Data analysis on MRI data using ICA :from single to group dataset

博士 === 國立清華大學 === 生醫工程與環境科學系 === 96 === Independent component analysis (ICA) decomposes mixing signal into their constituent components and is commonly used in the research of signal segmentation and functional localization in magnetic resonance imaging (MRI) field. Recently, analysis on MRI data s...

Full description

Bibliographic Details
Main Authors: Chia-Ju Chen, 陳佳如
Other Authors: Keh-Shih Chuang
Format: Others
Language:en_US
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/67643489686347187416
id ndltd-TW-096NTHU5810005
record_format oai_dc
spelling ndltd-TW-096NTHU58100052015-10-13T14:08:18Z http://ndltd.ncl.edu.tw/handle/67643489686347187416 Data analysis on MRI data using ICA :from single to group dataset 獨立成份方法分析磁振造影資料:個別到群組的數據分析 Chia-Ju Chen 陳佳如 博士 國立清華大學 生醫工程與環境科學系 96 Independent component analysis (ICA) decomposes mixing signal into their constituent components and is commonly used in the research of signal segmentation and functional localization in magnetic resonance imaging (MRI) field. Recently, analysis on MRI data show that the interesting source signals attributing to brain activity can be regarded as independent. In perfusion study, ICA utilizes the temporal-spatial independence to segment the tissue into gray, white matter and the tissue surrounding vessel which is affected by the local field inhomogeneity during the contrast agent passage. Besides the perfusion study, ICA is also applied to locate the brain activity region by the level of blood-oxygen dependence under task delivery in function study. Determination of the data dimension in data analysis could reduce the computer loading and increase the computation speed. However, the traditional estimation methods (i.e. Akaike information criterion (AIC), Bayesian information criterion (BIC) and minimum description length (MDL)) over-estimate the dimension number due to the variation of between- and within-subject. This over-estimated situation can be decreased by a conservative method: the fitting of auto-regression model with first order, acronymic in autoregressive model of order one (AR (1)). It estimates the dimension of data by fitting the noise part of data because it assumes that the noise contribution to data is colored. In this work, ICA combined and the extended AR(1) method is applied to a series of MRI data from single dataset, single-group dataset to multi-group dataset. In the first part, ICA is used to segment the tissue around vessel in perfusion MRI study. In the second part, extended ICA is applied to single group dataset for drug abuse investigation. The resultant performance is compared with the traditional model based method. In the third part, an extended AR(1) method is used to assess the data dimension in order to handle the analysis of a giant dataset with multi-groups. In the final part, an application to the brain default system is involved to study the brain function consistency across time series. Preliminary result showed that the ICA performed excellent signal decomposition on the data. The partial volume problem for the region around the vessel is alleviated by ICA and a better arterial input function (AIF) for quantifying physiological parameters can be achieved. Subsequently, ICA utilize a non-parametric model of drug effect as compared with the traditional parametric model and it also provides extra information for the drug study such as behavior task, physiology test during scan delivery. With the same concept, ICA also helps the analysis on the brain function under resting state. The results showed that the brain default function is consistent existing across time frame and it is also exposed that ICA combined with our home-made dimension estimation method could alleviate the overestimation of dimension caused by the variation of within- and between-subject. In conclusion, ICA is a powerful tool in analyzing data. The relative research such as brain connectivity under brain resting state and the extra information involved to ICA is worth investigation and development. Keh-Shih Chuang 莊克士 2008 學位論文 ; thesis 114 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 博士 === 國立清華大學 === 生醫工程與環境科學系 === 96 === Independent component analysis (ICA) decomposes mixing signal into their constituent components and is commonly used in the research of signal segmentation and functional localization in magnetic resonance imaging (MRI) field. Recently, analysis on MRI data show that the interesting source signals attributing to brain activity can be regarded as independent. In perfusion study, ICA utilizes the temporal-spatial independence to segment the tissue into gray, white matter and the tissue surrounding vessel which is affected by the local field inhomogeneity during the contrast agent passage. Besides the perfusion study, ICA is also applied to locate the brain activity region by the level of blood-oxygen dependence under task delivery in function study. Determination of the data dimension in data analysis could reduce the computer loading and increase the computation speed. However, the traditional estimation methods (i.e. Akaike information criterion (AIC), Bayesian information criterion (BIC) and minimum description length (MDL)) over-estimate the dimension number due to the variation of between- and within-subject. This over-estimated situation can be decreased by a conservative method: the fitting of auto-regression model with first order, acronymic in autoregressive model of order one (AR (1)). It estimates the dimension of data by fitting the noise part of data because it assumes that the noise contribution to data is colored. In this work, ICA combined and the extended AR(1) method is applied to a series of MRI data from single dataset, single-group dataset to multi-group dataset. In the first part, ICA is used to segment the tissue around vessel in perfusion MRI study. In the second part, extended ICA is applied to single group dataset for drug abuse investigation. The resultant performance is compared with the traditional model based method. In the third part, an extended AR(1) method is used to assess the data dimension in order to handle the analysis of a giant dataset with multi-groups. In the final part, an application to the brain default system is involved to study the brain function consistency across time series. Preliminary result showed that the ICA performed excellent signal decomposition on the data. The partial volume problem for the region around the vessel is alleviated by ICA and a better arterial input function (AIF) for quantifying physiological parameters can be achieved. Subsequently, ICA utilize a non-parametric model of drug effect as compared with the traditional parametric model and it also provides extra information for the drug study such as behavior task, physiology test during scan delivery. With the same concept, ICA also helps the analysis on the brain function under resting state. The results showed that the brain default function is consistent existing across time frame and it is also exposed that ICA combined with our home-made dimension estimation method could alleviate the overestimation of dimension caused by the variation of within- and between-subject. In conclusion, ICA is a powerful tool in analyzing data. The relative research such as brain connectivity under brain resting state and the extra information involved to ICA is worth investigation and development.
author2 Keh-Shih Chuang
author_facet Keh-Shih Chuang
Chia-Ju Chen
陳佳如
author Chia-Ju Chen
陳佳如
spellingShingle Chia-Ju Chen
陳佳如
Data analysis on MRI data using ICA :from single to group dataset
author_sort Chia-Ju Chen
title Data analysis on MRI data using ICA :from single to group dataset
title_short Data analysis on MRI data using ICA :from single to group dataset
title_full Data analysis on MRI data using ICA :from single to group dataset
title_fullStr Data analysis on MRI data using ICA :from single to group dataset
title_full_unstemmed Data analysis on MRI data using ICA :from single to group dataset
title_sort data analysis on mri data using ica :from single to group dataset
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/67643489686347187416
work_keys_str_mv AT chiajuchen dataanalysisonmridatausingicafromsingletogroupdataset
AT chénjiārú dataanalysisonmridatausingicafromsingletogroupdataset
AT chiajuchen dúlìchéngfènfāngfǎfēnxīcízhènzàoyǐngzīliàogèbiédàoqúnzǔdeshùjùfēnxī
AT chénjiārú dúlìchéngfènfāngfǎfēnxīcízhènzàoyǐngzīliàogèbiédàoqúnzǔdeshùjùfēnxī
_version_ 1717749345024999424