Study of Three-Phase Input Single-Phase Output Uninterruptible Power System

碩士 === 國立高雄應用科技大學 === 電機工程系 === 98 === Three-phase four-wire distribution power systems have been widely applied in office buildings and manufacturing-office buildings to supply single-phase or three-phase loads. The uninterruptible power supply (UPS) is generally applied to supply the high quality...

Full description

Bibliographic Details
Main Authors: Kuo-Fung Huang, 黃國芳
Other Authors: Shih-Wei Kau
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/72813291767985353156
id ndltd-TW-098KUAS8442104
record_format oai_dc
spelling ndltd-TW-098KUAS84421042015-10-13T18:58:41Z http://ndltd.ncl.edu.tw/handle/72813291767985353156 Study of Three-Phase Input Single-Phase Output Uninterruptible Power System 三相輸入單相輸出不斷電電源系統之研究 Kuo-Fung Huang 黃國芳 碩士 國立高雄應用科技大學 電機工程系 98 Three-phase four-wire distribution power systems have been widely applied in office buildings and manufacturing-office buildings to supply single-phase or three-phase loads. The uninterruptible power supply (UPS) is generally applied to supply the high quality power to the computer and precise equipment. In this thesis, three-phase input single-phase output UPS, composed of three-phase AC-DC power converter, battery set and single-phase DC-AC inverter, is addressed. Several circuit topologies and control methods, applied for the power factor correction, are analyzed, and the advanced two switches based power factor correction circuit with a new power factor correction method is proposed and implemented in the three-phase AC-DC power converter. The three-phase input currents of proposed three-phase AC-DC power converter are balanced, sinusoidal and in phase with the three-phase utility voltages so as to perform the unity power factor. The single-phase DC-AC inverter is configured by a diode-clamped three-level inverter to generate a high quality voltage to the load regardless the utility is normal or not. Finally, the computer simulation is made to verify the performance of proposed UPS. The simulation results show the performance of proposed three-phase input single-phase output UPS is as expected. Shih-Wei Kau 葛世偉 2010 學位論文 ; thesis 106 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄應用科技大學 === 電機工程系 === 98 === Three-phase four-wire distribution power systems have been widely applied in office buildings and manufacturing-office buildings to supply single-phase or three-phase loads. The uninterruptible power supply (UPS) is generally applied to supply the high quality power to the computer and precise equipment. In this thesis, three-phase input single-phase output UPS, composed of three-phase AC-DC power converter, battery set and single-phase DC-AC inverter, is addressed. Several circuit topologies and control methods, applied for the power factor correction, are analyzed, and the advanced two switches based power factor correction circuit with a new power factor correction method is proposed and implemented in the three-phase AC-DC power converter. The three-phase input currents of proposed three-phase AC-DC power converter are balanced, sinusoidal and in phase with the three-phase utility voltages so as to perform the unity power factor. The single-phase DC-AC inverter is configured by a diode-clamped three-level inverter to generate a high quality voltage to the load regardless the utility is normal or not. Finally, the computer simulation is made to verify the performance of proposed UPS. The simulation results show the performance of proposed three-phase input single-phase output UPS is as expected.
author2 Shih-Wei Kau
author_facet Shih-Wei Kau
Kuo-Fung Huang
黃國芳
author Kuo-Fung Huang
黃國芳
spellingShingle Kuo-Fung Huang
黃國芳
Study of Three-Phase Input Single-Phase Output Uninterruptible Power System
author_sort Kuo-Fung Huang
title Study of Three-Phase Input Single-Phase Output Uninterruptible Power System
title_short Study of Three-Phase Input Single-Phase Output Uninterruptible Power System
title_full Study of Three-Phase Input Single-Phase Output Uninterruptible Power System
title_fullStr Study of Three-Phase Input Single-Phase Output Uninterruptible Power System
title_full_unstemmed Study of Three-Phase Input Single-Phase Output Uninterruptible Power System
title_sort study of three-phase input single-phase output uninterruptible power system
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/72813291767985353156
work_keys_str_mv AT kuofunghuang studyofthreephaseinputsinglephaseoutputuninterruptiblepowersystem
AT huángguófāng studyofthreephaseinputsinglephaseoutputuninterruptiblepowersystem
AT kuofunghuang sānxiāngshūrùdānxiāngshūchūbùduàndiàndiànyuánxìtǒngzhīyánjiū
AT huángguófāng sānxiāngshūrùdānxiāngshūchūbùduàndiàndiànyuánxìtǒngzhīyánjiū
_version_ 1718038789281021952