Single Jet Impingement Cooling in a Roughened Rotating Square Duct
碩士 === 國立中山大學 === 機械工程學系研究所 === 89 === Abstract The experiments was studied on a rotating ribbed square duct from two different impingement position of air jets (termed as Type A and B) and at rotational speeds of 0,300 and 600 rpm。The jet impinged on two different geometric types of rib (square an...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2001
|
Online Access: | http://ndltd.ncl.edu.tw/handle/55286205840541704277 |
Summary: | 碩士 === 國立中山大學 === 機械工程學系研究所 === 89 === Abstract
The experiments was studied on a rotating ribbed square duct from two different impingement position of air jets (termed as Type A and B) and at rotational speeds of 0,300 and 600 rpm。The jet impinged on two different geometric types of rib (square and semi-circular ribs). The study covered jet Reynolds number 5000 to 9000 and the jet rotation number was varied from 0 to 0.0053. Results are presented and focused on the effect of two of circular jet arrangements and different geometric of ribs. Significant heat transfer enhancement was found for Type A configuration and square ribs within the ranges of operating parameters considered in the study. However, rotation induced Coriolis and centrifuged forces decreased the Nusselt number values (up to 20%) which is quitely conincided with those of previous studies.
|
---|