Simulating Dynamic Behavior of a Steam-Turbine Power Generation system at Incinerator Plant

碩士 === 國立高雄應用科技大學 === 電機工程系碩士班 === 95 === This thesis presents the dynamic behavior simulation of a steam-turbine power generation system at incinerator plant operating in normal and abnormal situations. The models of the system components included prime mover model, synchronous generator model, exc...

Full description

Bibliographic Details
Main Authors: Jung-Fan Chen, 陳榮芳
Other Authors: Meng-Jen Chen
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/95278645080686969627
Description
Summary:碩士 === 國立高雄應用科技大學 === 電機工程系碩士班 === 95 === This thesis presents the dynamic behavior simulation of a steam-turbine power generation system at incinerator plant operating in normal and abnormal situations. The models of the system components included prime mover model, synchronous generator model, excitation system model, three-phase power transformer model, induction motor model, and static load model. They were developed to cater for the dynamic behavior of the system using Simulink and SimPowerSystems. Varying calorific value of the waste was considered in the simulations, and the simulation results showed that the system operated acceptably under those conditions and should be coincident with practical operations. The dynamic behavior study for a steam-turbine power generation system at incinerator plant is essential for system planning, operation, and further expansion.