Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis

碩士 === 國立臺灣大學 === 土木工程學研究所 === 94 === In this thesis, we analyze and design the piezoelectric device by finite element simulation. The modeling and simulation have been applied in three subjects: admittance of piezoelectric device, directivity of distance sensor, and high intensity focused ultrasoun...

Full description

Bibliographic Details
Main Authors: Nien-Ti Tsou, 鄒年棣
Other Authors: Chuin-Shan Chen
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/20701154434568525234
id ndltd-TW-094NTU05015062
record_format oai_dc
spelling ndltd-TW-094NTU050150622015-12-16T04:38:21Z http://ndltd.ncl.edu.tw/handle/20701154434568525234 Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis 應用有限元素法模擬壓電元件與超音波波傳 Nien-Ti Tsou 鄒年棣 碩士 國立臺灣大學 土木工程學研究所 94 In this thesis, we analyze and design the piezoelectric device by finite element simulation. The modeling and simulation have been applied in three subjects: admittance of piezoelectric device, directivity of distance sensor, and high intensity focused ultrasound( HIFU). For admittance of piezoelectric device, a methodology to model mechanical losses of piezoelectric devices by the finite element analysis is presented. Complex parts of the material constants are extracted using an iterative method. Mechanical losses of piezoelectric devices are taken into account through these complex constants. A scheme using the QR factorization is developed to decompose mechanical losses of an arbitrary-shaped device into fundamental modes. These losses are then transformed into an equivalent viscous damping ratio in a standard finite element dynamics analysis. The proposed method enables us to obtain a reliable mechanical loss factor. Numerical results demonstrate that the proposed method can predict measured admittance spectra reasonably well. For directivity of distance sensor, we analyze the effect of different boundary conditions to the half decay angle. The goal for vehicle short-range sensing is that the half decay angle in the vertical direction has to be less than that in horizontal. Our simulation reveals that the half decay angle of free end boundary condition is much less than that of simple-supported and fixed ends. With such design criterion in mind, we further improve the distance sensor device by cutting a square hole in the vertical direction to mimic the free-end boundary condition. This procedure can improve the asymmetry of directivity up to 50%. However, it shortens the detect region. Therefore, we change the length of cave and obtain an optimized value, 0.4 times of device diameter, for the directivity and detect region. The HIFU application requires the length to width ratio of -3dB focal area to reach a maximum value. To this end, we construct the HIFU simulation model to find out the relations between the modal shape and resonance frequency, and compare the numerical result with experimental measurements. Furthermore, we change geometric focal length and angle in the same active area to explore the effect of -3dB focal area. The result reveals that small geometric focal length and large angle may decrease the -3dB focal area, and increase length to width ratio and the pressure magnitude of main lobe. In conclusion, we have successfully shown the feasibility of using finite element simulation to analyze the behavior of piezoelectric devices. Through the aforementioned simulation, we can predict the energy loss of piezoelectric material and provide a guideline for design of distance sensor and HIFU. Chuin-Shan Chen 陳俊杉 2006 學位論文 ; thesis 114 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 土木工程學研究所 === 94 === In this thesis, we analyze and design the piezoelectric device by finite element simulation. The modeling and simulation have been applied in three subjects: admittance of piezoelectric device, directivity of distance sensor, and high intensity focused ultrasound( HIFU). For admittance of piezoelectric device, a methodology to model mechanical losses of piezoelectric devices by the finite element analysis is presented. Complex parts of the material constants are extracted using an iterative method. Mechanical losses of piezoelectric devices are taken into account through these complex constants. A scheme using the QR factorization is developed to decompose mechanical losses of an arbitrary-shaped device into fundamental modes. These losses are then transformed into an equivalent viscous damping ratio in a standard finite element dynamics analysis. The proposed method enables us to obtain a reliable mechanical loss factor. Numerical results demonstrate that the proposed method can predict measured admittance spectra reasonably well. For directivity of distance sensor, we analyze the effect of different boundary conditions to the half decay angle. The goal for vehicle short-range sensing is that the half decay angle in the vertical direction has to be less than that in horizontal. Our simulation reveals that the half decay angle of free end boundary condition is much less than that of simple-supported and fixed ends. With such design criterion in mind, we further improve the distance sensor device by cutting a square hole in the vertical direction to mimic the free-end boundary condition. This procedure can improve the asymmetry of directivity up to 50%. However, it shortens the detect region. Therefore, we change the length of cave and obtain an optimized value, 0.4 times of device diameter, for the directivity and detect region. The HIFU application requires the length to width ratio of -3dB focal area to reach a maximum value. To this end, we construct the HIFU simulation model to find out the relations between the modal shape and resonance frequency, and compare the numerical result with experimental measurements. Furthermore, we change geometric focal length and angle in the same active area to explore the effect of -3dB focal area. The result reveals that small geometric focal length and large angle may decrease the -3dB focal area, and increase length to width ratio and the pressure magnitude of main lobe. In conclusion, we have successfully shown the feasibility of using finite element simulation to analyze the behavior of piezoelectric devices. Through the aforementioned simulation, we can predict the energy loss of piezoelectric material and provide a guideline for design of distance sensor and HIFU.
author2 Chuin-Shan Chen
author_facet Chuin-Shan Chen
Nien-Ti Tsou
鄒年棣
author Nien-Ti Tsou
鄒年棣
spellingShingle Nien-Ti Tsou
鄒年棣
Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis
author_sort Nien-Ti Tsou
title Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis
title_short Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis
title_full Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis
title_fullStr Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis
title_full_unstemmed Simulation of Piezoelectric Device and Ultrasonic Wave using Finite Element Analysis
title_sort simulation of piezoelectric device and ultrasonic wave using finite element analysis
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/20701154434568525234
work_keys_str_mv AT nientitsou simulationofpiezoelectricdeviceandultrasonicwaveusingfiniteelementanalysis
AT zōuniándì simulationofpiezoelectricdeviceandultrasonicwaveusingfiniteelementanalysis
AT nientitsou yīngyòngyǒuxiànyuánsùfǎmónǐyādiànyuánjiànyǔchāoyīnbōbōchuán
AT zōuniándì yīngyòngyǒuxiànyuánsùfǎmónǐyādiànyuánjiànyǔchāoyīnbōbōchuán
_version_ 1718149487428370432