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis JESUS, Cliciane Guadalupe de. SENSORES ELETROQUÍMICOS BASEADOS EM FILMES LBL DE FTALOCIANINA METALADA E POLÍMERO SILSESQUIOXANO.. 2013. 106 f. Tese (Doutorado em Físico Química, Química Analitica, Química Organica, Química Inorgânica) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2013. http://tede2.uepg.br/jspui/handle/prefix/14 por info:eu-repo/semantics/openAccess application/pdf UNIVERSIDADE ESTADUAL DE PONTA GROSSA Programa Associado de Pós-Graduação em Química - Doutorado UEPG BR Físico Química, Química Analitica, Química Organica, Química Inorgânica reponame:Biblioteca Digital de Teses e Dissertações da UEPG instname:Universidade Estadual de Ponta Grossa instacron:UEPG