Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park

碩士 === 國立雲林科技大學 === 環境與安全工程系碩士班 === 95 === Micrometeorology has been widely used upon the measurement of agricultural meteorology and forest biological emission flux. In the past, researches using micrometeorlogy measurement on industry emission are seldom found. The purpose of this research is to t...

Full description

Bibliographic Details
Main Authors: Yi-hsiang Fang, 方義翔
Other Authors: none
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/94322377602746659544
id ndltd-TW-095YUNT5633060
record_format oai_dc
spelling ndltd-TW-095YUNT56330602016-05-20T04:18:00Z http://ndltd.ncl.edu.tw/handle/94322377602746659544 Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park 發展微氣象法量測石化工業區NMHC逸散源通量之研究 Yi-hsiang Fang 方義翔 碩士 國立雲林科技大學 環境與安全工程系碩士班 95 Micrometeorology has been widely used upon the measurement of agricultural meteorology and forest biological emission flux. In the past, researches using micrometeorlogy measurement on industry emission are seldom found. The purpose of this research is to try using Multi Pumps Relaxed Eddy Accumulation (MPREA) Method, one of many ways in Micrometeorlogy, in the petrochemical industry to carry out the flux measurement and discuss the empirical coefficient b value and flux result. A field study had been held to measure the fluxes of non-methane hydrocarbon (NMHC) components above a petrochemical industry park. The research had been conducted over a time period from November 2006 to July 2007. Data for the research had been collected from two locations: one from a flat lawn inside National YunLin University Science and Technology (NYUST), a test site measuring flux 12 meters above ground level; the other took place on a tower in a petrochemical corporation in YunLin County,Taiwan. The flux data had been collected at 78 meters above ground. From the site of NYUST, data collected indicated that the empirical coefficient bw value is between 0.58~0.63 and bT is between 0.46~0.57; the outcomes are within range of the theory value and suggestion value. In measurement flux test part, momentum flux of experiment and theory value range from 0.185 to 0.751 and 0.191 to 0.744 m2/s respectively. The sensible flux of experiment and theory value range from -0.088 to 0.195 and -0.103 to 0.220 ℃/m-s. (noted that vertical wind speed range from 0.009 to 0.298 m/s with an average value of -0.123 m/s which is an insignificant deviation of vertical wind speed.) The data collection of the NMHC concentration had been taken from 40 different locations in the petrochemical industry park. The average NMHC concentration in the petrochemical area is 1.2 to 2.4ppm with specially high concentration of NMHC reaching 6 to 7ppm near flair tower and storing tank area. The measure result of industry park site indicated, average value between 0.22 to 2.05 m/s of vertical wind speed, total average about 0.686 m/s. the momentum flux of experiment result range from 0.039 to 0.811 m2/s. The variation range is between 2% to 40% of the theory and experiment value. The sensible flux range from -6.04 to 0.293 ℃/m-s. In the NNMHC flux aspect, the NMHC flux of downward range from 10 to 4310 mg/m2-h, NMHC flux of upward range from 50 to 8440 mg/m2-h. none 謝祝欽 2007 學位論文 ; thesis 73 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立雲林科技大學 === 環境與安全工程系碩士班 === 95 === Micrometeorology has been widely used upon the measurement of agricultural meteorology and forest biological emission flux. In the past, researches using micrometeorlogy measurement on industry emission are seldom found. The purpose of this research is to try using Multi Pumps Relaxed Eddy Accumulation (MPREA) Method, one of many ways in Micrometeorlogy, in the petrochemical industry to carry out the flux measurement and discuss the empirical coefficient b value and flux result. A field study had been held to measure the fluxes of non-methane hydrocarbon (NMHC) components above a petrochemical industry park. The research had been conducted over a time period from November 2006 to July 2007. Data for the research had been collected from two locations: one from a flat lawn inside National YunLin University Science and Technology (NYUST), a test site measuring flux 12 meters above ground level; the other took place on a tower in a petrochemical corporation in YunLin County,Taiwan. The flux data had been collected at 78 meters above ground. From the site of NYUST, data collected indicated that the empirical coefficient bw value is between 0.58~0.63 and bT is between 0.46~0.57; the outcomes are within range of the theory value and suggestion value. In measurement flux test part, momentum flux of experiment and theory value range from 0.185 to 0.751 and 0.191 to 0.744 m2/s respectively. The sensible flux of experiment and theory value range from -0.088 to 0.195 and -0.103 to 0.220 ℃/m-s. (noted that vertical wind speed range from 0.009 to 0.298 m/s with an average value of -0.123 m/s which is an insignificant deviation of vertical wind speed.) The data collection of the NMHC concentration had been taken from 40 different locations in the petrochemical industry park. The average NMHC concentration in the petrochemical area is 1.2 to 2.4ppm with specially high concentration of NMHC reaching 6 to 7ppm near flair tower and storing tank area. The measure result of industry park site indicated, average value between 0.22 to 2.05 m/s of vertical wind speed, total average about 0.686 m/s. the momentum flux of experiment result range from 0.039 to 0.811 m2/s. The variation range is between 2% to 40% of the theory and experiment value. The sensible flux range from -6.04 to 0.293 ℃/m-s. In the NNMHC flux aspect, the NMHC flux of downward range from 10 to 4310 mg/m2-h, NMHC flux of upward range from 50 to 8440 mg/m2-h.
author2 none
author_facet none
Yi-hsiang Fang
方義翔
author Yi-hsiang Fang
方義翔
spellingShingle Yi-hsiang Fang
方義翔
Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park
author_sort Yi-hsiang Fang
title Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park
title_short Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park
title_full Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park
title_fullStr Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park
title_full_unstemmed Study of Micrometeorology for Measure of NMHC Emission Flux in Petrochemical Industry Park
title_sort study of micrometeorology for measure of nmhc emission flux in petrochemical industry park
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/94322377602746659544
work_keys_str_mv AT yihsiangfang studyofmicrometeorologyformeasureofnmhcemissionfluxinpetrochemicalindustrypark
AT fāngyìxiáng studyofmicrometeorologyformeasureofnmhcemissionfluxinpetrochemicalindustrypark
AT yihsiangfang fāzhǎnwēiqìxiàngfǎliàngcèshíhuàgōngyèqūnmhcyìsànyuántōngliàngzhīyánjiū
AT fāngyìxiáng fāzhǎnwēiqìxiàngfǎliàngcèshíhuàgōngyèqūnmhcyìsànyuántōngliàngzhīyánjiū
_version_ 1718273029745672192