Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces

碩士 === 國立中央大學 === 環境工程研究所 === 91 === Many studies indicate that both municipal waste incinerators (MWIs) and the industrial activities containing combustion processes are important sources of PCDD/F emissions. Local studies indicate that dioxin in ambient air originates mainly from electric arc f...

Full description

Bibliographic Details
Main Authors: Shian-Sheng Tsai, 蔡憲昇
Other Authors: Moo-Been Chang
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/93325308857238729568
id ndltd-TW-091NCU05515019
record_format oai_dc
spelling ndltd-TW-091NCU055150192016-06-22T04:14:52Z http://ndltd.ncl.edu.tw/handle/93325308857238729568 Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces 電弧爐煉鋼廠煙道戴奧辛排放特性之初步探討 Shian-Sheng Tsai 蔡憲昇 碩士 國立中央大學 環境工程研究所 91 Many studies indicate that both municipal waste incinerators (MWIs) and the industrial activities containing combustion processes are important sources of PCDD/F emissions. Local studies indicate that dioxin in ambient air originates mainly from electric arc furnaces. Electric arc furnaces (EAFs) have been identified as the major sources of PCDD/F emissions in Taiwan. Two kinds of EAFs including the direct evacuation system and the building evacuation system are selected for measuring the dioxin emission. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 22.50 ng/Nm3, and the total Toxic Equivalent Quantity (TEQ) concentration was 1.72 ng I-TEQ/Nm3. The PCDD/F concentration of stack gas in EAF-B was 2.19 ng/Nm3, and the TEQ concentration was 0.14 ng I-TEQ/Nm3. This result showed that the direct evacuation system emitted more dioxin than the building evacuation system. The other results obtained on gas/particulate partitioning of PCDD/Fs in EAFs indicate that more than 90% in the particulate-phase before the flue gas passed through APCD. The emission factor of EAF-A is 11.62 ng-I-TEQ/kg-product, while 7.36 ng-I-TEQ/kg-product is found for EAF-B. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF were the major contributors of the dioxin concentrations in each phase and the percentage of PCDD/F in particulate phase increases with the chlorination level of the PCDD/F congeners. The distributions of total Toxic Equivalent Quantity (TEQ) concentrations on 2,3,4,7,8-PeCDF at each sampling site were about 50%. Moo-Been Chang 張木彬 2003 學位論文 ; thesis 101 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 環境工程研究所 === 91 === Many studies indicate that both municipal waste incinerators (MWIs) and the industrial activities containing combustion processes are important sources of PCDD/F emissions. Local studies indicate that dioxin in ambient air originates mainly from electric arc furnaces. Electric arc furnaces (EAFs) have been identified as the major sources of PCDD/F emissions in Taiwan. Two kinds of EAFs including the direct evacuation system and the building evacuation system are selected for measuring the dioxin emission. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 22.50 ng/Nm3, and the total Toxic Equivalent Quantity (TEQ) concentration was 1.72 ng I-TEQ/Nm3. The PCDD/F concentration of stack gas in EAF-B was 2.19 ng/Nm3, and the TEQ concentration was 0.14 ng I-TEQ/Nm3. This result showed that the direct evacuation system emitted more dioxin than the building evacuation system. The other results obtained on gas/particulate partitioning of PCDD/Fs in EAFs indicate that more than 90% in the particulate-phase before the flue gas passed through APCD. The emission factor of EAF-A is 11.62 ng-I-TEQ/kg-product, while 7.36 ng-I-TEQ/kg-product is found for EAF-B. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF were the major contributors of the dioxin concentrations in each phase and the percentage of PCDD/F in particulate phase increases with the chlorination level of the PCDD/F congeners. The distributions of total Toxic Equivalent Quantity (TEQ) concentrations on 2,3,4,7,8-PeCDF at each sampling site were about 50%.
author2 Moo-Been Chang
author_facet Moo-Been Chang
Shian-Sheng Tsai
蔡憲昇
author Shian-Sheng Tsai
蔡憲昇
spellingShingle Shian-Sheng Tsai
蔡憲昇
Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces
author_sort Shian-Sheng Tsai
title Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces
title_short Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces
title_full Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces
title_fullStr Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces
title_full_unstemmed Evaluation of the Emission Characteristics of PCDD/Fs from Electric Arc Furnaces
title_sort evaluation of the emission characteristics of pcdd/fs from electric arc furnaces
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/93325308857238729568
work_keys_str_mv AT shianshengtsai evaluationoftheemissioncharacteristicsofpcddfsfromelectricarcfurnaces
AT càixiànshēng evaluationoftheemissioncharacteristicsofpcddfsfromelectricarcfurnaces
AT shianshengtsai diànhúlúliàngāngchǎngyāndàodàiàoxīnpáifàngtèxìngzhīchūbùtàntǎo
AT càixiànshēng diànhúlúliàngāngchǎngyāndàodàiàoxīnpáifàngtèxìngzhīchūbùtàntǎo
_version_ 1718316273837801472