A passive cooling design for multifamily residences [sic] in hot, humid climates

Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1983. === MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH === Includes bibliographical references (leaves 159-160). === People living in hot, humid climates suffer either from extremely uncomfortable weather conditions or f...

Full description

Bibliographic Details
Main Author: Tang, Joseph C
Other Authors: Timothy Johnson.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2013
Subjects:
Online Access:http://hdl.handle.net/1721.1/78051
id ndltd-MIT-oai-dspace.mit.edu-1721.1-78051
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-780512019-05-02T15:42:08Z A passive cooling design for multifamily residences [sic] in hot, humid climates Passive cooling design for multifamily residences in hot, humid climates Tang, Joseph C Timothy Johnson. Massachusetts Institute of Technology. Dept. of Architecture. Massachusetts Institute of Technology. Dept. of Architecture. Architecture. Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1983. MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH Includes bibliographical references (leaves 159-160). People living in hot, humid climates suffer either from extremely uncomfortable weather conditions or from the great cost of air-conditioning systems for maintaining comfort. Most of the available passive cooling techniques which are applicable to other climates have been proven to be ineffective in hot, humid climates. This thesis examines the available passive cooling techniques and describes their potential and limitations . This thesis also proposes a series of passive cooling design solutions for the multifamily residences found in hot, humid climates like Taipei. In addition, a low-cost cooling system is developed as a substitute for conventional high-cost air-conditioning systems, to be used during periods when passive means are incapable of maintaining human comfort. This newly proposed system employs a seasonal cooling reservoir coupled to a heat pump DHW heater. The continuous heat extraction from the cooling reservoir for DHW needs makes the reservoir an effective cooling resource in the summer. by Joseph C. Tang. M.S. 2013-03-28T17:57:08Z 2013-03-28T17:57:08Z 1983 1983 Thesis http://hdl.handle.net/1721.1/78051 11479773 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 160 [i.e. 161] leaves application/pdf a-ch--- Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Architecture.
spellingShingle Architecture.
Tang, Joseph C
A passive cooling design for multifamily residences [sic] in hot, humid climates
description Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1983. === MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH === Includes bibliographical references (leaves 159-160). === People living in hot, humid climates suffer either from extremely uncomfortable weather conditions or from the great cost of air-conditioning systems for maintaining comfort. Most of the available passive cooling techniques which are applicable to other climates have been proven to be ineffective in hot, humid climates. This thesis examines the available passive cooling techniques and describes their potential and limitations . This thesis also proposes a series of passive cooling design solutions for the multifamily residences found in hot, humid climates like Taipei. In addition, a low-cost cooling system is developed as a substitute for conventional high-cost air-conditioning systems, to be used during periods when passive means are incapable of maintaining human comfort. This newly proposed system employs a seasonal cooling reservoir coupled to a heat pump DHW heater. The continuous heat extraction from the cooling reservoir for DHW needs makes the reservoir an effective cooling resource in the summer. === by Joseph C. Tang. === M.S.
author2 Timothy Johnson.
author_facet Timothy Johnson.
Tang, Joseph C
author Tang, Joseph C
author_sort Tang, Joseph C
title A passive cooling design for multifamily residences [sic] in hot, humid climates
title_short A passive cooling design for multifamily residences [sic] in hot, humid climates
title_full A passive cooling design for multifamily residences [sic] in hot, humid climates
title_fullStr A passive cooling design for multifamily residences [sic] in hot, humid climates
title_full_unstemmed A passive cooling design for multifamily residences [sic] in hot, humid climates
title_sort passive cooling design for multifamily residences [sic] in hot, humid climates
publisher Massachusetts Institute of Technology
publishDate 2013
url http://hdl.handle.net/1721.1/78051
work_keys_str_mv AT tangjosephc apassivecoolingdesignformultifamilyresidencessicinhothumidclimates
AT tangjosephc passivecoolingdesignformultifamilyresidencesinhothumidclimates
AT tangjosephc passivecoolingdesignformultifamilyresidencessicinhothumidclimates
_version_ 1719026853668192256