Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 97 === The air conditioning systems of commercial buildings mostly employ the water-cooled, less with the air-cooled or evaporation-cooled systems. This study introduces the concept of SCOP (System coefficient of performance). The tools for the energy analysis a...

Full description

Bibliographic Details
Main Authors: Po-Chih Hsieh 謝博智, 謝博智
Other Authors: 蔡尤溪
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/e4uj6z
id ndltd-TW-097TIT05703001
record_format oai_dc
spelling ndltd-TW-097TIT057030012019-08-03T15:50:13Z http://ndltd.ncl.edu.tw/handle/e4uj6z Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings 冰水主機應用不同散熱方法之全年系統性能係數分析-以商業建築為例 Po-Chih Hsieh 謝博智 謝博智 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 97 The air conditioning systems of commercial buildings mostly employ the water-cooled, less with the air-cooled or evaporation-cooled systems. This study introduces the concept of SCOP (System coefficient of performance). The tools for the energy analysis are the DOE 2 eQUEST (Quick Energy Simulation Tool) program. Simulation of annual Coefficient of Performance for chillers using different heat rejections systems are applied to Commercial Buildings. It was found that the power consumption for chillers using different heat rejections are 808,928.6 kWh, 824,587.5 kWh, 750,396.0 kWh, respectively for water-cooled, air-cooled and evaporation-cooled. Then different energy-saving methods were simulated and analyzed. It was found that the VWV system can reduce 1.8~3% of annual energy use, and for VAV system 10~11%. If analyzed and compared for SCOP, the water-cooled is 2.97, the air-cooled is 2.74 and evaporation-cooled is 3.45. In the view of annual energy consumption, when without employing energy-saving measures for air conditioning system of commercial buildings, energy consumption is nearly the same for water-cooled or air cooling type. The study has found that the annual energy consumption and SCOP of evaporation-cooled is better than the other two heat rejection methods. 蔡尤溪 2009 學位論文 ; thesis 122 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 97 === The air conditioning systems of commercial buildings mostly employ the water-cooled, less with the air-cooled or evaporation-cooled systems. This study introduces the concept of SCOP (System coefficient of performance). The tools for the energy analysis are the DOE 2 eQUEST (Quick Energy Simulation Tool) program. Simulation of annual Coefficient of Performance for chillers using different heat rejections systems are applied to Commercial Buildings. It was found that the power consumption for chillers using different heat rejections are 808,928.6 kWh, 824,587.5 kWh, 750,396.0 kWh, respectively for water-cooled, air-cooled and evaporation-cooled. Then different energy-saving methods were simulated and analyzed. It was found that the VWV system can reduce 1.8~3% of annual energy use, and for VAV system 10~11%. If analyzed and compared for SCOP, the water-cooled is 2.97, the air-cooled is 2.74 and evaporation-cooled is 3.45. In the view of annual energy consumption, when without employing energy-saving measures for air conditioning system of commercial buildings, energy consumption is nearly the same for water-cooled or air cooling type. The study has found that the annual energy consumption and SCOP of evaporation-cooled is better than the other two heat rejection methods.
author2 蔡尤溪
author_facet 蔡尤溪
Po-Chih Hsieh 謝博智
謝博智
author Po-Chih Hsieh 謝博智
謝博智
spellingShingle Po-Chih Hsieh 謝博智
謝博智
Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings
author_sort Po-Chih Hsieh 謝博智
title Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings
title_short Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings
title_full Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings
title_fullStr Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings
title_full_unstemmed Annual Coefficient of Performance Analysis for Chillers Using Different Heat Rejections as Applied to Commercial Buildings
title_sort annual coefficient of performance analysis for chillers using different heat rejections as applied to commercial buildings
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/e4uj6z
work_keys_str_mv AT pochihhsiehxièbózhì annualcoefficientofperformanceanalysisforchillersusingdifferentheatrejectionsasappliedtocommercialbuildings
AT xièbózhì annualcoefficientofperformanceanalysisforchillersusingdifferentheatrejectionsasappliedtocommercialbuildings
AT pochihhsiehxièbózhì bīngshuǐzhǔjīyīngyòngbùtóngsànrèfāngfǎzhīquánniánxìtǒngxìngnéngxìshùfēnxīyǐshāngyèjiànzhúwèilì
AT xièbózhì bīngshuǐzhǔjīyīngyòngbùtóngsànrèfāngfǎzhīquánniánxìtǒngxìngnéngxìshùfēnxīyǐshāngyèjiànzhúwèilì
_version_ 1719231973078073344