Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges

The subject of this research program was to investigate the behaviour of a unique hybrid bridge girder under various types of loading. The hybrid girder was made up of a reinforced concrete web with steel flange plates connected to the top and bottom using steel headed shear studs. This system is...

Full description

Bibliographic Details
Main Author: Van Leeuwen, Joost
Language:English
Published: 2009
Online Access:http://hdl.handle.net/2429/4263
id ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-4263
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-42632014-03-14T15:39:24Z Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges Van Leeuwen, Joost The subject of this research program was to investigate the behaviour of a unique hybrid bridge girder under various types of loading. The hybrid girder was made up of a reinforced concrete web with steel flange plates connected to the top and bottom using steel headed shear studs. This system is known under its commercial name as "COMPO-GIRDER.™" The research program was divided in two phases. In Phase I, 20 half-scale elements were tested under shear dominated loading in a special element tester (Adebar, 1991). The objective was to investigate the interaction of horizontal and vertical shear strengths. Numerous shear failure modes were observed during the tests. The measured shear strengths were compared with the predicted shear capacities using the design provisions in the CAN/CSA-S6-88 code and the draft CHBDC code. The comparisons indicated that the code design provisions were appropriate for both the horizontal and vertical shear design of the hybrid girder elements. One full-scale bridge specimen was tested in Phase II and consisted of a hybrid girder with concrete deck panels compositely attached to it. The simply supported bridge specimen was subjected to two equal point loads at the third points. The behaviour of the test specimen was studied under service loads and increasing load until failure. Many aspects of the bridge test specimen behaviour were investigated. Perhaps the most important one was the extent of cracking in the girder under service loads. Crack widths measured at the service load level were found to meet the CEB-FJP code limits for a "Moderate" environment and the BS 5400 limits for a "Severe" environment. 2009-02-06T22:44:05Z 2009-02-06T22:44:05Z 1996 2009-02-06T22:44:05Z 1996-05 Electronic Thesis or Dissertation http://hdl.handle.net/2429/4263 eng UBC Retrospective Theses Digitization Project [http://www.library.ubc.ca/archives/retro_theses/]
collection NDLTD
language English
sources NDLTD
description The subject of this research program was to investigate the behaviour of a unique hybrid bridge girder under various types of loading. The hybrid girder was made up of a reinforced concrete web with steel flange plates connected to the top and bottom using steel headed shear studs. This system is known under its commercial name as "COMPO-GIRDER.™" The research program was divided in two phases. In Phase I, 20 half-scale elements were tested under shear dominated loading in a special element tester (Adebar, 1991). The objective was to investigate the interaction of horizontal and vertical shear strengths. Numerous shear failure modes were observed during the tests. The measured shear strengths were compared with the predicted shear capacities using the design provisions in the CAN/CSA-S6-88 code and the draft CHBDC code. The comparisons indicated that the code design provisions were appropriate for both the horizontal and vertical shear design of the hybrid girder elements. One full-scale bridge specimen was tested in Phase II and consisted of a hybrid girder with concrete deck panels compositely attached to it. The simply supported bridge specimen was subjected to two equal point loads at the third points. The behaviour of the test specimen was studied under service loads and increasing load until failure. Many aspects of the bridge test specimen behaviour were investigated. Perhaps the most important one was the extent of cracking in the girder under service loads. Crack widths measured at the service load level were found to meet the CEB-FJP code limits for a "Moderate" environment and the BS 5400 limits for a "Severe" environment.
author Van Leeuwen, Joost
spellingShingle Van Leeuwen, Joost
Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
author_facet Van Leeuwen, Joost
author_sort Van Leeuwen, Joost
title Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
title_short Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
title_full Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
title_fullStr Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
title_full_unstemmed Investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
title_sort investigation of a hybrid bridge girder with reinforced concrete web and steel flanges
publishDate 2009
url http://hdl.handle.net/2429/4263
work_keys_str_mv AT vanleeuwenjoost investigationofahybridbridgegirderwithreinforcedconcretewebandsteelflanges
_version_ 1716650305846771712