Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses

碩士 === 國立嘉義大學 === 應用數學系研究所 === 96 === In this paper, we will introduce non-smooth analysis theory, to study the problem of the aortic valve and build the dynamics model for the carotid artery blood flow. In the course of the study, we use ultrasound to conduct clinical trials and research, building...

Full description

Bibliographic Details
Main Authors: Jia-Yu Chen, 陳家祐
Other Authors: Jia-Wen Chen
Format: Others
Language:en_US
Online Access:http://ndltd.ncl.edu.tw/handle/69048158975221089188
id ndltd-TW-096NCYU5507010
record_format oai_dc
spelling ndltd-TW-096NCYU55070102015-11-27T04:04:35Z http://ndltd.ncl.edu.tw/handle/69048158975221089188 Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses 以正切圓錐方法測量頸動脈脈動的重搏切跡 Jia-Yu Chen 陳家祐 碩士 國立嘉義大學 應用數學系研究所 96 In this paper, we will introduce non-smooth analysis theory, to study the problem of the aortic valve and build the dynamics model for the carotid artery blood flow. In the course of the study, we use ultrasound to conduct clinical trials and research, building a series of digital medical imaging. We researched and analysed these images to get a series of information and data, using tangent cone methods to measure the dicrotic notches in the carotid pulses, to develop a new method to differentiate aortic valve atresia insufficiency, the result can provide further medical treatment of cardiovascular disease in the application of the medical diagnostic value. Jia-Wen Chen 陳嘉文 學位論文 ; thesis 0 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立嘉義大學 === 應用數學系研究所 === 96 === In this paper, we will introduce non-smooth analysis theory, to study the problem of the aortic valve and build the dynamics model for the carotid artery blood flow. In the course of the study, we use ultrasound to conduct clinical trials and research, building a series of digital medical imaging. We researched and analysed these images to get a series of information and data, using tangent cone methods to measure the dicrotic notches in the carotid pulses, to develop a new method to differentiate aortic valve atresia insufficiency, the result can provide further medical treatment of cardiovascular disease in the application of the medical diagnostic value.
author2 Jia-Wen Chen
author_facet Jia-Wen Chen
Jia-Yu Chen
陳家祐
author Jia-Yu Chen
陳家祐
spellingShingle Jia-Yu Chen
陳家祐
Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses
author_sort Jia-Yu Chen
title Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses
title_short Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses
title_full Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses
title_fullStr Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses
title_full_unstemmed Tangent Cone Methods for the Measurement of the Dicrotic Notches in the Carotid Pulses
title_sort tangent cone methods for the measurement of the dicrotic notches in the carotid pulses
url http://ndltd.ncl.edu.tw/handle/69048158975221089188
work_keys_str_mv AT jiayuchen tangentconemethodsforthemeasurementofthedicroticnotchesinthecarotidpulses
AT chénjiāyòu tangentconemethodsforthemeasurementofthedicroticnotchesinthecarotidpulses
AT jiayuchen yǐzhèngqièyuánzhuīfāngfǎcèliàngjǐngdòngmàimàidòngdezhòngbóqièjī
AT chénjiāyòu yǐzhèngqièyuánzhuīfāngfǎcèliàngjǐngdòngmàimàidòngdezhòngbóqièjī
_version_ 1718138665025142784