Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions

Thesis: Ph. D., Harvard-MIT Program in Health Sciences and Technology, 2018. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 156-175). === Organ transplantation is a valuable treatment for organ failure; however, it is limited by an increasing shortage of don...

Full description

Bibliographic Details
Main Author: Chang, Brian Yale
Other Authors: Elazer R. Edelman.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2018
Subjects:
Online Access:http://hdl.handle.net/1721.1/118030
id ndltd-MIT-oai-dspace.mit.edu-1721.1-118030
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-1180302019-05-02T16:22:36Z Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions Chang, Brian Yale Elazer R. Edelman. Harvard--MIT Program in Health Sciences and Technology. Harvard--MIT Program in Health Sciences and Technology. Harvard--MIT Program in Health Sciences and Technology. Thesis: Ph. D., Harvard-MIT Program in Health Sciences and Technology, 2018. Cataloged from PDF version of thesis. Includes bibliographical references (pages 156-175). Organ transplantation is a valuable treatment for organ failure; however, it is limited by an increasing shortage of donor organs. Because of this, mechanical support has emerged as an effective therapy to promote recovery of native organ function, especially in the setting of acute heart failure. Acute heart failure is increasingly prominent and inadequately treated by traditional medical therapy. Mechanical circulatory support (MCS) devices unload the heart by offering a range of support that reduces mortality and promotes cardiac recovery when correctly used. The challenge in use of these devices is the lack of metric-driven control for the level of support currently manually determined by a clinician. We hypothesize that optimization of device use requires novel insights in physiology and definition of organ state through an understanding of device-organ interconnectivity in support devices that are coupled with residual organ function. Thus, the goals of this work are to leverage the interaction between support device and organ to assess the state of the organ and then use this information towards improved device control and understanding of organ pathophysiology. The research program used an integrated approach of bench-top testing, animal models, and retrospective patient data to determine advanced markers of cardiac function using the Abiomed Impella as a paradigmatic device. We developed a mock circulatory loop to identify how MCS devices operate over the cardiac cycle during changing cardiovascular states. Parametric analysis revealed a hysteretic state-responsive relationship between the device and subject physiology. Since device operation is characterized using the MCL, unaccounted hysteresis changes can be attributed to variation in the cardiac state. We utilized this model to predict novel metrics of cardiac dynamics and easily-validated parameters of cardiac state in both acute animal models and retrospective patient data in which we accurately differentiated disease states and clinical outcomes. Finally, we investigated how MCS can affect downstream vascular response in animals and patients by analyzing arterial pressure waveforms with known device performance to quantify vascular state and device-vascular coupling. by Brian Yale Chang. Ph. D. 2018-09-17T15:54:31Z 2018-09-17T15:54:31Z 2018 2018 Thesis http://hdl.handle.net/1721.1/118030 1051458643 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 175 pages application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Harvard--MIT Program in Health Sciences and Technology.
spellingShingle Harvard--MIT Program in Health Sciences and Technology.
Chang, Brian Yale
Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
description Thesis: Ph. D., Harvard-MIT Program in Health Sciences and Technology, 2018. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 156-175). === Organ transplantation is a valuable treatment for organ failure; however, it is limited by an increasing shortage of donor organs. Because of this, mechanical support has emerged as an effective therapy to promote recovery of native organ function, especially in the setting of acute heart failure. Acute heart failure is increasingly prominent and inadequately treated by traditional medical therapy. Mechanical circulatory support (MCS) devices unload the heart by offering a range of support that reduces mortality and promotes cardiac recovery when correctly used. The challenge in use of these devices is the lack of metric-driven control for the level of support currently manually determined by a clinician. We hypothesize that optimization of device use requires novel insights in physiology and definition of organ state through an understanding of device-organ interconnectivity in support devices that are coupled with residual organ function. Thus, the goals of this work are to leverage the interaction between support device and organ to assess the state of the organ and then use this information towards improved device control and understanding of organ pathophysiology. The research program used an integrated approach of bench-top testing, animal models, and retrospective patient data to determine advanced markers of cardiac function using the Abiomed Impella as a paradigmatic device. We developed a mock circulatory loop to identify how MCS devices operate over the cardiac cycle during changing cardiovascular states. Parametric analysis revealed a hysteretic state-responsive relationship between the device and subject physiology. Since device operation is characterized using the MCL, unaccounted hysteresis changes can be attributed to variation in the cardiac state. We utilized this model to predict novel metrics of cardiac dynamics and easily-validated parameters of cardiac state in both acute animal models and retrospective patient data in which we accurately differentiated disease states and clinical outcomes. Finally, we investigated how MCS can affect downstream vascular response in animals and patients by analyzing arterial pressure waveforms with known device performance to quantify vascular state and device-vascular coupling. === by Brian Yale Chang. === Ph. D.
author2 Elazer R. Edelman.
author_facet Elazer R. Edelman.
Chang, Brian Yale
author Chang, Brian Yale
author_sort Chang, Brian Yale
title Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
title_short Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
title_full Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
title_fullStr Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
title_full_unstemmed Determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
title_sort determination of physiologic states during mechanical circulatory support through characterization of device-organ interactions
publisher Massachusetts Institute of Technology
publishDate 2018
url http://hdl.handle.net/1721.1/118030
work_keys_str_mv AT changbrianyale determinationofphysiologicstatesduringmechanicalcirculatorysupportthroughcharacterizationofdeviceorganinteractions
_version_ 1719039224261378048