A multi-function biomedical analog front end IC
碩士 === 國立臺灣大學 === 電機工程學研究所 === 97 === With the advancement and maturation of semiconductor technology, the digital and analog circuit has been integrated on the same chip. In recent years, because of the demand on biomedicine, CMOS bio-sensors have already realized successfully with CMOS technique,...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2009
|
Online Access: | http://ndltd.ncl.edu.tw/handle/93407066082979072037 |
id |
ndltd-TW-097NTU05442122 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-097NTU054421222016-05-02T04:11:10Z http://ndltd.ncl.edu.tw/handle/93407066082979072037 A multi-function biomedical analog front end IC 多功能之生醫類比前置電路 Yu-Ting Huang 黃瑜婷 碩士 國立臺灣大學 電機工程學研究所 97 With the advancement and maturation of semiconductor technology, the digital and analog circuit has been integrated on the same chip. In recent years, because of the demand on biomedicine, CMOS bio-sensors have already realized successfully with CMOS technique, achieving miniature, low noise, low power and low cost biomedical systems. In addition, analog front-end circuit with the function of signal arrangement is a critical component in the biomedical system. In this thesis, the main three pieces of circuit are instrumentation amplifier (IA), second-order LPF and a programmable gain amplifier (PGA). They are fabricated in TSMC 0.35μm CMOS 2P4M process. The first stage of the system is based on IA which had accomplished by our laboratory and through the digital control switch and feedback loop to carry out the circuit system with the function of adjusting different intensity signal. Then, using a two-order LPF ( Sallen-key circuit ) to suppress the spikes from the clock feedthrough and charge injection caused by nonideality of the chopper switches. Finally, the signal is further amplified by programmable gain amplifier in the last stage. In order to let the whole system to deal with a wide range of biomedical signals and attain appropriate adjustment according to different kind of small signal sources, the design relies on a switch on/off devise to achieve these multi-functions. The die area is 1.8mm x 1.35mm and the power consumption is 944.2uW from a 3V voltage supply. Shey-Shi Lu 呂學士 2009 學位論文 ; thesis 91 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣大學 === 電機工程學研究所 === 97 === With the advancement and maturation of semiconductor technology, the digital and analog circuit has been integrated on the same chip. In recent years, because of the demand on biomedicine, CMOS bio-sensors have already realized successfully with CMOS technique, achieving miniature, low noise, low power and low cost biomedical systems. In addition, analog front-end circuit with the function of signal arrangement is a critical component in the biomedical system. In this thesis, the main three pieces of circuit are instrumentation amplifier (IA), second-order LPF and a programmable gain amplifier (PGA). They are fabricated in TSMC 0.35μm CMOS 2P4M process.
The first stage of the system is based on IA which had accomplished by our laboratory and through the digital control switch and feedback loop to carry out the circuit system with the function of adjusting different intensity signal. Then, using a two-order LPF ( Sallen-key circuit ) to suppress the spikes from the clock feedthrough and charge injection caused by nonideality of the chopper switches. Finally, the signal is further amplified by programmable gain amplifier in the last stage. In order to let the whole system to deal with a wide range of biomedical signals and attain appropriate adjustment according to different kind of small signal sources, the design relies on a switch on/off devise to achieve these multi-functions. The die area is 1.8mm x 1.35mm and the power consumption is 944.2uW from a 3V voltage supply.
|
author2 |
Shey-Shi Lu |
author_facet |
Shey-Shi Lu Yu-Ting Huang 黃瑜婷 |
author |
Yu-Ting Huang 黃瑜婷 |
spellingShingle |
Yu-Ting Huang 黃瑜婷 A multi-function biomedical analog front end IC |
author_sort |
Yu-Ting Huang |
title |
A multi-function biomedical analog front end IC |
title_short |
A multi-function biomedical analog front end IC |
title_full |
A multi-function biomedical analog front end IC |
title_fullStr |
A multi-function biomedical analog front end IC |
title_full_unstemmed |
A multi-function biomedical analog front end IC |
title_sort |
multi-function biomedical analog front end ic |
publishDate |
2009 |
url |
http://ndltd.ncl.edu.tw/handle/93407066082979072037 |
work_keys_str_mv |
AT yutinghuang amultifunctionbiomedicalanalogfrontendic AT huángyútíng amultifunctionbiomedicalanalogfrontendic AT yutinghuang duōgōngnéngzhīshēngyīlèibǐqiánzhìdiànlù AT huángyútíng duōgōngnéngzhīshēngyīlèibǐqiánzhìdiànlù AT yutinghuang multifunctionbiomedicalanalogfrontendic AT huángyútíng multifunctionbiomedicalanalogfrontendic |
_version_ |
1718253253759598592 |