Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway

Thesis: M. Eng., Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, 2018. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 122-124). === Polyethylene (PE) passive samplers are capable of measuring in-situ, freely dissolve...

Full description

Bibliographic Details
Main Author: Sobchuk, Catherine Elizabeth
Other Authors: E. Eric Adams.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2018
Subjects:
Online Access:http://hdl.handle.net/1721.1/119323
id ndltd-MIT-oai-dspace.mit.edu-1721.1-119323
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-1193232019-05-02T15:59:24Z Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway Sobchuk, Catherine Elizabeth E. Eric Adams. Massachusetts Institute of Technology. Department of Civil and Environmental Engineering. Massachusetts Institute of Technology. Department of Civil and Environmental Engineering. Civil and Environmental Engineering. Thesis: M. Eng., Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, 2018. Cataloged from PDF version of thesis. Includes bibliographical references (pages 122-124). Polyethylene (PE) passive samplers are capable of measuring in-situ, freely dissolved, time-averaged concentration distributions of contaminants in air, surface water, and sediment bed porewater. This sampling technique can be coupled with a three dimensional (3D) hydrodynamic model of a given surface water body to identify where sources contributing to the measured concentration distribution are most likely located and what mass flux is required to produce the measured concentrations. This evaluation was completed for the Lower Duwamish Waterway (LDW), a salt wedge estuary located in Seattle, Washington. The LDW was selected for its idealized conditions (straight channel with relatively uniform cross-section), established 3D hydrodynamic model (Environmental Fluid Dynamics Code [EFDC]), and availability of measured data. Density-driven circulation in the LDW drives saltwater upstream and freshwater downstream, influencing residence times, mixing times, and the resulting concentration distributions of potential sources. The dependence of simulated, unit strength concentration distributions on source location was evaluated by spatially comparing EFDC-simulated sources introduced at various points in the LDW. This determined how far apart potential sources need to be, referred to as a distinguishable distance, to be "resolved" by measured or modeled concentrations at the LDW centerline. East and west bank sources were generally distinguishable within 0.8 miles of introduction; water surface and sediment bed sources were generally distinguishable throughout the LDW; longitudinally distributed sources were distinguishable for 0.4 to 1.1 miles from the source location. PE passive samplers placed at the centerline of the LDW with spacing at or near the distinguishable distance will likely be able to differentiate between various source locations. Inverse model techniques were applied to measured concentration distributions in the water column using numerous cases of potential source locations with distinguishable, unit strength concentration distributions. The resulting mass fluxes ranged from 0.034 mg/s to 0.072 mg/s (average 0.043 mg/s), an order of magnitude higher than known source fluxes (i.e., sediment diffusive flux and air-water exchange flux). Therefore, one or more "missing sources" were determined to exist; based on this evaluation, it is possible the sources originate from the midstream sediment bed, upstream sediment bed, and upstream water surface. by Catherine Elizabeth Sobchuk. M. Eng. 2018-11-28T15:43:11Z 2018-11-28T15:43:11Z 2018 2018 Thesis http://hdl.handle.net/1721.1/119323 1062549016 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 124 pages application/pdf n-us-wa Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Civil and Environmental Engineering.
spellingShingle Civil and Environmental Engineering.
Sobchuk, Catherine Elizabeth
Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway
description Thesis: M. Eng., Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, 2018. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 122-124). === Polyethylene (PE) passive samplers are capable of measuring in-situ, freely dissolved, time-averaged concentration distributions of contaminants in air, surface water, and sediment bed porewater. This sampling technique can be coupled with a three dimensional (3D) hydrodynamic model of a given surface water body to identify where sources contributing to the measured concentration distribution are most likely located and what mass flux is required to produce the measured concentrations. This evaluation was completed for the Lower Duwamish Waterway (LDW), a salt wedge estuary located in Seattle, Washington. The LDW was selected for its idealized conditions (straight channel with relatively uniform cross-section), established 3D hydrodynamic model (Environmental Fluid Dynamics Code [EFDC]), and availability of measured data. Density-driven circulation in the LDW drives saltwater upstream and freshwater downstream, influencing residence times, mixing times, and the resulting concentration distributions of potential sources. The dependence of simulated, unit strength concentration distributions on source location was evaluated by spatially comparing EFDC-simulated sources introduced at various points in the LDW. This determined how far apart potential sources need to be, referred to as a distinguishable distance, to be "resolved" by measured or modeled concentrations at the LDW centerline. East and west bank sources were generally distinguishable within 0.8 miles of introduction; water surface and sediment bed sources were generally distinguishable throughout the LDW; longitudinally distributed sources were distinguishable for 0.4 to 1.1 miles from the source location. PE passive samplers placed at the centerline of the LDW with spacing at or near the distinguishable distance will likely be able to differentiate between various source locations. Inverse model techniques were applied to measured concentration distributions in the water column using numerous cases of potential source locations with distinguishable, unit strength concentration distributions. The resulting mass fluxes ranged from 0.034 mg/s to 0.072 mg/s (average 0.043 mg/s), an order of magnitude higher than known source fluxes (i.e., sediment diffusive flux and air-water exchange flux). Therefore, one or more "missing sources" were determined to exist; based on this evaluation, it is possible the sources originate from the midstream sediment bed, upstream sediment bed, and upstream water surface. === by Catherine Elizabeth Sobchuk. === M. Eng.
author2 E. Eric Adams.
author_facet E. Eric Adams.
Sobchuk, Catherine Elizabeth
author Sobchuk, Catherine Elizabeth
author_sort Sobchuk, Catherine Elizabeth
title Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway
title_short Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway
title_full Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway
title_fullStr Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway
title_full_unstemmed Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway
title_sort evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the lower duwamish waterway
publisher Massachusetts Institute of Technology
publishDate 2018
url http://hdl.handle.net/1721.1/119323
work_keys_str_mv AT sobchukcatherineelizabeth evaluatingthecombineduseofthreedimensionalhydrodynamicmodelingandpolyethylenepassivesamplinginthelowerduwamishwaterway
_version_ 1719032369028005888