Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems

碩士 === 華梵大學 === 建築學系碩士班 === 92 === In many houses and offices air condition would be used for supplying cool and fresh air. However, the indoor air quality (IAQ) contains in uncertainty of the microorganism pollution and the disease infection. This research aims at (A) the measurement of...

Full description

Bibliographic Details
Main Authors: Shou-Cheng Liao, 廖守正
Other Authors: Chi-Hong Huang
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/35144048328956575082
id ndltd-TW-092HCHT0222001
record_format oai_dc
spelling ndltd-TW-092HCHT02220012015-10-13T15:29:40Z http://ndltd.ncl.edu.tw/handle/35144048328956575082 Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems 建築空調管道內微生物檢測及殺菌效果評估 Shou-Cheng Liao 廖守正 碩士 華梵大學 建築學系碩士班 92 In many houses and offices air condition would be used for supplying cool and fresh air. However, the indoor air quality (IAQ) contains in uncertainty of the microorganism pollution and the disease infection. This research aims at (A) the measurement of the microbiological distribution in HVAC Duct Systems for various rooms and (B) the improvement of microbiological with efficiency in HVAC Duct Systems. Several offices of different types are to be chosen in Taipei, using equipment to determinate microbiological and investigate the environmental details. Then it is to disinfect with the ultraviolet ray. This procedure would be carried on in a period of weeks. Finally, the suggestion to the building regulations would be proposed. The results demonstrate, 1. that the air condition piping systems content propagate for the microorganism easily, and the situations different from its environment, 2. that the ultraviolet ray disinfects effectively, lighting for about half an hour with efficiency of microbiological reduction over 90% and 3. that the possibility of propagating again after disinfecting, therefore a periodical maintaining would be necessary. Chi-Hong Huang Bai-Shing Hsiao 黃志弘 蕭百興 2004 學位論文 ; thesis 108 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 華梵大學 === 建築學系碩士班 === 92 === In many houses and offices air condition would be used for supplying cool and fresh air. However, the indoor air quality (IAQ) contains in uncertainty of the microorganism pollution and the disease infection. This research aims at (A) the measurement of the microbiological distribution in HVAC Duct Systems for various rooms and (B) the improvement of microbiological with efficiency in HVAC Duct Systems. Several offices of different types are to be chosen in Taipei, using equipment to determinate microbiological and investigate the environmental details. Then it is to disinfect with the ultraviolet ray. This procedure would be carried on in a period of weeks. Finally, the suggestion to the building regulations would be proposed. The results demonstrate, 1. that the air condition piping systems content propagate for the microorganism easily, and the situations different from its environment, 2. that the ultraviolet ray disinfects effectively, lighting for about half an hour with efficiency of microbiological reduction over 90% and 3. that the possibility of propagating again after disinfecting, therefore a periodical maintaining would be necessary.
author2 Chi-Hong Huang
author_facet Chi-Hong Huang
Shou-Cheng Liao
廖守正
author Shou-Cheng Liao
廖守正
spellingShingle Shou-Cheng Liao
廖守正
Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems
author_sort Shou-Cheng Liao
title Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems
title_short Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems
title_full Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems
title_fullStr Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems
title_full_unstemmed Evaluation of Steriziling Efficiency And Microbiological Determination in HVAC Duct Systems
title_sort evaluation of steriziling efficiency and microbiological determination in hvac duct systems
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/35144048328956575082
work_keys_str_mv AT shouchengliao evaluationofsterizilingefficiencyandmicrobiologicaldeterminationinhvacductsystems
AT liàoshǒuzhèng evaluationofsterizilingefficiencyandmicrobiologicaldeterminationinhvacductsystems
AT shouchengliao jiànzhúkōngdiàoguǎndàonèiwēishēngwùjiǎncèjíshājūnxiàoguǒpínggū
AT liàoshǒuzhèng jiànzhúkōngdiàoguǎndàonèiwēishēngwùjiǎncèjíshājūnxiàoguǒpínggū
_version_ 1717765908024262656