Study on the Electrochemical Machining mechanism for the fabrication of Micro Tungsten-rod
碩士 === 國立中山大學 === 機械與機電工程學系研究所 === 97 === In this study, an electrolytic micro-machining tester is employed to investigate the effects of supply voltage,electrode gap and initial machining position on the geometry of the tungsten needle. The tungsten needle to be electrolyzed is dipped in an aqueous...
Main Authors: | Cheng-da Huang, 黃成達 |
---|---|
Other Authors: | Yuang-Cherng Chiou |
Format: | Others |
Language: | zh-TW |
Published: |
2009
|
Online Access: | http://ndltd.ncl.edu.tw/handle/96542049917013446237 |
Similar Items
-
The Parametric Analysis in Fabrication of Tungsten Carbide Alloy Rod by Electrochemical Machining
by: Qing-huang Zhao, et al.
Published: (2015) -
A Hybrid Electrochemical Micro-Machining Method of Tungsten Microprobe
by: Yu-Cheng Lin, et al.
Published: (2012) -
Finishing process of a micro spherical tungsten electrode in electrochemical micro machining and its application
by: Hsiang-An Wang, et al.
Published: (2012) -
Effect of Tool Electrode Position on the shapes of Micro tungsten needle using electrochemical machining
by: Jing-mei Chou, et al.
Published: (2010) -
The Analysis on the Fabrication of Thread-like Micro-pins by Electrochemical Machining
by: Cheng-han Lee, et al.