Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings

碩士 === 國立臺灣師範大學 === 化學研究所 === 87 === Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings Abstract The C60/polycinnamaldehyde ( C60/PCA ) and C60/polyphenylacetylene ( C60/PPA ) copolymers were synthesized by using the Friedel — Craft reac...

Full description

Bibliographic Details
Main Authors: Rouahlin You, 游若琳
Other Authors: Jeng-Shong Shih
Format: Others
Language:zh-TW
Published: 1999
Online Access:http://ndltd.ncl.edu.tw/handle/82247324222151177999
id ndltd-TW-087NTNU0065008
record_format oai_dc
spelling ndltd-TW-087NTNU00650082015-10-13T11:46:56Z http://ndltd.ncl.edu.tw/handle/82247324222151177999 Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings 碳六十/聚合物石英壓電晶體偵測器之研製與應用 Rouahlin You 游若琳 碩士 國立臺灣師範大學 化學研究所 87 Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings Abstract The C60/polycinnamaldehyde ( C60/PCA ) and C60/polyphenylacetylene ( C60/PPA ) copolymers were synthesized by using the Friedel — Craft reaction and applized as the piezoelectric quartz crystal coating materials. A C60/polycinnamaldehyde (PCA) coated piezoelectric quartz crystal membrane sensor with a home — made computer interface was prepared and applied as a PZ protein sensor. The adsorption of protein such as hemoglobin onto the C60/PCA coated crystal resulted in the decrease of oscillating frequency. The variations of crystal frequency were converted to voltage with a frequency to voltage converter, and followed by amplification with OPA and data acquisition with analog to digital converter. It was found that hemoglobin had the best signal shift among the testing proteins. The PZ protein sensor exhibited good sensitivity of 6530 Hz / ( mg / mL ) and with detection limit of ppm level for hemoglobin. Furthermore, a C60/polyphenylacetylene (PPA) coated piezoelectric quartz crystal sensor with an Intell-8255 data processing system for various olefin vapors was also made. The aromatic hydrocarbons such as toluene seems to have greater adsorption onto C60/PPA membrane than alkynes, alkenes and alkanes. The absorption of ploycyclic aromatic hydrocarbons (PAHs) onto the C60/PPA membrane was also investigated. And we found that by using toluene as the solvent for PAHs, the C60/PPA membrane has a much larger frequency shift for naphthalene. Jeng-Shong Shih 施正雄 1999 學位論文 ; thesis 150 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣師範大學 === 化學研究所 === 87 === Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings Abstract The C60/polycinnamaldehyde ( C60/PCA ) and C60/polyphenylacetylene ( C60/PPA ) copolymers were synthesized by using the Friedel — Craft reaction and applized as the piezoelectric quartz crystal coating materials. A C60/polycinnamaldehyde (PCA) coated piezoelectric quartz crystal membrane sensor with a home — made computer interface was prepared and applied as a PZ protein sensor. The adsorption of protein such as hemoglobin onto the C60/PCA coated crystal resulted in the decrease of oscillating frequency. The variations of crystal frequency were converted to voltage with a frequency to voltage converter, and followed by amplification with OPA and data acquisition with analog to digital converter. It was found that hemoglobin had the best signal shift among the testing proteins. The PZ protein sensor exhibited good sensitivity of 6530 Hz / ( mg / mL ) and with detection limit of ppm level for hemoglobin. Furthermore, a C60/polyphenylacetylene (PPA) coated piezoelectric quartz crystal sensor with an Intell-8255 data processing system for various olefin vapors was also made. The aromatic hydrocarbons such as toluene seems to have greater adsorption onto C60/PPA membrane than alkynes, alkenes and alkanes. The absorption of ploycyclic aromatic hydrocarbons (PAHs) onto the C60/PPA membrane was also investigated. And we found that by using toluene as the solvent for PAHs, the C60/PPA membrane has a much larger frequency shift for naphthalene.
author2 Jeng-Shong Shih
author_facet Jeng-Shong Shih
Rouahlin You
游若琳
author Rouahlin You
游若琳
spellingShingle Rouahlin You
游若琳
Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings
author_sort Rouahlin You
title Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings
title_short Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings
title_full Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings
title_fullStr Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings
title_full_unstemmed Preparation and Application of Piezoelectric Crystal Detector Based on C60/Polymer Coatings
title_sort preparation and application of piezoelectric crystal detector based on c60/polymer coatings
publishDate 1999
url http://ndltd.ncl.edu.tw/handle/82247324222151177999
work_keys_str_mv AT rouahlinyou preparationandapplicationofpiezoelectriccrystaldetectorbasedonc60polymercoatings
AT yóuruòlín preparationandapplicationofpiezoelectriccrystaldetectorbasedonc60polymercoatings
AT rouahlinyou tànliùshíjùhéwùshíyīngyādiànjīngtǐzhēncèqìzhīyánzhìyǔyīngyòng
AT yóuruòlín tànliùshíjùhéwùshíyīngyādiànjīngtǐzhēncèqìzhīyánzhìyǔyīngyòng
_version_ 1716848306828607488