Emissivity Profiles at TCABR Tokamak

The determination of plasma equilibrium profiles is necessary to evaluate the properties of the confinement and to investigate perturbation effects. Optical diagnostics can be used to determine some of these profiles. However, these diagnostics measure all emitted radiation at a solid angle that...

Full description

Bibliographic Details
Main Author: Alexandre Machado de Oliveira
Other Authors: Zwinglio de Oliveira Guimarães Filho
Language:English
Published: Universidade de São Paulo 2017
Subjects:
Online Access:http://www.teses.usp.br/teses/disponiveis/43/43134/tde-05092017-154738/
id ndltd-IBICT-oai-teses.usp.br-tde-05092017-154738
record_format oai_dc
collection NDLTD
language English
sources NDLTD
topic Física de Plasmas
Física Óptica
Radiação
Radon
Tokamaks
Optical Physics
Plasma Physics
Radiation
Radon
Tokamaks
spellingShingle Física de Plasmas
Física Óptica
Radiação
Radon
Tokamaks
Optical Physics
Plasma Physics
Radiation
Radon
Tokamaks
Alexandre Machado de Oliveira
Emissivity Profiles at TCABR Tokamak
description The determination of plasma equilibrium profiles is necessary to evaluate the properties of the confinement and to investigate perturbation effects. Optical diagnostics can be used to determine some of these profiles. However, these diagnostics measure all emitted radiation at a solid angle that illuminate each diagnostic channel through a slit. Therefore, the real measured quantity is the emissivity integrated along the line-of-sight and some unfolding procedure, like Abels inversion, is commonly used to recover the emissivity profile. In TCABR tokamak, at the Physics Institute of the University of São Paulo, a 24-channel bolometer and a 20-channel soft X-ray optical diagnostics are used to measure the plasma emissivity in wavelength range from 1.0 to 1000 nm, depending on the used filters. In this work, a numerical simulation is used to compute the signal measured by the diagnostics for a given emissivity profile, allowing direct comparison with the experimental data and avoiding the use of the Abel\'s inversion directly and the numerical difficulties associated with unfolding procedures. By considering TCABR tokamak geometry, spatial coordinates can be related to the normalized linear coordinates of the plasma by imposing a plasma emissivity model that depends on some free parameters, allowing the emissivity resulting in each point can be calculated. Thus, the luminosity of each channel is calculated by the integral of the emissivity modeled in each line-of-sight (Radon Transformation). Emissivity model free parameters are determined by fitting calculated luminosity to measured one. We considered three types of emissivity profiles: a parabolic model in law of power, a Gaussian model and a model based on Bessel functions. We observed that the parabolic profile fits well the bolometer data, while the Gaussian profile is adequate to describe the data obtained with the soft X-ray detector. === A determinação dos perfis de equilíbrio do plasma é necessária para avaliar as propriedades do confinamento e para investigar os efeitos de perturbações. Diagnósticos ópticos podem ser usados para determinar alguns desses perfis. No entanto, esses diagnósticos medem toda a radiação luminosa emitida em um ângulo sólido que ilumina cada canal do detector através de uma fenda. Assim, a verdadeira grandeza física medida é a emissividade integrada ao longo da linha de visada. Com isso, algum procedimento de deconvolução, como a inversão de Abel, se faz necessário para obter o perfil de emissividade. No tokamak TCABR do Instituto de Física da USP, um bolômetro de 24 canais e um detector de raios-X moles de 20 canais são utilizados para medir a emissividade do plasma no intervalo de comprimento de onda de 1 a 1.000 nm, dependendo dos filtros utilizados. Neste trabalho, uma simulação numérica é usada para calcular o sinal medido pelos diagnósticos para um dado perfil de emissividade, possibilitando a comparação direta com os dados experimentais, evitando a realização da inversão de Abel e os problemas numéricos associados aos procedimentos de deconvolução. Pela consideração da geometria do tokamak TCABR, as coordenadas espaciais podem ser relacionadas com as coordenadas lineares normalizadas do plasma por meio da imposição de um modelo de emissividade para o plasma que dependa de alguns parâmetros livres, permitindo que a emissividade resultante em cada ponto possa ser calculada. Assim, a luminosidade de cada canal é calculada pela integral da emissividade modelada em cada linha de visada (Transformada de Radon). Os parâmetros livres dos perfis de emissividade são determinados ajustando-se as luminosidades calculadas em termos das luminosidades medidas. Nós consideramos três modelos de perfis de emissividade: um modelo parabólico em lei de potência, um modelo gaussiano e um modelo baseado em funções de Bessel. Observamos que o perfil parabólico ajusta-se bem aos dados do bolômetro, ao passo que o perfil gaussiano é adequado para descrever os dados obtidos com o detector de raios-X moles.
author2 Zwinglio de Oliveira Guimarães Filho
author_facet Zwinglio de Oliveira Guimarães Filho
Alexandre Machado de Oliveira
author Alexandre Machado de Oliveira
author_sort Alexandre Machado de Oliveira
title Emissivity Profiles at TCABR Tokamak
title_short Emissivity Profiles at TCABR Tokamak
title_full Emissivity Profiles at TCABR Tokamak
title_fullStr Emissivity Profiles at TCABR Tokamak
title_full_unstemmed Emissivity Profiles at TCABR Tokamak
title_sort emissivity profiles at tcabr tokamak
publisher Universidade de São Paulo
publishDate 2017
url http://www.teses.usp.br/teses/disponiveis/43/43134/tde-05092017-154738/
work_keys_str_mv AT alexandremachadodeoliveira emissivityprofilesattcabrtokamak
AT alexandremachadodeoliveira perfisdeemissividadenotokamaktcabr
_version_ 1718932592877633536
spelling ndltd-IBICT-oai-teses.usp.br-tde-05092017-1547382019-01-22T01:15:44Z Emissivity Profiles at TCABR Tokamak Perfis de Emissividade no Tokamak TCABR Alexandre Machado de Oliveira Zwinglio de Oliveira Guimarães Filho Maria Celia Ramos de Andrade Ibere Luiz Caldas Física de Plasmas Física Óptica Radiação Radon Tokamaks Optical Physics Plasma Physics Radiation Radon Tokamaks The determination of plasma equilibrium profiles is necessary to evaluate the properties of the confinement and to investigate perturbation effects. Optical diagnostics can be used to determine some of these profiles. However, these diagnostics measure all emitted radiation at a solid angle that illuminate each diagnostic channel through a slit. Therefore, the real measured quantity is the emissivity integrated along the line-of-sight and some unfolding procedure, like Abels inversion, is commonly used to recover the emissivity profile. In TCABR tokamak, at the Physics Institute of the University of São Paulo, a 24-channel bolometer and a 20-channel soft X-ray optical diagnostics are used to measure the plasma emissivity in wavelength range from 1.0 to 1000 nm, depending on the used filters. In this work, a numerical simulation is used to compute the signal measured by the diagnostics for a given emissivity profile, allowing direct comparison with the experimental data and avoiding the use of the Abel\'s inversion directly and the numerical difficulties associated with unfolding procedures. By considering TCABR tokamak geometry, spatial coordinates can be related to the normalized linear coordinates of the plasma by imposing a plasma emissivity model that depends on some free parameters, allowing the emissivity resulting in each point can be calculated. Thus, the luminosity of each channel is calculated by the integral of the emissivity modeled in each line-of-sight (Radon Transformation). Emissivity model free parameters are determined by fitting calculated luminosity to measured one. We considered three types of emissivity profiles: a parabolic model in law of power, a Gaussian model and a model based on Bessel functions. We observed that the parabolic profile fits well the bolometer data, while the Gaussian profile is adequate to describe the data obtained with the soft X-ray detector. A determinação dos perfis de equilíbrio do plasma é necessária para avaliar as propriedades do confinamento e para investigar os efeitos de perturbações. Diagnósticos ópticos podem ser usados para determinar alguns desses perfis. No entanto, esses diagnósticos medem toda a radiação luminosa emitida em um ângulo sólido que ilumina cada canal do detector através de uma fenda. Assim, a verdadeira grandeza física medida é a emissividade integrada ao longo da linha de visada. Com isso, algum procedimento de deconvolução, como a inversão de Abel, se faz necessário para obter o perfil de emissividade. No tokamak TCABR do Instituto de Física da USP, um bolômetro de 24 canais e um detector de raios-X moles de 20 canais são utilizados para medir a emissividade do plasma no intervalo de comprimento de onda de 1 a 1.000 nm, dependendo dos filtros utilizados. Neste trabalho, uma simulação numérica é usada para calcular o sinal medido pelos diagnósticos para um dado perfil de emissividade, possibilitando a comparação direta com os dados experimentais, evitando a realização da inversão de Abel e os problemas numéricos associados aos procedimentos de deconvolução. Pela consideração da geometria do tokamak TCABR, as coordenadas espaciais podem ser relacionadas com as coordenadas lineares normalizadas do plasma por meio da imposição de um modelo de emissividade para o plasma que dependa de alguns parâmetros livres, permitindo que a emissividade resultante em cada ponto possa ser calculada. Assim, a luminosidade de cada canal é calculada pela integral da emissividade modelada em cada linha de visada (Transformada de Radon). Os parâmetros livres dos perfis de emissividade são determinados ajustando-se as luminosidades calculadas em termos das luminosidades medidas. Nós consideramos três modelos de perfis de emissividade: um modelo parabólico em lei de potência, um modelo gaussiano e um modelo baseado em funções de Bessel. Observamos que o perfil parabólico ajusta-se bem aos dados do bolômetro, ao passo que o perfil gaussiano é adequado para descrever os dados obtidos com o detector de raios-X moles. 2017-06-02 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://www.teses.usp.br/teses/disponiveis/43/43134/tde-05092017-154738/ eng info:eu-repo/semantics/openAccess Universidade de São Paulo Física USP BR reponame:Biblioteca Digital de Teses e Dissertações da USP instname:Universidade de São Paulo instacron:USP