Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling
碩士 === 國立臺灣科技大學 === 營建工程系 === 87 === This experiment study discusses the fire behavior of motorcycles in the building arcade with different-material ceiling. Series full-scale tests, which include location of motorcycles and materials of ceiling in the building arcade, are conducted. Temperature pro...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1999
|
Online Access: | http://ndltd.ncl.edu.tw/handle/88115382443104284152 |
id |
ndltd-TW-087NTUST512065 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-087NTUST5120652016-02-01T04:12:44Z http://ndltd.ncl.edu.tw/handle/88115382443104284152 Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling 不同天花裝修下之騎樓機車火災行為研究 Chang-Han Chen 陳昶翰 碩士 國立臺灣科技大學 營建工程系 87 This experiment study discusses the fire behavior of motorcycles in the building arcade with different-material ceiling. Series full-scale tests, which include location of motorcycles and materials of ceiling in the building arcade, are conducted. Temperature profiles, heatflux and fire height are also measureed to analyze fire behavior and ceiling damage in the building arcade. It is found that the most serious damage is in the ceiling with wood materials and the next is aluminum, concrete and gypsum. The maximum flame height of the motorcycles fire in all tests exceed 5m and the exposure fire will spread to 2nd floor. The extent of heat flux may be more than 3m because radiation exceed the critical limit of ignition, excluding in the ceiling with gypsum. In conclusion, it is safer to use burn-enduring materials above all tests. Ching-Yung Lin 林慶元 1999 學位論文 ; thesis 0 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 營建工程系 === 87 === This experiment study discusses the fire behavior of motorcycles in the building arcade with different-material ceiling. Series full-scale tests, which include location of motorcycles and materials of ceiling in the building arcade, are conducted. Temperature profiles, heatflux and fire height are also measureed to analyze fire behavior and ceiling damage in the building arcade.
It is found that the most serious damage is in the ceiling with wood materials and the next is aluminum, concrete and gypsum. The maximum flame height of the motorcycles fire in all tests exceed 5m and the exposure fire will spread to 2nd floor. The extent of heat flux may be more than 3m because radiation exceed the critical limit of ignition, excluding in the ceiling with gypsum.
In conclusion, it is safer to use burn-enduring materials above all tests.
|
author2 |
Ching-Yung Lin |
author_facet |
Ching-Yung Lin Chang-Han Chen 陳昶翰 |
author |
Chang-Han Chen 陳昶翰 |
spellingShingle |
Chang-Han Chen 陳昶翰 Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling |
author_sort |
Chang-Han Chen |
title |
Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling |
title_short |
Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling |
title_full |
Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling |
title_fullStr |
Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling |
title_full_unstemmed |
Fire Behavior of Motorcycles in The Building Arcade With Different-material Ceiling |
title_sort |
fire behavior of motorcycles in the building arcade with different-material ceiling |
publishDate |
1999 |
url |
http://ndltd.ncl.edu.tw/handle/88115382443104284152 |
work_keys_str_mv |
AT changhanchen firebehaviorofmotorcyclesinthebuildingarcadewithdifferentmaterialceiling AT chénchǎnghàn firebehaviorofmotorcyclesinthebuildingarcadewithdifferentmaterialceiling AT changhanchen bùtóngtiānhuāzhuāngxiūxiàzhīqílóujīchēhuǒzāixíngwèiyánjiū AT chénchǎnghàn bùtóngtiānhuāzhuāngxiūxiàzhīqílóujīchēhuǒzāixíngwèiyánjiū |
_version_ |
1718175136894418944 |