The Study of High Tc Superconducting Planar First order gradiometer
碩士 === 國立臺灣師範大學 === 物理研究所 === 88 === In this thesis we fabricated and discussed the performance of high Tc superconducting planar directly coupled first order Gradiometer. The devices were patterned with the standardphotolithography, operated at temperatures up to 77 K. We found the equal...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2000
|
Online Access: | http://ndltd.ncl.edu.tw/handle/85471585381888972645 |
id |
ndltd-TW-088NTNU0198012 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-088NTNU01980122016-07-08T04:23:18Z http://ndltd.ncl.edu.tw/handle/85471585381888972645 The Study of High Tc Superconducting Planar First order gradiometer 高溫超導平面式一階梯度計物理特性之研究 Yu-Chien Liu 劉育杰 碩士 國立臺灣師範大學 物理研究所 88 In this thesis we fabricated and discussed the performance of high Tc superconducting planar directly coupled first order Gradiometer. The devices were patterned with the standardphotolithography, operated at temperatures up to 77 K. We found the equality of step-edge junctions was determined by the exposure time and the incident angle of Ar+ ion. The step-edge junction consisted with RSJ model. There are two main sources of magnetic flux noise spectrum. One is white noise independent of frequency,the other is 1/f noise proportional to reciprocal of frequency. We checked that the output voltage of gradiometer has linear relation with first order differential of magnetic field. However, the output voltage of gradiometer also depended on the angle between the magnetic gradient direction and baseline. It was found the maximum output voltage of gradiometer could be obtained while the two directions were parallel. Hong-Er Horng 洪姮娥 2000 學位論文 ; thesis 47 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣師範大學 === 物理研究所 === 88 === In this thesis we fabricated and discussed the performance of high Tc superconducting planar directly coupled first order Gradiometer.
The devices were patterned with the standardphotolithography, operated at temperatures up to 77 K. We found the equality of step-edge junctions was determined by the exposure time and the incident angle of Ar+ ion. The step-edge junction consisted with RSJ model.
There are two main sources of magnetic flux noise spectrum. One is white noise independent of frequency,the other is 1/f noise proportional to reciprocal of frequency.
We checked that the output voltage of gradiometer has linear relation with first order differential of magnetic field.
However, the output voltage of gradiometer also depended on the angle between the magnetic gradient direction and baseline. It was found the maximum output voltage of gradiometer could be obtained while the two directions were parallel.
|
author2 |
Hong-Er Horng |
author_facet |
Hong-Er Horng Yu-Chien Liu 劉育杰 |
author |
Yu-Chien Liu 劉育杰 |
spellingShingle |
Yu-Chien Liu 劉育杰 The Study of High Tc Superconducting Planar First order gradiometer |
author_sort |
Yu-Chien Liu |
title |
The Study of High Tc Superconducting Planar First order gradiometer |
title_short |
The Study of High Tc Superconducting Planar First order gradiometer |
title_full |
The Study of High Tc Superconducting Planar First order gradiometer |
title_fullStr |
The Study of High Tc Superconducting Planar First order gradiometer |
title_full_unstemmed |
The Study of High Tc Superconducting Planar First order gradiometer |
title_sort |
study of high tc superconducting planar first order gradiometer |
publishDate |
2000 |
url |
http://ndltd.ncl.edu.tw/handle/85471585381888972645 |
work_keys_str_mv |
AT yuchienliu thestudyofhightcsuperconductingplanarfirstordergradiometer AT liúyùjié thestudyofhightcsuperconductingplanarfirstordergradiometer AT yuchienliu gāowēnchāodǎopíngmiànshìyījiētīdùjìwùlǐtèxìngzhīyánjiū AT liúyùjié gāowēnchāodǎopíngmiànshìyījiētīdùjìwùlǐtèxìngzhīyánjiū AT yuchienliu studyofhightcsuperconductingplanarfirstordergradiometer AT liúyùjié studyofhightcsuperconductingplanarfirstordergradiometer |
_version_ |
1718341793137819648 |