Projeto e simulação de filtros L e LCL para interconexão de inversor NPC trifásico à rede

ARAÚJO, R. D. Projeto e simulação de filtros L e LCL para interconexão de inversor NPC trifásico à rede. 2012. 116 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. === Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-17T1...

Full description

Bibliographic Details
Main Author: Araújo, Rômulo Diniz
Other Authors: Antunes, Fernando Luiz Marcelo
Language:Portuguese
Published: 2012
Subjects:
Online Access:http://www.repositorio.ufc.br/handle/riufc/3812
Description
Summary:ARAÚJO, R. D. Projeto e simulação de filtros L e LCL para interconexão de inversor NPC trifásico à rede. 2012. 116 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. === Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-17T13:29:57Z No. of bitstreams: 1 2012_dis_rdaraujo.pdf: 4251419 bytes, checksum: f27bc25f9ec9ed55ba97ff7ec72e17fd (MD5) === Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T18:13:12Z (GMT) No. of bitstreams: 1 2012_dis_rdaraujo.pdf: 4251419 bytes, checksum: f27bc25f9ec9ed55ba97ff7ec72e17fd (MD5) === Made available in DSpace on 2012-09-25T18:13:12Z (GMT). No. of bitstreams: 1 2012_dis_rdaraujo.pdf: 4251419 bytes, checksum: f27bc25f9ec9ed55ba97ff7ec72e17fd (MD5) Previous issue date: 2012-03 === This paper presents the study of a 6 kW, 380 V, three phase NPC inverter for interconnecting distributed generation unit to the grid. The inverter is studied with switching frequency of 3, 4 and 6 kHz, and it is interconnected to the grid through L and LCL filters. To identify which passive filter, L or LCL, is best suited to the inverter under study, a mathematical model has been proposed and several numerical simulations have been carried out to validate the design of the inverter and vector model developed. The control response is satisfactory, since the inverter is able to control the flow of active and reactive power delivered to the grid. Based on these results it was noticed that the LCL filter showed a lower harmonic content for the three frequencies studied in relation to the filter L. Both filters met the requirements of the standard IEEE Std 1543, however the filter L is the most suitable for the inverter under study, because the filter L not only meet the standard but also it presents a lower cost when compared to the LCL filter. === Este trabalho apresenta o estudo de um inversor NPC de 6 kW e 380 V, trifásico, para interconexão de sistemas de geração distribuída à rede elétrica. O inversor é estudado nas frequências de chaveamento de 3, 4 e 6 kHz, sendo interligado à rede elétrica através dos filtros L e LCL. Para identificar qual filtro passivo, L ou LCL, se adequa melhor ao inversor em estudo foram realizadas simulações numéricas para diferentes situações, validando o projeto do inversor e a modelagem vetorial desenvolvida. A resposta do controle é satisfatória, pois o inversor é capaz de controlar o fluxo de potência ativa e reativa entregues à rede elétrica. Diante dos resultados obtidos percebeu-se que o filtro LCL apresentou um menor conteúdo harmônico para as três frequências estudadas em relação ao filtro L. Ambos os filtros atenderam aos requisitos da norma Std IEEE 1543, no entanto o filtro L é o mais indicado para o inversor em estudo, pois além de atender a norma, o mesmo apresenta um menor custo quando comparado ao filtro LCL.