A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller

碩士 === 國立臺北科技大學 === 冷凍空調工程系所 === 94 === Centrifugal chiller is the single largest electrical load in central air-conditioning system. Energy efficiency of a chiller is critical to energy saving performance for a building. This thesis presents that the COP of a variable frequency drive (VFD) centrifu...

Full description

Bibliographic Details
Main Authors: King-Huei Hsu, 徐金輝
Other Authors: 卓清松
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/g3fktr
id ndltd-TW-094TIT05703007
record_format oai_dc
spelling ndltd-TW-094TIT057030072019-06-01T03:41:55Z http://ndltd.ncl.edu.tw/handle/g3fktr A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller 變頻離心式冰水機節能效益之研究 King-Huei Hsu 徐金輝 碩士 國立臺北科技大學 冷凍空調工程系所 94 Centrifugal chiller is the single largest electrical load in central air-conditioning system. Energy efficiency of a chiller is critical to energy saving performance for a building. This thesis presents that the COP of a variable frequency drive (VFD) centrifugal chiller at operating conditions here in Taiwan is far better than a constant speed drive (CSD) chiller. An ARI certified computer program is used to simulate operation of two 350 tons centrifugal chillers, one is VFD and the other one is constant speed. Analyzed results show that COP of a VFD chiller operates between 100% and 40% load is up to 70% higher than that of the CSD chiller if ECWT drops to 20 ℃ from 30 ℃. COP can be further improved by resetting leaving chilled water temperature if relative humidity is not a concern. The conclusion of this thesis may provide some guidelines for those professionals when they make a selection of centrifugal chillers. Then VFD chillers may be more popularly applied in air-conditioning system design as an effective measure to achieve energy saving requirements. 卓清松 2006 學位論文 ; thesis 95 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 冷凍空調工程系所 === 94 === Centrifugal chiller is the single largest electrical load in central air-conditioning system. Energy efficiency of a chiller is critical to energy saving performance for a building. This thesis presents that the COP of a variable frequency drive (VFD) centrifugal chiller at operating conditions here in Taiwan is far better than a constant speed drive (CSD) chiller. An ARI certified computer program is used to simulate operation of two 350 tons centrifugal chillers, one is VFD and the other one is constant speed. Analyzed results show that COP of a VFD chiller operates between 100% and 40% load is up to 70% higher than that of the CSD chiller if ECWT drops to 20 ℃ from 30 ℃. COP can be further improved by resetting leaving chilled water temperature if relative humidity is not a concern. The conclusion of this thesis may provide some guidelines for those professionals when they make a selection of centrifugal chillers. Then VFD chillers may be more popularly applied in air-conditioning system design as an effective measure to achieve energy saving requirements.
author2 卓清松
author_facet 卓清松
King-Huei Hsu
徐金輝
author King-Huei Hsu
徐金輝
spellingShingle King-Huei Hsu
徐金輝
A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller
author_sort King-Huei Hsu
title A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller
title_short A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller
title_full A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller
title_fullStr A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller
title_full_unstemmed A Study on Energy Saving Performance of Variable Frequency Drive Centrifugal Chiller
title_sort study on energy saving performance of variable frequency drive centrifugal chiller
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/g3fktr
work_keys_str_mv AT kinghueihsu astudyonenergysavingperformanceofvariablefrequencydrivecentrifugalchiller
AT xújīnhuī astudyonenergysavingperformanceofvariablefrequencydrivecentrifugalchiller
AT kinghueihsu biànpínlíxīnshìbīngshuǐjījiénéngxiàoyìzhīyánjiū
AT xújīnhuī biànpínlíxīnshìbīngshuǐjījiénéngxiàoyìzhīyánjiū
AT kinghueihsu studyonenergysavingperformanceofvariablefrequencydrivecentrifugalchiller
AT xújīnhuī studyonenergysavingperformanceofvariablefrequencydrivecentrifugalchiller
_version_ 1719197332825702400