Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads

Bibliographic Details
Main Author: Marziale, Stephen
Language:English
Published: University of Dayton / OhioLINK 2014
Subjects:
Online Access:http://rave.ohiolink.edu/etdc/view?acc_num=dayton1407153177
id ndltd-OhioLink-oai-etd.ohiolink.edu-dayton1407153177
record_format oai_dc
spelling ndltd-OhioLink-oai-etd.ohiolink.edu-dayton14071531772021-08-03T06:26:42Z Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads Marziale, Stephen Civil Engineering Engineering brick veneer concrete masonry shear wall in-plane load seismic wall ties flashing Brick veneers are commonplace in modern building construction. Current building codes require veneers to be anchored to a structural backing in order to transfer out-of-plane loads. However, for in-plane loads the code assigns brick veneers as nonparticipating elements. This study utilizes a modified analytical method to examine the in-plane coupling between brick veneers and concrete masonry shear walls. The amount of load transferred through wall ties depends on factors such as tie spacing, tie stiffness, reinforcement, etc. Results indicate that some degrees of composite action exist; around 12 % to 37 % of the applied shear load is transferred to the brick veneer. Veneers should be isolated in their own plane from the seismic-force-resisting system. An optimum location of the isolation joint is proposed to minimize rocking behavior and limit design story drift. 2014-08-26 English text University of Dayton / OhioLINK http://rave.ohiolink.edu/etdc/view?acc_num=dayton1407153177 http://rave.ohiolink.edu/etdc/view?acc_num=dayton1407153177 unrestricted This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
collection NDLTD
language English
sources NDLTD
topic Civil Engineering
Engineering
brick veneer
concrete masonry
shear wall
in-plane load
seismic
wall ties
flashing
spellingShingle Civil Engineering
Engineering
brick veneer
concrete masonry
shear wall
in-plane load
seismic
wall ties
flashing
Marziale, Stephen
Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
author Marziale, Stephen
author_facet Marziale, Stephen
author_sort Marziale, Stephen
title Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
title_short Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
title_full Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
title_fullStr Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
title_full_unstemmed Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
title_sort analysis of brick veneer on concrete masonry wall subjected to in-plane loads
publisher University of Dayton / OhioLINK
publishDate 2014
url http://rave.ohiolink.edu/etdc/view?acc_num=dayton1407153177
work_keys_str_mv AT marzialestephen analysisofbrickveneeronconcretemasonrywallsubjectedtoinplaneloads
_version_ 1719436708034904064