Development of the novel cuff-less blood pressure measurement device

碩士 === 中原大學 === 醫學工程研究所 === 97 === Hypertension, diabetes and stroke are the three major chronic diseases of the people in Taiwan. In the clinical applications, the benefit of invasive blood pressure measurement is that it can record the continuous pressure pulse accurately. However, it can’t be use...

Full description

Bibliographic Details
Main Authors: Yao-Lin Kao, 高耀臨
Other Authors: Liang-Yu Shyu
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/61779267871840670149
id ndltd-TW-097CYCU5530039
record_format oai_dc
spelling ndltd-TW-097CYCU55300392015-10-13T13:43:19Z http://ndltd.ncl.edu.tw/handle/61779267871840670149 Development of the novel cuff-less blood pressure measurement device 新型無氣囊血壓量測裝置之開發 Yao-Lin Kao 高耀臨 碩士 中原大學 醫學工程研究所 97 Hypertension, diabetes and stroke are the three major chronic diseases of the people in Taiwan. In the clinical applications, the benefit of invasive blood pressure measurement is that it can record the continuous pressure pulse accurately. However, it can’t be used in routine examination. Although the non-invasive blood pressure measurement can be used at home and in routine examination, it causes discomfort during measurement due to the high air pressure applied by the air pump. Besides, it can not be easily carried around because of its size. For these reasons, this study purposes to construct a novel blood pressure measurement device without the air cuff. The proposed device measures blood pressure through a mechanism that is made of silicon rubber. The system consists of a 8051F321 to control the measurement flow and perform necessary computation. Thus, the final result is a portable real-time non-invasive blood pressure measurement system. In this study, blood pressure readings were obtained using the new system and bedside monitor (Spacelabs Medical, model 90367) from ten young volunteers. The results of mean pressure, systolic pressure and diastolic pressure from the new system were all higher than those from bedside monitor. Including all measured blood pressure readings, the correlation coefficient between these two system for mean, systolic and diastolic pressures were 0.15, 0.18 and 0.29, respectively. Re-exam the collected data, we found that when the speed of pressure application is too fast or too slow or the obtained blood pressure waveform characteristic did not coincide with typical oscillometric measurement, large variations appear. However, after exclude the above mentioned measurements, there is no significant improvement, the correlation coefficients of mean, systolic and diastolic pressures were 0.16, 0.16 and 0.38, respectively. Further examination, we identified one more factor that can influence the measurement result that is, during the measurement, there must included more than eight blood pressure pulses that conformed with oscillometric blood pressure measurement characteristic. After eliminating these recorded, the correlation coefficient increased to 0.71, 0.60 and 0.41 for diastolic pressure, mean pressure and systolic pressure, respectively. We can conclude from these results that the accuracy can be improved effectively by defining the user regulation more precisely. The above mentioned interference factors can be identified and eliminated by the microprocessor to provide a reliable blood pressure measurement in practical applications. In this study, low accuracy is still troubling the current system. If the accuracy can be improved by incorporating the foregoing findings, this new system may replace the traditional devices in the future. Liang-Yu Shyu 徐良育 2009 學位論文 ; thesis 92 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 醫學工程研究所 === 97 === Hypertension, diabetes and stroke are the three major chronic diseases of the people in Taiwan. In the clinical applications, the benefit of invasive blood pressure measurement is that it can record the continuous pressure pulse accurately. However, it can’t be used in routine examination. Although the non-invasive blood pressure measurement can be used at home and in routine examination, it causes discomfort during measurement due to the high air pressure applied by the air pump. Besides, it can not be easily carried around because of its size. For these reasons, this study purposes to construct a novel blood pressure measurement device without the air cuff. The proposed device measures blood pressure through a mechanism that is made of silicon rubber. The system consists of a 8051F321 to control the measurement flow and perform necessary computation. Thus, the final result is a portable real-time non-invasive blood pressure measurement system. In this study, blood pressure readings were obtained using the new system and bedside monitor (Spacelabs Medical, model 90367) from ten young volunteers. The results of mean pressure, systolic pressure and diastolic pressure from the new system were all higher than those from bedside monitor. Including all measured blood pressure readings, the correlation coefficient between these two system for mean, systolic and diastolic pressures were 0.15, 0.18 and 0.29, respectively. Re-exam the collected data, we found that when the speed of pressure application is too fast or too slow or the obtained blood pressure waveform characteristic did not coincide with typical oscillometric measurement, large variations appear. However, after exclude the above mentioned measurements, there is no significant improvement, the correlation coefficients of mean, systolic and diastolic pressures were 0.16, 0.16 and 0.38, respectively. Further examination, we identified one more factor that can influence the measurement result that is, during the measurement, there must included more than eight blood pressure pulses that conformed with oscillometric blood pressure measurement characteristic. After eliminating these recorded, the correlation coefficient increased to 0.71, 0.60 and 0.41 for diastolic pressure, mean pressure and systolic pressure, respectively. We can conclude from these results that the accuracy can be improved effectively by defining the user regulation more precisely. The above mentioned interference factors can be identified and eliminated by the microprocessor to provide a reliable blood pressure measurement in practical applications. In this study, low accuracy is still troubling the current system. If the accuracy can be improved by incorporating the foregoing findings, this new system may replace the traditional devices in the future.
author2 Liang-Yu Shyu
author_facet Liang-Yu Shyu
Yao-Lin Kao
高耀臨
author Yao-Lin Kao
高耀臨
spellingShingle Yao-Lin Kao
高耀臨
Development of the novel cuff-less blood pressure measurement device
author_sort Yao-Lin Kao
title Development of the novel cuff-less blood pressure measurement device
title_short Development of the novel cuff-less blood pressure measurement device
title_full Development of the novel cuff-less blood pressure measurement device
title_fullStr Development of the novel cuff-less blood pressure measurement device
title_full_unstemmed Development of the novel cuff-less blood pressure measurement device
title_sort development of the novel cuff-less blood pressure measurement device
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/61779267871840670149
work_keys_str_mv AT yaolinkao developmentofthenovelcufflessbloodpressuremeasurementdevice
AT gāoyàolín developmentofthenovelcufflessbloodpressuremeasurementdevice
AT yaolinkao xīnxíngwúqìnángxuèyāliàngcèzhuāngzhìzhīkāifā
AT gāoyàolín xīnxíngwúqìnángxuèyāliàngcèzhuāngzhìzhīkāifā
_version_ 1717740776967897088