碩士 === 國立成功大學 === 工程科學系碩博士班 === 93 ===  This paper presents a microfluidic chip capable of automatically performing precise and continuous pH measurements. It is an electrochemical sensing system integrated with a microfluid and environmental monitoring system based on MEMS-technology. The chip’s mi...

Full description

Bibliographic Details
Main Authors: Chen-Fu Lin, 林建甫
Other Authors: Huei-Huang Lee
Format: Others
Language:zh-TW
Published: 2005
Online Access:http://ndltd.ncl.edu.tw/handle/54561286523651770214
id ndltd-TW-093NCKU5028069
record_format oai_dc
spelling ndltd-TW-093NCKU50280692017-06-07T04:36:43Z http://ndltd.ncl.edu.tw/handle/54561286523651770214 Multi-functional Electrochemical Detecting System Using Microfluidic Technology 微流體多功能電化學檢測系統 Chen-Fu Lin 林建甫 碩士 國立成功大學 工程科學系碩博士班 93  This paper presents a microfluidic chip capable of automatically performing precise and continuous pH measurements. It is an electrochemical sensing system integrated with a microfluid and environmental monitoring system based on MEMS-technology. The chip’s microfluidic control devices and microchannels are made of PDMS (Polydimethylsiloxane), and its reference electrodes fabricated with AgCl. One of the two sensing electrodes is fabricated by sputtering a layer of SLBTLO (SiO2-LiO2-BaO-TiO2-La2O3) for evaluating pH value. The ion selective membrane on the second electrode is made from ETH 129( N, N, N’, N’-tetracyclohexyl-3-oxa-pentane-diaminde)which allows for the sensing of calcium ion concentration. Temperature sensors feed back information around the sensing electrodes to immediately calibrate the electrochemical sensors. A flow sensor monitors the flow rate of the micropumps to measure the volume of sample transported. The performance of the developed sensing chip is close to that of traditional sensing systems. The sensitivity of pH value and calcium ion concentration is -57.74mV/pH and 34.7mV/decade. The chip can simultaneously detect hydrogen and calcium ion concentration within 200 seconds and the sample size needed is 100μL. Additionally, a pneumatic fluid-control device facilitates the automatic sample injection and a continuous sensing operation. The developed system can provide a convenient and portable tool in a wide range of biomedical applications. Huei-Huang Lee 李輝煌 2005 學位論文 ; thesis 97 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 工程科學系碩博士班 === 93 ===  This paper presents a microfluidic chip capable of automatically performing precise and continuous pH measurements. It is an electrochemical sensing system integrated with a microfluid and environmental monitoring system based on MEMS-technology. The chip’s microfluidic control devices and microchannels are made of PDMS (Polydimethylsiloxane), and its reference electrodes fabricated with AgCl. One of the two sensing electrodes is fabricated by sputtering a layer of SLBTLO (SiO2-LiO2-BaO-TiO2-La2O3) for evaluating pH value. The ion selective membrane on the second electrode is made from ETH 129( N, N, N’, N’-tetracyclohexyl-3-oxa-pentane-diaminde)which allows for the sensing of calcium ion concentration. Temperature sensors feed back information around the sensing electrodes to immediately calibrate the electrochemical sensors. A flow sensor monitors the flow rate of the micropumps to measure the volume of sample transported. The performance of the developed sensing chip is close to that of traditional sensing systems. The sensitivity of pH value and calcium ion concentration is -57.74mV/pH and 34.7mV/decade. The chip can simultaneously detect hydrogen and calcium ion concentration within 200 seconds and the sample size needed is 100μL. Additionally, a pneumatic fluid-control device facilitates the automatic sample injection and a continuous sensing operation. The developed system can provide a convenient and portable tool in a wide range of biomedical applications.
author2 Huei-Huang Lee
author_facet Huei-Huang Lee
Chen-Fu Lin
林建甫
author Chen-Fu Lin
林建甫
spellingShingle Chen-Fu Lin
林建甫
Multi-functional Electrochemical Detecting System Using Microfluidic Technology
author_sort Chen-Fu Lin
title Multi-functional Electrochemical Detecting System Using Microfluidic Technology
title_short Multi-functional Electrochemical Detecting System Using Microfluidic Technology
title_full Multi-functional Electrochemical Detecting System Using Microfluidic Technology
title_fullStr Multi-functional Electrochemical Detecting System Using Microfluidic Technology
title_full_unstemmed Multi-functional Electrochemical Detecting System Using Microfluidic Technology
title_sort multi-functional electrochemical detecting system using microfluidic technology
publishDate 2005
url http://ndltd.ncl.edu.tw/handle/54561286523651770214
work_keys_str_mv AT chenfulin multifunctionalelectrochemicaldetectingsystemusingmicrofluidictechnology
AT línjiànfǔ multifunctionalelectrochemicaldetectingsystemusingmicrofluidictechnology
AT chenfulin wēiliútǐduōgōngnéngdiànhuàxuéjiǎncèxìtǒng
AT línjiànfǔ wēiliútǐduōgōngnéngdiànhuàxuéjiǎncèxìtǒng
_version_ 1718456158056873984