Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller

碩士 === 國立中山大學 === 電機工程學系研究所 === 93 === For the operation of refuse incineration plant, the major difficulties with trash are the unstable nature and the uncertainty. The complexity of trash ingredient causes the traditional control method fail to obtain a stable combustion condition and steam flow r...

Full description

Bibliographic Details
Main Authors: Cheng-Yu Tsai, 蔡正裕
Other Authors: Whei-Min Lin
Format: Others
Language:zh-TW
Published: 2005
Online Access:http://ndltd.ncl.edu.tw/handle/42875466317164008695
id ndltd-TW-093NSYS5442107
record_format oai_dc
spelling ndltd-TW-093NSYS54421072015-12-23T04:08:15Z http://ndltd.ncl.edu.tw/handle/42875466317164008695 Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller DATYPEFUZZYPID之焚化爐燃燒控制 Cheng-Yu Tsai 蔡正裕 碩士 國立中山大學 電機工程學系研究所 93 For the operation of refuse incineration plant, the major difficulties with trash are the unstable nature and the uncertainty. The complexity of trash ingredient causes the traditional control method fail to obtain a stable combustion condition and steam flow rate. It is necessary to seek a new control method to adapt to the volatile combustion features of refuse incinerator. Based on correlation literature research [2], the fuzzy control theory is proposed to provide a good combustion condition to stabilize the steam flow rate for the combustion control of refuse furnace, and effectively reduce the rate of personnel involvement. Different from the rule based fuzzy theory, the Direct Action type Fuzzy Proportion-Integral-Differential control theory (Direct Action type Fuzzy PID) is designed to combine a single input variable and three-rule fuzzy inference system. With a traditional PID controller, the DA type Fuzzy PID controller will have a simple structure as well as the nonlinear output property. Object of control is a reverse-acting grate type incinerator. Establishment of the model is done with estimates of the value of LHV and steam flow rate, coordinating the actual structure of furnace to infer the speed variable feeder model. Establishment and simulation of the control system works under the MATLAB environment. Parameter-tuning of the controller uses the Genetic Algorithm (GA) for optimization. By joining the furnace model and the controller for simulation, it proves that the Direct Action type Fuzzy PID controller has good performance and is feasible to the combustion control for refuse incineration plant. Whei-Min Lin 林惠民 2005 學位論文 ; thesis 91 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中山大學 === 電機工程學系研究所 === 93 === For the operation of refuse incineration plant, the major difficulties with trash are the unstable nature and the uncertainty. The complexity of trash ingredient causes the traditional control method fail to obtain a stable combustion condition and steam flow rate. It is necessary to seek a new control method to adapt to the volatile combustion features of refuse incinerator. Based on correlation literature research [2], the fuzzy control theory is proposed to provide a good combustion condition to stabilize the steam flow rate for the combustion control of refuse furnace, and effectively reduce the rate of personnel involvement. Different from the rule based fuzzy theory, the Direct Action type Fuzzy Proportion-Integral-Differential control theory (Direct Action type Fuzzy PID) is designed to combine a single input variable and three-rule fuzzy inference system. With a traditional PID controller, the DA type Fuzzy PID controller will have a simple structure as well as the nonlinear output property. Object of control is a reverse-acting grate type incinerator. Establishment of the model is done with estimates of the value of LHV and steam flow rate, coordinating the actual structure of furnace to infer the speed variable feeder model. Establishment and simulation of the control system works under the MATLAB environment. Parameter-tuning of the controller uses the Genetic Algorithm (GA) for optimization. By joining the furnace model and the controller for simulation, it proves that the Direct Action type Fuzzy PID controller has good performance and is feasible to the combustion control for refuse incineration plant.
author2 Whei-Min Lin
author_facet Whei-Min Lin
Cheng-Yu Tsai
蔡正裕
author Cheng-Yu Tsai
蔡正裕
spellingShingle Cheng-Yu Tsai
蔡正裕
Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller
author_sort Cheng-Yu Tsai
title Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller
title_short Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller
title_full Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller
title_fullStr Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller
title_full_unstemmed Combustion Control of Refuse Incineration Plant by DA Type Fuzzy PID Controller
title_sort combustion control of refuse incineration plant by da type fuzzy pid controller
publishDate 2005
url http://ndltd.ncl.edu.tw/handle/42875466317164008695
work_keys_str_mv AT chengyutsai combustioncontrolofrefuseincinerationplantbydatypefuzzypidcontroller
AT càizhèngyù combustioncontrolofrefuseincinerationplantbydatypefuzzypidcontroller
AT chengyutsai datypefuzzypidzhīfénhuàlúránshāokòngzhì
AT càizhèngyù datypefuzzypidzhīfénhuàlúránshāokòngzhì
_version_ 1718156629338226688