Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs

博士 === 國立成功大學 === 醫學工程研究所 === 90 === Amputations not only caused the loss of limb but also accompanied with inconvenience of physical mobility for the patients. The newly developed prosthetic designs make possible the replacement of amputated limbs, thus greatly improve the body mobility and life in...

Full description

Bibliographic Details
Main Authors: Gwo-Feng Huang, 黃國峰
Other Authors: You-Li Chou
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/6yf9qj
id ndltd-TW-090NCKU0530003
record_format oai_dc
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 博士 === 國立成功大學 === 醫學工程研究所 === 90 === Amputations not only caused the loss of limb but also accompanied with inconvenience of physical mobility for the patients. The newly developed prosthetic designs make possible the replacement of amputated limbs, thus greatly improve the body mobility and life independence of the patients. However, the real manifestation of the prosthetic gait and the discrepancy between the prosthetic and normal gaits needs further investigations, especially the effects of walking speeds and on walking surfaces. In Taiwan, the sockets of most prosthetic devices are made of resin. The ventilation of this type of socket is poor. In the summer time, the air temperature in Taiwan can rise to 34℃ or higher and humidity levels are 60 % or higher. The kind of weather is called muggy or steamy. Heavy sweating is a typical condition in such a climate. For amputees, heavy sweating is a major problem since the socket becomes wet and fills with sweat. Consequently, prosthetic socket devices have a tendency to come loose or fall off during locomotion. Moreover, the constant moisture can cause skin complications such as eczema, blisters, dermatitis, ulcers or infection in the residual limb. Some amputees may have to be hospitalized because of these complications. Some patients even require further amputation. However, to date, there are very few studies in this subject. In last decades many researchers have tried to improve socket material. Although these new prosthesis materials can improve the feeling of comfort, they cannot solve the sweating problem. Therefore it is very important to develop a socket system to facilitate ventilation, cooling and the elimination of sweat. In our study a new prosthesis design equipped with an electric automatic air ventilation system have been tested and the sweat due to high temperature and humidity inside the socket can be reduced. The total AVS, including fan and battery, weighted only about 95g. New prosthetic materials and designs have broadened the range of availability in artificial feet. As a result, it is becoming more difficult for prosthetists and clinical physicians to select the best foot for individual amputees. Much of the research evaluating the dynamics of prosthetic feet is subjective. Quantitative research on below-knee amputee gait has been performed in the following areas : dynamic evaluation of the foot through motion analysis, evaluation of forces created by and acting on the body while wearing a prosthetic foot, and amputees’ energy consumption with various foot designs The purposes of this thesis are to scientifically measure the dynamic gait characteristics of the amputee by using motion analysis and to measure the energy consumption for the below-knee amputee when wearing the SACH, single-axis and multiple-axis prosthetic feet on ground, slopes and stairs. First, the walking condition for patient with below-knee amputees is analyzed. Twenty patients who severed the shank are selected and divided into two groups to wear three different types of prosthetic foot : SACH foot (traditional type), single-axis foot, and multiple-axis foot, These patients on ground, slopes (5, 10 and 16 degrees) and stairs. These research results provide an objective for clinical physicians to select the proper type of prosthetic feet for the individual patient. Second, the energy consumption of three different types of prosthetic foot is conducted for the same twenty subjects. These subjects walk at speeds of 1 mile per hour, 1.5 mile per hour and 2 mile per hour on slope of 0, 3 and 6 degrees. Energy consumption is detected while walking by metabolic measurement cart and heavy-duty treadmill. Subjective results are additionally determined via questionnaire after testing. A survey is conducted to determine the comfort level of prosthetic foot with patients after the experiment. The records provide a objective and subjective records for physician’s prescription for amputees.
author2 You-Li Chou
author_facet You-Li Chou
Gwo-Feng Huang
黃國峰
author Gwo-Feng Huang
黃國峰
spellingShingle Gwo-Feng Huang
黃國峰
Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs
author_sort Gwo-Feng Huang
title Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs
title_short Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs
title_full Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs
title_fullStr Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs
title_full_unstemmed Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs
title_sort gait analysis and energy consumption of below-knee amputees with a new prosthesis on level ground, ramps and stairs
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/6yf9qj
work_keys_str_mv AT gwofenghuang gaitanalysisandenergyconsumptionofbelowkneeamputeeswithanewprosthesisonlevelgroundrampsandstairs
AT huángguófēng gaitanalysisandenergyconsumptionofbelowkneeamputeeswithanewprosthesisonlevelgroundrampsandstairs
AT gwofenghuang xīxiàjiézhīhuànzhěchuāndàixīnxíngyìzhīzàipíngdexiépōhéjiētīzhībùtàihénéngliàngxiāohàofēnxī
AT huángguófēng xīxiàjiézhīhuànzhěchuāndàixīnxíngyìzhīzàipíngdexiépōhéjiētīzhībùtàihénéngliàngxiāohàofēnxī
_version_ 1719086363113947136
spelling ndltd-TW-090NCKU05300032019-05-15T19:17:30Z http://ndltd.ncl.edu.tw/handle/6yf9qj Gait Analysis and Energy Consumption of Below-Knee Amputees With A New Prosthesis on Level Ground, Ramps and Stairs 膝下截肢患者穿戴新型義肢在平地、斜坡和階梯之步態和能量消耗分析 Gwo-Feng Huang 黃國峰 博士 國立成功大學 醫學工程研究所 90 Amputations not only caused the loss of limb but also accompanied with inconvenience of physical mobility for the patients. The newly developed prosthetic designs make possible the replacement of amputated limbs, thus greatly improve the body mobility and life independence of the patients. However, the real manifestation of the prosthetic gait and the discrepancy between the prosthetic and normal gaits needs further investigations, especially the effects of walking speeds and on walking surfaces. In Taiwan, the sockets of most prosthetic devices are made of resin. The ventilation of this type of socket is poor. In the summer time, the air temperature in Taiwan can rise to 34℃ or higher and humidity levels are 60 % or higher. The kind of weather is called muggy or steamy. Heavy sweating is a typical condition in such a climate. For amputees, heavy sweating is a major problem since the socket becomes wet and fills with sweat. Consequently, prosthetic socket devices have a tendency to come loose or fall off during locomotion. Moreover, the constant moisture can cause skin complications such as eczema, blisters, dermatitis, ulcers or infection in the residual limb. Some amputees may have to be hospitalized because of these complications. Some patients even require further amputation. However, to date, there are very few studies in this subject. In last decades many researchers have tried to improve socket material. Although these new prosthesis materials can improve the feeling of comfort, they cannot solve the sweating problem. Therefore it is very important to develop a socket system to facilitate ventilation, cooling and the elimination of sweat. In our study a new prosthesis design equipped with an electric automatic air ventilation system have been tested and the sweat due to high temperature and humidity inside the socket can be reduced. The total AVS, including fan and battery, weighted only about 95g. New prosthetic materials and designs have broadened the range of availability in artificial feet. As a result, it is becoming more difficult for prosthetists and clinical physicians to select the best foot for individual amputees. Much of the research evaluating the dynamics of prosthetic feet is subjective. Quantitative research on below-knee amputee gait has been performed in the following areas : dynamic evaluation of the foot through motion analysis, evaluation of forces created by and acting on the body while wearing a prosthetic foot, and amputees’ energy consumption with various foot designs The purposes of this thesis are to scientifically measure the dynamic gait characteristics of the amputee by using motion analysis and to measure the energy consumption for the below-knee amputee when wearing the SACH, single-axis and multiple-axis prosthetic feet on ground, slopes and stairs. First, the walking condition for patient with below-knee amputees is analyzed. Twenty patients who severed the shank are selected and divided into two groups to wear three different types of prosthetic foot : SACH foot (traditional type), single-axis foot, and multiple-axis foot, These patients on ground, slopes (5, 10 and 16 degrees) and stairs. These research results provide an objective for clinical physicians to select the proper type of prosthetic feet for the individual patient. Second, the energy consumption of three different types of prosthetic foot is conducted for the same twenty subjects. These subjects walk at speeds of 1 mile per hour, 1.5 mile per hour and 2 mile per hour on slope of 0, 3 and 6 degrees. Energy consumption is detected while walking by metabolic measurement cart and heavy-duty treadmill. Subjective results are additionally determined via questionnaire after testing. A survey is conducted to determine the comfort level of prosthetic foot with patients after the experiment. The records provide a objective and subjective records for physician’s prescription for amputees. You-Li Chou Fong-Chin Su 周有禮 蘇芳慶 2002 學位論文 ; thesis 156 zh-TW