Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension
碩士 === 國立陽明大學 === 復健科技輔具研究所 === 92 === Objectives: The purpose of this study was to compare lower extremity joint kinematics and kinetics during level walking with and without a functional knee brace in stroke patients with knee hyperextension. Design: VICON370 Motion analysis systems were collect...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2004
|
Online Access: | http://ndltd.ncl.edu.tw/handle/12948910253209379564 |
id |
ndltd-TW-092YM005353009 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-092YM0053530092015-10-13T13:08:16Z http://ndltd.ncl.edu.tw/handle/12948910253209379564 Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension 功能性膝支架對膝反弓之中風患者步態的效應研究 Ming-I Chen 陳明義 碩士 國立陽明大學 復健科技輔具研究所 92 Objectives: The purpose of this study was to compare lower extremity joint kinematics and kinetics during level walking with and without a functional knee brace in stroke patients with knee hyperextension. Design: VICON370 Motion analysis systems were collected kinematics data and synchronize collected kinetics data with AMTI 3-dimentational force platform system, 12 hemipelgia subjects were including our study. Setting: A gait laboratory. Main Outcome Measures: Step width, step length, cycle time and ROM over lower limb kinematics variables and max hip, knee, and ankle joint moment kinetics variables during level walking. Results: Step width, sound side stride length, affective side stride length, sound side hip flexion-extension, hip abduction-adduction, knee flexion-extension and affective side hip flexion-extension, knee flexion-extension, and ankle plantarflexion-dorsiflexion were significant difference (p, < 0.05). The kinetics variables were significant difference over affective lower extremity including Max hip extensor moment, hip external rotator moment, knee abductor moment, knee extensor moment, knee external rotator moment, knee flexor moment, ankle eversion moment, ankle plantarflexor moment and ankle dorsiflexor moment (p, < 0.05).. Conclusion: Stoke patients with knee hyperextension applying functional knee brace may lead the more step width, step length and less ROM over sound and affective lower extremity and required less hip flexor, knee flexor, knee extensor, ankle dorsiflexor, but required more ankle plantarflexor moment. Chung-huang Yu 游忠煌 2004 學位論文 ; thesis 92 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立陽明大學 === 復健科技輔具研究所 === 92 === Objectives: The purpose of this study was to compare lower extremity joint kinematics and kinetics during level walking with and without a functional knee brace in stroke patients with knee hyperextension.
Design: VICON370 Motion analysis systems were collected kinematics data and synchronize collected kinetics data with AMTI 3-dimentational force platform system, 12 hemipelgia subjects were including our study.
Setting: A gait laboratory.
Main Outcome Measures: Step width, step length, cycle time and ROM over lower limb kinematics variables and max hip, knee, and ankle joint moment kinetics variables during level walking.
Results: Step width, sound side stride length, affective side stride length, sound side hip flexion-extension, hip abduction-adduction, knee flexion-extension and affective side hip flexion-extension, knee flexion-extension, and ankle plantarflexion-dorsiflexion were significant difference (p, < 0.05). The kinetics variables were significant difference over affective lower extremity including Max hip extensor moment, hip external rotator moment, knee abductor moment, knee extensor moment, knee external rotator moment, knee flexor moment, ankle eversion moment, ankle plantarflexor moment and ankle dorsiflexor moment (p, < 0.05)..
Conclusion: Stoke patients with knee hyperextension applying functional knee brace may lead the more step width, step length and less ROM over sound and affective lower extremity and required less hip flexor, knee flexor, knee extensor, ankle dorsiflexor, but required more ankle plantarflexor moment.
|
author2 |
Chung-huang Yu |
author_facet |
Chung-huang Yu Ming-I Chen 陳明義 |
author |
Ming-I Chen 陳明義 |
spellingShingle |
Ming-I Chen 陳明義 Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension |
author_sort |
Ming-I Chen |
title |
Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension |
title_short |
Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension |
title_full |
Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension |
title_fullStr |
Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension |
title_full_unstemmed |
Effects of Functional Knee Brace on gait pattern in Stroke Patient with Knee Hyperextension |
title_sort |
effects of functional knee brace on gait pattern in stroke patient with knee hyperextension |
publishDate |
2004 |
url |
http://ndltd.ncl.edu.tw/handle/12948910253209379564 |
work_keys_str_mv |
AT mingichen effectsoffunctionalkneebraceongaitpatterninstrokepatientwithkneehyperextension AT chénmíngyì effectsoffunctionalkneebraceongaitpatterninstrokepatientwithkneehyperextension AT mingichen gōngnéngxìngxīzhījiàduìxīfǎngōngzhīzhōngfēnghuànzhěbùtàidexiàoyīngyánjiū AT chénmíngyì gōngnéngxìngxīzhījiàduìxīfǎngōngzhīzhōngfēnghuànzhěbùtàidexiàoyīngyánjiū |
_version_ |
1717732305591599104 |