Flow and Contaminant Leakage ofExterior Suction Hoods

碩士 === 國立臺灣科技大學 === 機械工程系 === 97 === Experimental studies on the performance of the conventional exterior hood have been conducted. Flow patterns and contaminant leakage on hood was examined by laser light assisted smoked-flow visualization method. The local and global contaminant leakages were quan...

Full description

Bibliographic Details
Main Authors: Kuan-chung Tai, 戴冠中
Other Authors: Rong-fung Huang
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/33751283760273169051
id ndltd-TW-097NTUS5489039
record_format oai_dc
spelling ndltd-TW-097NTUS54890392016-05-02T04:11:34Z http://ndltd.ncl.edu.tw/handle/33751283760273169051 Flow and Contaminant Leakage ofExterior Suction Hoods 外裝型氣罩之流動型態與洩漏特性 Kuan-chung Tai 戴冠中 碩士 國立臺灣科技大學 機械工程系 97 Experimental studies on the performance of the conventional exterior hood have been conducted. Flow patterns and contaminant leakage on hood was examined by laser light assisted smoked-flow visualization method. The local and global contaminant leakages were quantified by measuring the concentration of SF6 tracer gas. It has been found that in the conventional exterior hood that the contaminant in front of the table was very vulnerable to external disturbances. From the gathered experimental results, the best operating condition was obtained and recommended for minimal contaminant leakage. It has been discovered that the conventional exterior hood can not isolate the contaminant because the suction flow rate is totally independent of the leakage. Rong-fung Huang 黃榮芳 2009 學位論文 ; thesis 219 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 機械工程系 === 97 === Experimental studies on the performance of the conventional exterior hood have been conducted. Flow patterns and contaminant leakage on hood was examined by laser light assisted smoked-flow visualization method. The local and global contaminant leakages were quantified by measuring the concentration of SF6 tracer gas. It has been found that in the conventional exterior hood that the contaminant in front of the table was very vulnerable to external disturbances. From the gathered experimental results, the best operating condition was obtained and recommended for minimal contaminant leakage. It has been discovered that the conventional exterior hood can not isolate the contaminant because the suction flow rate is totally independent of the leakage.
author2 Rong-fung Huang
author_facet Rong-fung Huang
Kuan-chung Tai
戴冠中
author Kuan-chung Tai
戴冠中
spellingShingle Kuan-chung Tai
戴冠中
Flow and Contaminant Leakage ofExterior Suction Hoods
author_sort Kuan-chung Tai
title Flow and Contaminant Leakage ofExterior Suction Hoods
title_short Flow and Contaminant Leakage ofExterior Suction Hoods
title_full Flow and Contaminant Leakage ofExterior Suction Hoods
title_fullStr Flow and Contaminant Leakage ofExterior Suction Hoods
title_full_unstemmed Flow and Contaminant Leakage ofExterior Suction Hoods
title_sort flow and contaminant leakage ofexterior suction hoods
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/33751283760273169051
work_keys_str_mv AT kuanchungtai flowandcontaminantleakageofexteriorsuctionhoods
AT dàiguānzhōng flowandcontaminantleakageofexteriorsuctionhoods
AT kuanchungtai wàizhuāngxíngqìzhàozhīliúdòngxíngtàiyǔxièlòutèxìng
AT dàiguānzhōng wàizhuāngxíngqìzhàozhīliúdòngxíngtàiyǔxièlòutèxìng
_version_ 1718254201503481856