Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal

碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 96 === Repetitive transcranial magnetic stimulation (rTMS) is a non-invasive technique to stimulate the brain, nerve and muscle by electric fields that are generated from an excitation coil. rTMS offers potential benefit as a therapeutic treatment for a variety of n...

Full description

Bibliographic Details
Main Authors: Yi-Cheng Chen, 陳怡誠
Other Authors: Jia-Jin Jason Chen
Format: Others
Language:en_US
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/60691433693916231099
id ndltd-TW-096NCKU5530015
record_format oai_dc
spelling ndltd-TW-096NCKU55300152016-05-09T04:14:20Z http://ndltd.ncl.edu.tw/handle/60691433693916231099 Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal 設計重複性顱磁刺激治療系統之線圈應用於動物實驗 Yi-Cheng Chen 陳怡誠 碩士 國立成功大學 醫學工程研究所碩博士班 96 Repetitive transcranial magnetic stimulation (rTMS) is a non-invasive technique to stimulate the brain, nerve and muscle by electric fields that are generated from an excitation coil. rTMS offers potential benefit as a therapeutic treatment for a variety of neurological and psychiatric disorders. Although various rTMS schemes have been developed for clinical studies, there is a lack of the coil for generating localized magnetic field with enhanced intensity for rTMS in small animal. The aim of this study was to design a miniature stimulation coil for rTMS studies in small animal. First, a circular coil with iron-core for improving the penetration of the magnetic field was designed which was equipped with a water cooling apparatus to prevent from over heat. In addition, the shields of varied sizes and shapes were employed to localize the stimulation area which distribution was measured in a magnetic field recording platform using Hall effect probe controlled by 2D step motor. Our results indicated that copper plate of 1 mm thickness with proper opening can shield well and provide localized stimulation to elicit motor evoked potential (MEP). However, the shock wave generated by magnetic stimulation was enhanced during the shielding experiment which might elicit auditory startle reflex (ASR) instead of MEP. Thus, a better sound proof design to reduce the sound below 96 dB should be taken into consideration when design a shielded rTMS for small animal. Jia-Jin Jason Chen 陳家進 2008 學位論文 ; thesis 35 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 96 === Repetitive transcranial magnetic stimulation (rTMS) is a non-invasive technique to stimulate the brain, nerve and muscle by electric fields that are generated from an excitation coil. rTMS offers potential benefit as a therapeutic treatment for a variety of neurological and psychiatric disorders. Although various rTMS schemes have been developed for clinical studies, there is a lack of the coil for generating localized magnetic field with enhanced intensity for rTMS in small animal. The aim of this study was to design a miniature stimulation coil for rTMS studies in small animal. First, a circular coil with iron-core for improving the penetration of the magnetic field was designed which was equipped with a water cooling apparatus to prevent from over heat. In addition, the shields of varied sizes and shapes were employed to localize the stimulation area which distribution was measured in a magnetic field recording platform using Hall effect probe controlled by 2D step motor. Our results indicated that copper plate of 1 mm thickness with proper opening can shield well and provide localized stimulation to elicit motor evoked potential (MEP). However, the shock wave generated by magnetic stimulation was enhanced during the shielding experiment which might elicit auditory startle reflex (ASR) instead of MEP. Thus, a better sound proof design to reduce the sound below 96 dB should be taken into consideration when design a shielded rTMS for small animal.
author2 Jia-Jin Jason Chen
author_facet Jia-Jin Jason Chen
Yi-Cheng Chen
陳怡誠
author Yi-Cheng Chen
陳怡誠
spellingShingle Yi-Cheng Chen
陳怡誠
Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal
author_sort Yi-Cheng Chen
title Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal
title_short Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal
title_full Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal
title_fullStr Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal
title_full_unstemmed Coil Design of Repetitive Transcranial Magnetic Stimulation System for Small Animal
title_sort coil design of repetitive transcranial magnetic stimulation system for small animal
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/60691433693916231099
work_keys_str_mv AT yichengchen coildesignofrepetitivetranscranialmagneticstimulationsystemforsmallanimal
AT chényíchéng coildesignofrepetitivetranscranialmagneticstimulationsystemforsmallanimal
AT yichengchen shèjìzhòngfùxìnglúcícìjīzhìliáoxìtǒngzhīxiànquānyīngyòngyúdòngwùshíyàn
AT chényíchéng shèjìzhòngfùxìnglúcícìjīzhìliáoxìtǒngzhīxiànquānyīngyòngyúdòngwùshíyàn
_version_ 1718264137051537408