碩士 === 淡江大學 === 化學工程與材料工程學系碩士班 === 94 === In this study, the influences of operating parameters on flat-membrane submerged filtrations of BSA solution were investigated. The operating parameters included aeration rate, suction pressure, membrane characteristics and module inclination angle. The expe...

Full description

Bibliographic Details
Main Authors: Pei-fu Tsai, 蔡焙
Other Authors: Tung-Wen Cheng
Format: Others
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/37016192352048882474
id ndltd-TW-094TKU05063008
record_format oai_dc
spelling ndltd-TW-094TKU050630082016-05-30T04:21:19Z http://ndltd.ncl.edu.tw/handle/37016192352048882474 A Study on Protein Fouling of Submerged Membrane Filtration System 沉浸式薄膜過濾系統中蛋白質結垢之探討 Pei-fu Tsai 蔡焙 碩士 淡江大學 化學工程與材料工程學系碩士班 94 In this study, the influences of operating parameters on flat-membrane submerged filtrations of BSA solution were investigated. The operating parameters included aeration rate, suction pressure, membrane characteristics and module inclination angle. The experimental results were summarized as follows: (1) During the operation of single-liquid phase filtration of BSA solution, hydrophilic membrane has a higher flux than hydrophobic one; (2) The flux of 1600 membrane inclination is higher than that of 900 inclination at the same aeration rate; (3) The way of blocking of the membrane does not happen step by step from standard blocking, complete blocking, intermediate blocking to cake filtration, but occurs coincidently; (4) The change of feed concentrate does not influence the way of blocking; (5) Aeration can effectively reduce the filtration resistance of cake filtration according to the blocking mechanism analysis. Tung-Wen Cheng 鄭東文 學位論文 ; thesis 93 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 淡江大學 === 化學工程與材料工程學系碩士班 === 94 === In this study, the influences of operating parameters on flat-membrane submerged filtrations of BSA solution were investigated. The operating parameters included aeration rate, suction pressure, membrane characteristics and module inclination angle. The experimental results were summarized as follows: (1) During the operation of single-liquid phase filtration of BSA solution, hydrophilic membrane has a higher flux than hydrophobic one; (2) The flux of 1600 membrane inclination is higher than that of 900 inclination at the same aeration rate; (3) The way of blocking of the membrane does not happen step by step from standard blocking, complete blocking, intermediate blocking to cake filtration, but occurs coincidently; (4) The change of feed concentrate does not influence the way of blocking; (5) Aeration can effectively reduce the filtration resistance of cake filtration according to the blocking mechanism analysis.
author2 Tung-Wen Cheng
author_facet Tung-Wen Cheng
Pei-fu Tsai
蔡焙
author Pei-fu Tsai
蔡焙
spellingShingle Pei-fu Tsai
蔡焙
A Study on Protein Fouling of Submerged Membrane Filtration System
author_sort Pei-fu Tsai
title A Study on Protein Fouling of Submerged Membrane Filtration System
title_short A Study on Protein Fouling of Submerged Membrane Filtration System
title_full A Study on Protein Fouling of Submerged Membrane Filtration System
title_fullStr A Study on Protein Fouling of Submerged Membrane Filtration System
title_full_unstemmed A Study on Protein Fouling of Submerged Membrane Filtration System
title_sort study on protein fouling of submerged membrane filtration system
url http://ndltd.ncl.edu.tw/handle/37016192352048882474
work_keys_str_mv AT peifutsai astudyonproteinfoulingofsubmergedmembranefiltrationsystem
AT càibèi astudyonproteinfoulingofsubmergedmembranefiltrationsystem
AT peifutsai chénjìnshìbáomóguòlǜxìtǒngzhōngdànbáizhìjiégòuzhītàntǎo
AT càibèi chénjìnshìbáomóguòlǜxìtǒngzhōngdànbáizhìjiégòuzhītàntǎo
AT peifutsai studyonproteinfoulingofsubmergedmembranefiltrationsystem
AT càibèi studyonproteinfoulingofsubmergedmembranefiltrationsystem
_version_ 1718284273197252608