Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters

碩士 === 國立中正大學 === 電機工程所 === 94 === Arc furnaces used for steel production are a main cause of voltage fluctuations in electrical networks, which may give rise to the flicker effect. Voltage fluctuations, due to ramdom are-length variations during scrap melting. Static-var-compensator(SVC) are instal...

Full description

Bibliographic Details
Main Authors: Ja-shung Liao, 廖家祥
Other Authors: none
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/87806002395680063188
id ndltd-TW-094CCU05442029
record_format oai_dc
spelling ndltd-TW-094CCU054420292015-10-13T10:45:18Z http://ndltd.ncl.edu.tw/handle/87806002395680063188 Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters 主動式與被動式濾波器在含交流電弧爐負載之諧波改善與分析 Ja-shung Liao 廖家祥 碩士 國立中正大學 電機工程所 94 Arc furnaces used for steel production are a main cause of voltage fluctuations in electrical networks, which may give rise to the flicker effect. Voltage fluctuations, due to ramdom are-length variations during scrap melting. Static-var-compensator(SVC) are installed in plants feeding arc furnaces in order to compensate both voltage fluctuation and voltage distortion. This thesis discuss simulation and analyze harmonic characteristicd generated by a steel firm, that equipped with arc furnace, high-power ac/dc adjustable speed drives cycloconverters and static var compensator(SVC) and passive harmonic filters. From actual measurements and analyzed and compared with the simulation results obtained by using MATLAB/Simulink and EMTP/ATP. It is shown that simulation results and the actual measurement are in a good agreement. Then install active power filter(APF)and high order passive harmonic at steel firm by simulation. To observe harmonic improvement situation. The contributions of thesis include (1)Typical steel firm including several harmonic and flicker sources, to simulation and measure harmonic components using software, (2)To compare active power filter and passive harmonic filters harmonic improvement situation when install at steel firm, (3)To compare cost when install active power filter and passive harmonic filters, (4)Building an ac electric arc furnace modle using EMTP which is suitable for time-domain harmonic analysis. none 張文恭 2006 學位論文 ; thesis 91 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中正大學 === 電機工程所 === 94 === Arc furnaces used for steel production are a main cause of voltage fluctuations in electrical networks, which may give rise to the flicker effect. Voltage fluctuations, due to ramdom are-length variations during scrap melting. Static-var-compensator(SVC) are installed in plants feeding arc furnaces in order to compensate both voltage fluctuation and voltage distortion. This thesis discuss simulation and analyze harmonic characteristicd generated by a steel firm, that equipped with arc furnace, high-power ac/dc adjustable speed drives cycloconverters and static var compensator(SVC) and passive harmonic filters. From actual measurements and analyzed and compared with the simulation results obtained by using MATLAB/Simulink and EMTP/ATP. It is shown that simulation results and the actual measurement are in a good agreement. Then install active power filter(APF)and high order passive harmonic at steel firm by simulation. To observe harmonic improvement situation. The contributions of thesis include (1)Typical steel firm including several harmonic and flicker sources, to simulation and measure harmonic components using software, (2)To compare active power filter and passive harmonic filters harmonic improvement situation when install at steel firm, (3)To compare cost when install active power filter and passive harmonic filters, (4)Building an ac electric arc furnace modle using EMTP which is suitable for time-domain harmonic analysis.
author2 none
author_facet none
Ja-shung Liao
廖家祥
author Ja-shung Liao
廖家祥
spellingShingle Ja-shung Liao
廖家祥
Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters
author_sort Ja-shung Liao
title Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters
title_short Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters
title_full Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters
title_fullStr Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters
title_full_unstemmed Harmonic Mitigation and Analysis of AC Arc Furnace Loads with Using Active and Passive Filters
title_sort harmonic mitigation and analysis of ac arc furnace loads with using active and passive filters
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/87806002395680063188
work_keys_str_mv AT jashungliao harmonicmitigationandanalysisofacarcfurnaceloadswithusingactiveandpassivefilters
AT liàojiāxiáng harmonicmitigationandanalysisofacarcfurnaceloadswithusingactiveandpassivefilters
AT jashungliao zhǔdòngshìyǔbèidòngshìlǜbōqìzàihánjiāoliúdiànhúlúfùzàizhīxiébōgǎishànyǔfēnxī
AT liàojiāxiáng zhǔdòngshìyǔbèidòngshìlǜbōqìzàihánjiāoliúdiànhúlúfùzàizhīxiébōgǎishànyǔfēnxī
_version_ 1716833103452831744