Experimental Responses of Steel Reduced Beam Section to Weak Panel Zone Moment Connections
碩士 === 國立臺灣大學 === 土木工程學研究所 === 87 === Five welded beam-to-column moment connections consist of reduced beam sections are cyclically tested. Key parameters include the amount of radius cut and the strength of the beam-column panel zone. Test results indicate that the average strain hardening ratio...