Thermal properties of advanced aerogel insulation

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 74-76). === Buildings consume too much energy. For example, 16.6% of all the energy used in the United States goes toward...

Full description

Bibliographic Details
Main Author: Cohen, Ellann
Other Authors: Leon Glicksman.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2011
Subjects:
Online Access:http://hdl.handle.net/1721.1/67795
id ndltd-MIT-oai-dspace.mit.edu-1721.1-67795
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-677952019-05-02T16:08:50Z Thermal properties of advanced aerogel insulation Cohen, Ellann Leon Glicksman. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. Cataloged from PDF version of thesis. Includes bibliographical references (p. 74-76). Buildings consume too much energy. For example, 16.6% of all the energy used in the United States goes towards just the heating and cooling of buildings. Many governments, organizations, and companies are setting very ambitious goals to reduce their energy use over the next few years. Because the time periods for these goals are much less than the average lifetime of a building, existing buildings will need to be retrofitted. There are two different types of retrofitting: shallow and deep. Shallow retrofits involve the quickest and least expensive improvements often including reducing infiltration around windows, under doors, etc and blowing more insulation into the attic. Deep retrofits are those that involve costly renovation and typically include adding insulation to the walls and replacing windows. A new, easily installable, inexpensive, and thin insulation would move insulating the walls from the deep retrofit category to the shallow retrofit category and thus would revolutionize the process of retrofitting homes to make them more energy efficient. This thesis provides an overview of a concept for a new, easily installable, inexpensive, thin aerogel-based insulation and goes into detail on how the thermal properties of the aerogel were measured and validated. The transient hot-wire method for measuring the thermal conductivity of very low thermal conductivity silica aerogel (1 0mW/m K at 1 atm) along with a correction for end effects was validated with the NIST (National Institute of Standards and Technology) Standard Reference Material 1459, fumed silica board to within 1 mW/mK. Despite the translucence of the aerogel at certain wavelengths, radiation is not an issue through the aerogel during the hot-wire test but may be an issue in actual use as an insulation. The monolithic aerogel thermal conductivity drops significantly with slightly reduced pressure (3.2 mW/m K at 0.1atm). For the final composite insulation, the new silica aerogel formula is a great choice and it is recommended to reduce the pressure around the aerogel to 1 / 1 0 th. In the future, a prototype of an insulation panel combining a 3-D truss structure, monolithic or granular silica aerogel, and reduced pressure will be constructed and tested. by Ellann Cohen. S.M. 2011-12-19T18:52:19Z 2011-12-19T18:52:19Z 2011 2011 Thesis http://hdl.handle.net/1721.1/67795 767826078 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 79 p. application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Mechanical Engineering.
spellingShingle Mechanical Engineering.
Cohen, Ellann
Thermal properties of advanced aerogel insulation
description Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 74-76). === Buildings consume too much energy. For example, 16.6% of all the energy used in the United States goes towards just the heating and cooling of buildings. Many governments, organizations, and companies are setting very ambitious goals to reduce their energy use over the next few years. Because the time periods for these goals are much less than the average lifetime of a building, existing buildings will need to be retrofitted. There are two different types of retrofitting: shallow and deep. Shallow retrofits involve the quickest and least expensive improvements often including reducing infiltration around windows, under doors, etc and blowing more insulation into the attic. Deep retrofits are those that involve costly renovation and typically include adding insulation to the walls and replacing windows. A new, easily installable, inexpensive, and thin insulation would move insulating the walls from the deep retrofit category to the shallow retrofit category and thus would revolutionize the process of retrofitting homes to make them more energy efficient. This thesis provides an overview of a concept for a new, easily installable, inexpensive, thin aerogel-based insulation and goes into detail on how the thermal properties of the aerogel were measured and validated. The transient hot-wire method for measuring the thermal conductivity of very low thermal conductivity silica aerogel (1 0mW/m K at 1 atm) along with a correction for end effects was validated with the NIST (National Institute of Standards and Technology) Standard Reference Material 1459, fumed silica board to within 1 mW/mK. Despite the translucence of the aerogel at certain wavelengths, radiation is not an issue through the aerogel during the hot-wire test but may be an issue in actual use as an insulation. The monolithic aerogel thermal conductivity drops significantly with slightly reduced pressure (3.2 mW/m K at 0.1atm). For the final composite insulation, the new silica aerogel formula is a great choice and it is recommended to reduce the pressure around the aerogel to 1 / 1 0 th. In the future, a prototype of an insulation panel combining a 3-D truss structure, monolithic or granular silica aerogel, and reduced pressure will be constructed and tested. === by Ellann Cohen. === S.M.
author2 Leon Glicksman.
author_facet Leon Glicksman.
Cohen, Ellann
author Cohen, Ellann
author_sort Cohen, Ellann
title Thermal properties of advanced aerogel insulation
title_short Thermal properties of advanced aerogel insulation
title_full Thermal properties of advanced aerogel insulation
title_fullStr Thermal properties of advanced aerogel insulation
title_full_unstemmed Thermal properties of advanced aerogel insulation
title_sort thermal properties of advanced aerogel insulation
publisher Massachusetts Institute of Technology
publishDate 2011
url http://hdl.handle.net/1721.1/67795
work_keys_str_mv AT cohenellann thermalpropertiesofadvancedaerogelinsulation
_version_ 1719035375879454720