Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems
Geiger-mode avalanche photodiodes, or silicon photomultipliers, are promising light sensors for the next generation Positron Emission Tomography (PET) scanners. The sensor is being used in the scanner’s gamma ray detector to measure scintillation light. This thesis describes the test results of thre...
Main Author: | |
---|---|
Other Authors: | |
Published: |
Institute of Electrical and Electronics Engineers
2013
|
Subjects: | |
Online Access: | http://hdl.handle.net/1993/18339 |
id |
ndltd-MANITOBA-oai-mspace.lib.umanitoba.ca-1993-18339 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MANITOBA-oai-mspace.lib.umanitoba.ca-1993-183392014-01-31T03:37:28Z Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems Liu, Chen-Yi Goertzen, Andrew (Physics & Astronomy) Fiege, Jason (Physics and Astronomy) Lin, Francis (Physics and Astronomy) Major, Arkady (Electrical and Computer Engineering) positron emission tomography Geiger-mode avalanche photodiodes, or silicon photomultipliers, are promising light sensors for the next generation Positron Emission Tomography (PET) scanners. The sensor is being used in the scanner’s gamma ray detector to measure scintillation light. This thesis describes the test results of three gamma ray detectors that utilize silicon photomultipliers. The first one is a commercial detector, and the other two are custom made. The detectors are tested for their 511 keV photon energy and timing resolution, as well as their ability to measure light from small scintillator crystals. The two custom made detectors had smaller active area, but outperformed the commercial detector in energy resolution. The introduction of buffer amplifiers improved the timing resolution of one detector. All three detectors had their crystal decoding ability limited by signal multiplexing and the sensor’s dark noise. Finally, a detector design was proposed for the PET system being developed in our group. 2013-04-04T14:30:32Z 2013-04-04T14:30:32Z 2011-10-29 C.-Y. Liu and A. Goertzen, “Evaluation of the SensL SPMMatrix for use as a detector for PET and gamma camera applications,” 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, 2011. http://hdl.handle.net/1993/18339 Institute of Electrical and Electronics Engineers |
collection |
NDLTD |
sources |
NDLTD |
topic |
positron emission tomography |
spellingShingle |
positron emission tomography Liu, Chen-Yi Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
description |
Geiger-mode avalanche photodiodes, or silicon photomultipliers, are promising light sensors for the next generation Positron Emission Tomography (PET) scanners. The sensor is being used in the scanner’s gamma ray detector to measure scintillation light. This thesis describes the test results of three gamma ray detectors that utilize silicon photomultipliers. The first one is a commercial detector, and the other two are custom made. The detectors are tested for their 511 keV photon energy and timing resolution, as well as their ability to measure light from small scintillator crystals. The two custom made detectors had smaller active area, but outperformed the commercial detector in energy resolution. The introduction of buffer amplifiers improved the timing resolution of one detector. All three detectors had their crystal decoding ability limited by signal multiplexing and the sensor’s dark noise. Finally, a detector design was proposed for the PET system being developed in our group. |
author2 |
Goertzen, Andrew (Physics & Astronomy) |
author_facet |
Goertzen, Andrew (Physics & Astronomy) Liu, Chen-Yi |
author |
Liu, Chen-Yi |
author_sort |
Liu, Chen-Yi |
title |
Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
title_short |
Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
title_full |
Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
title_fullStr |
Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
title_full_unstemmed |
Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
title_sort |
characterization of silicon photomultiplier readout designs for use in positron emission tomography systems |
publisher |
Institute of Electrical and Electronics Engineers |
publishDate |
2013 |
url |
http://hdl.handle.net/1993/18339 |
work_keys_str_mv |
AT liuchenyi characterizationofsiliconphotomultiplierreadoutdesignsforuseinpositronemissiontomographysystems |
_version_ |
1716632029521510400 |