A simple criterion for three-dimensional flow separation in axial compressors
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2006. === Includes bibliographical references (p. 104-106). === Most modem blade designs in axial-flow compressors diffuse the flow efficiently over 20% to 80% of blade span and it is the endwall regions t...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2007
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/37567 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-37567 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-375672019-05-02T16:17:26Z A simple criterion for three-dimensional flow separation in axial compressors Lei, Vai-Man Zoltan S. Spakovszky. Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics. Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics. Aeronautics and Astronautics. Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2006. Includes bibliographical references (p. 104-106). Most modem blade designs in axial-flow compressors diffuse the flow efficiently over 20% to 80% of blade span and it is the endwall regions that set the limits in compressor performance. This thesis addresses the estimation, control and mitigation of three-dimensional separation near the hub corner in axial- flow compressors. A simple method to estimate the onset of hub comer separation in compressor blade passages has been developed. A parameter is defined to quantify the combined effect of adverse pressure gradient and secondary flow which are the two main mechanisms contributing to the formation of three-dimensional flow separation. There is a critical value of the parameter at which the onset of three-dimensional flow separation occurs. Data from existing research and production compressors show the generality of the separation criterion. The new parameter captures the alleviating effect of boundary layer skew on three-dimensional flow separation. Using this concept, a flow control scheme has been developed to mitigate hub comer separation by injecting spanwise momentum from the blade suction surface. A proof of concept flow control experiment demonstrates a reduction in stagnation pressure loss coefficient of 8% with an injection flow of 0.8% of the cascade mass flow. by Vai-Man Lei. Ph.D. 2007-05-16T18:59:54Z 2007-05-16T18:59:54Z 2006 2006 Thesis http://hdl.handle.net/1721.1/37567 74670670 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 113 p. application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Aeronautics and Astronautics. |
spellingShingle |
Aeronautics and Astronautics. Lei, Vai-Man A simple criterion for three-dimensional flow separation in axial compressors |
description |
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2006. === Includes bibliographical references (p. 104-106). === Most modem blade designs in axial-flow compressors diffuse the flow efficiently over 20% to 80% of blade span and it is the endwall regions that set the limits in compressor performance. This thesis addresses the estimation, control and mitigation of three-dimensional separation near the hub corner in axial- flow compressors. A simple method to estimate the onset of hub comer separation in compressor blade passages has been developed. A parameter is defined to quantify the combined effect of adverse pressure gradient and secondary flow which are the two main mechanisms contributing to the formation of three-dimensional flow separation. There is a critical value of the parameter at which the onset of three-dimensional flow separation occurs. Data from existing research and production compressors show the generality of the separation criterion. The new parameter captures the alleviating effect of boundary layer skew on three-dimensional flow separation. Using this concept, a flow control scheme has been developed to mitigate hub comer separation by injecting spanwise momentum from the blade suction surface. A proof of concept flow control experiment demonstrates a reduction in stagnation pressure loss coefficient of 8% with an injection flow of 0.8% of the cascade mass flow. === by Vai-Man Lei. === Ph.D. |
author2 |
Zoltan S. Spakovszky. |
author_facet |
Zoltan S. Spakovszky. Lei, Vai-Man |
author |
Lei, Vai-Man |
author_sort |
Lei, Vai-Man |
title |
A simple criterion for three-dimensional flow separation in axial compressors |
title_short |
A simple criterion for three-dimensional flow separation in axial compressors |
title_full |
A simple criterion for three-dimensional flow separation in axial compressors |
title_fullStr |
A simple criterion for three-dimensional flow separation in axial compressors |
title_full_unstemmed |
A simple criterion for three-dimensional flow separation in axial compressors |
title_sort |
simple criterion for three-dimensional flow separation in axial compressors |
publisher |
Massachusetts Institute of Technology |
publishDate |
2007 |
url |
http://hdl.handle.net/1721.1/37567 |
work_keys_str_mv |
AT leivaiman asimplecriterionforthreedimensionalflowseparationinaxialcompressors AT leivaiman simplecriterionforthreedimensionalflowseparationinaxialcompressors |
_version_ |
1719037881069076480 |