Measuerment and Analysis of Voltage Flicker

碩士 === 國立臺灣科技大學 === 電機工程系 === 89 === Abstract This thesis analyzes background values of voltage flicker by field measurement and statistics analysis in related substation. Synchronous measurement of voltage flicker in steel plants is used to probe into voltage fluctuation and voltage flic...

Full description

Bibliographic Details
Main Authors: Yau-Ting Wang, 王耀霆
Other Authors: Chi-Jui Wu
Format: Others
Language:zh-TW
Published: 2001
Online Access:http://ndltd.ncl.edu.tw/handle/73289506857519314673
id ndltd-TW-089NTUST442023
record_format oai_dc
spelling ndltd-TW-089NTUST4420232015-10-13T12:09:58Z http://ndltd.ncl.edu.tw/handle/73289506857519314673 Measuerment and Analysis of Voltage Flicker 電壓閃爍量測分析 Yau-Ting Wang 王耀霆 碩士 國立臺灣科技大學 電機工程系 89 Abstract This thesis analyzes background values of voltage flicker by field measurement and statistics analysis in related substation. Synchronous measurement of voltage flicker in steel plants is used to probe into voltage fluctuation and voltage flicker which DC and AC furnace loads cause. Arc furnace causes voltage flicker whose severity is decided by operating characteristics of arc furnaces, improvement equipment, and conditions of transmission networks. At fist, this thesis analyzes voltage flicker of related substation, MOFs of thirteen large-sizes steel plants, and arc furnace loads by methods of field measurement. Choosing the three most representative steel plants(161kV DC furnace, 69kV AC furnace, and 161kV AC furnace) to discuss their effects by experimental data and statistics outcomes on the transmission/distribution system. Experimental data contain voltage fluctuation, voltage flicker, and related power data. Using experimental data of arc furnaces to analyze three different tariff methods for reactive power. In addition, we also suggest a new tariff method, and hope it will help the industry. An appropriate and reasonable tariff method is able to let plant positively improve voltage flicker caused by reactive power load. Otherwise, this thesis also analyzes improvement effect of reactive power compensators of two 69kV AC furnaces according to calculation and measurement data. Finally, we apply spectral analysis to voltage fluctuation and voltage flicker for different operating characteristic and operating period of arc furnaces to explain the relation between ΔV and ΔV10 Chi-Jui Wu 吳啟瑞 2001 學位論文 ; thesis 146 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 89 === Abstract This thesis analyzes background values of voltage flicker by field measurement and statistics analysis in related substation. Synchronous measurement of voltage flicker in steel plants is used to probe into voltage fluctuation and voltage flicker which DC and AC furnace loads cause. Arc furnace causes voltage flicker whose severity is decided by operating characteristics of arc furnaces, improvement equipment, and conditions of transmission networks. At fist, this thesis analyzes voltage flicker of related substation, MOFs of thirteen large-sizes steel plants, and arc furnace loads by methods of field measurement. Choosing the three most representative steel plants(161kV DC furnace, 69kV AC furnace, and 161kV AC furnace) to discuss their effects by experimental data and statistics outcomes on the transmission/distribution system. Experimental data contain voltage fluctuation, voltage flicker, and related power data. Using experimental data of arc furnaces to analyze three different tariff methods for reactive power. In addition, we also suggest a new tariff method, and hope it will help the industry. An appropriate and reasonable tariff method is able to let plant positively improve voltage flicker caused by reactive power load. Otherwise, this thesis also analyzes improvement effect of reactive power compensators of two 69kV AC furnaces according to calculation and measurement data. Finally, we apply spectral analysis to voltage fluctuation and voltage flicker for different operating characteristic and operating period of arc furnaces to explain the relation between ΔV and ΔV10
author2 Chi-Jui Wu
author_facet Chi-Jui Wu
Yau-Ting Wang
王耀霆
author Yau-Ting Wang
王耀霆
spellingShingle Yau-Ting Wang
王耀霆
Measuerment and Analysis of Voltage Flicker
author_sort Yau-Ting Wang
title Measuerment and Analysis of Voltage Flicker
title_short Measuerment and Analysis of Voltage Flicker
title_full Measuerment and Analysis of Voltage Flicker
title_fullStr Measuerment and Analysis of Voltage Flicker
title_full_unstemmed Measuerment and Analysis of Voltage Flicker
title_sort measuerment and analysis of voltage flicker
publishDate 2001
url http://ndltd.ncl.edu.tw/handle/73289506857519314673
work_keys_str_mv AT yautingwang measuermentandanalysisofvoltageflicker
AT wángyàotíng measuermentandanalysisofvoltageflicker
AT yautingwang diànyāshǎnshuòliàngcèfēnxī
AT wángyàotíng diànyāshǎnshuòliàngcèfēnxī
_version_ 1716853671515389952