腹動脈歧管壓力與流量量測及模式之建立

碩士 === 中華大學 === 機械與航太工程研究所 === 92 === Abstract The main function of circulation is to provide oxygen needed by physical tissues; nutrition and waste are metabolized that balance physical system as well. The circulation system contains heart and blood vessels. It is profound that heart is...

Full description

Bibliographic Details
Main Author: 陳永桐
Other Authors: 牛仰堯
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/25279953883768788547
id ndltd-TW-092CHPI0598010
record_format oai_dc
spelling ndltd-TW-092CHPI05980102016-01-04T04:08:39Z http://ndltd.ncl.edu.tw/handle/25279953883768788547 腹動脈歧管壓力與流量量測及模式之建立 陳永桐 碩士 中華大學 機械與航太工程研究所 92 Abstract The main function of circulation is to provide oxygen needed by physical tissues; nutrition and waste are metabolized that balance physical system as well. The circulation system contains heart and blood vessels. It is profound that heart is able to pump blood to each organ of body everywhere via vessels. However, heart and vessels disease are main dead cause of citizen recently, human rush to realize the key of circulation and find out source of disease. Flow delivering control and pressure measurement are main methods of circulation inspection. According to the result of many reports between high blood pressure team and normal blood pressure team, many studies point out that high blood pressure causing disease of artery hardening is more dramatically than normal blood pressure is. Therefore it is necessary to control blood pressure not too high which may prevent artery hardening. There is normal blood pressure under fixed flow delivering in blood vessels; Different pressure will be measured under different flow delivering in vessels. It is outstanding to discuss the flow changing of aortic and abdomen artery under blood pressure changing in bio-medical area. The main purpose of this study is to simulate and measure pressure after flow delivering to aorta and carotid. This study is to design a simple 3-dimension physical model for aortic pressure, blood flow and pressure distribution status after heart contraction and blood flow delivering to aorta and abdomen artery. This research utilize self-design model of the Arch of Aorta combining a sensor, as well as a water pump to substitute the heart pumping task. By simulation of various input pressure of aorta, flow pressure and distribution of output abdomen artery and aorta are measured. The result examination data is collected and read by PC to accomplish analysis and exploration. The result of this research may help to predict occurrence of aortic disease and make contribution in medical area. Keyword: blood pressure, blood flow, pressure, flow, aortic, abdomen artery, distribution vessels 牛仰堯 2004 學位論文 ; thesis 67 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中華大學 === 機械與航太工程研究所 === 92 === Abstract The main function of circulation is to provide oxygen needed by physical tissues; nutrition and waste are metabolized that balance physical system as well. The circulation system contains heart and blood vessels. It is profound that heart is able to pump blood to each organ of body everywhere via vessels. However, heart and vessels disease are main dead cause of citizen recently, human rush to realize the key of circulation and find out source of disease. Flow delivering control and pressure measurement are main methods of circulation inspection. According to the result of many reports between high blood pressure team and normal blood pressure team, many studies point out that high blood pressure causing disease of artery hardening is more dramatically than normal blood pressure is. Therefore it is necessary to control blood pressure not too high which may prevent artery hardening. There is normal blood pressure under fixed flow delivering in blood vessels; Different pressure will be measured under different flow delivering in vessels. It is outstanding to discuss the flow changing of aortic and abdomen artery under blood pressure changing in bio-medical area. The main purpose of this study is to simulate and measure pressure after flow delivering to aorta and carotid. This study is to design a simple 3-dimension physical model for aortic pressure, blood flow and pressure distribution status after heart contraction and blood flow delivering to aorta and abdomen artery. This research utilize self-design model of the Arch of Aorta combining a sensor, as well as a water pump to substitute the heart pumping task. By simulation of various input pressure of aorta, flow pressure and distribution of output abdomen artery and aorta are measured. The result examination data is collected and read by PC to accomplish analysis and exploration. The result of this research may help to predict occurrence of aortic disease and make contribution in medical area. Keyword: blood pressure, blood flow, pressure, flow, aortic, abdomen artery, distribution vessels
author2 牛仰堯
author_facet 牛仰堯
陳永桐
author 陳永桐
spellingShingle 陳永桐
腹動脈歧管壓力與流量量測及模式之建立
author_sort 陳永桐
title 腹動脈歧管壓力與流量量測及模式之建立
title_short 腹動脈歧管壓力與流量量測及模式之建立
title_full 腹動脈歧管壓力與流量量測及模式之建立
title_fullStr 腹動脈歧管壓力與流量量測及模式之建立
title_full_unstemmed 腹動脈歧管壓力與流量量測及模式之建立
title_sort 腹動脈歧管壓力與流量量測及模式之建立
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/25279953883768788547
work_keys_str_mv AT chényǒngtóng fùdòngmàiqíguǎnyālìyǔliúliàngliàngcèjímóshìzhījiànlì
_version_ 1718158897113464832