Development of a uric acid biosensing system for haemodialysis waste monitoring
碩士 === 國立臺灣大學 === 電機工程研究所 === 84 === Based on an immobilized uricase reactor and a thick-film hydrogen peroxide platinum electrode, a biosensor for uric acid has been developed in this investigation. The uric acid sensor was combined with a...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1996
|
Online Access: | http://ndltd.ncl.edu.tw/handle/50750350268640075657 |
id |
ndltd-TW-084NTU00442140 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-084NTU004421402016-07-13T04:10:54Z http://ndltd.ncl.edu.tw/handle/50750350268640075657 Development of a uric acid biosensing system for haemodialysis waste monitoring 尿酸生物感測分析系統之研發及其在血液透析廢液監測上之應用 Hu,Yi-Wen 胡以文 碩士 國立臺灣大學 電機工程研究所 84 Based on an immobilized uricase reactor and a thick-film hydrogen peroxide platinum electrode, a biosensor for uric acid has been developed in this investigation. The uric acid sensor was combined with a flow injection analysis system to structure a bioanalytical system for monitoring the uric acid content in the haemodialysis waste. The effect of interferents in the sample had been reduced by modifying the electrode surface with an electropolymerized 1,3-diaminobenzene / resorcinol film. The resulted system could measure uric acid with a linear range from 0.01 to 0.4 mg/dl and sensitivity 97.4nA/mg/dl. The detection limit was 0.01 mg/dl. The correlation coefficient with the clinical photometric method was 0.97. Jan,Gwo-Jen;Hsu,Tien-Tsai 詹國禎;徐添財 1996 學位論文 ; thesis 72 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣大學 === 電機工程研究所 === 84 === Based on an immobilized uricase reactor and a thick-film
hydrogen peroxide platinum electrode, a biosensor for uric acid
has been developed in this investigation. The uric acid sensor
was combined with a flow injection analysis system to structure
a bioanalytical system for monitoring the uric acid content in
the haemodialysis waste. The effect of interferents in the
sample had been reduced by modifying the electrode surface with
an electropolymerized 1,3-diaminobenzene / resorcinol film. The
resulted system could measure uric acid with a linear range
from 0.01 to 0.4 mg/dl and sensitivity 97.4nA/mg/dl. The
detection limit was 0.01 mg/dl. The correlation coefficient
with the clinical photometric method was 0.97.
|
author2 |
Jan,Gwo-Jen;Hsu,Tien-Tsai |
author_facet |
Jan,Gwo-Jen;Hsu,Tien-Tsai Hu,Yi-Wen 胡以文 |
author |
Hu,Yi-Wen 胡以文 |
spellingShingle |
Hu,Yi-Wen 胡以文 Development of a uric acid biosensing system for haemodialysis waste monitoring |
author_sort |
Hu,Yi-Wen |
title |
Development of a uric acid biosensing system for haemodialysis waste monitoring |
title_short |
Development of a uric acid biosensing system for haemodialysis waste monitoring |
title_full |
Development of a uric acid biosensing system for haemodialysis waste monitoring |
title_fullStr |
Development of a uric acid biosensing system for haemodialysis waste monitoring |
title_full_unstemmed |
Development of a uric acid biosensing system for haemodialysis waste monitoring |
title_sort |
development of a uric acid biosensing system for haemodialysis waste monitoring |
publishDate |
1996 |
url |
http://ndltd.ncl.edu.tw/handle/50750350268640075657 |
work_keys_str_mv |
AT huyiwen developmentofauricacidbiosensingsystemforhaemodialysiswastemonitoring AT húyǐwén developmentofauricacidbiosensingsystemforhaemodialysiswastemonitoring AT huyiwen niàosuānshēngwùgǎncèfēnxīxìtǒngzhīyánfājíqízàixuèyètòuxīfèiyèjiāncèshàngzhīyīngyòng AT húyǐwén niàosuānshēngwùgǎncèfēnxīxìtǒngzhīyánfājíqízàixuèyètòuxīfèiyèjiāncèshàngzhīyīngyòng |
_version_ |
1718346227483934720 |