Modular Modern Microfluidic Chip System

碩士 === 國立屏東科技大學 === 車輛工程系所 === 98 ===   In this study, a so-called “Modern Microfluidic Chip System”(MMCS) which is under concept of micro total analysis system (μ-TAS) was designed. MMCS contains three subsystems: “pneumatic propel fluid system”, “chip platform” and “microfluidic detection chip”....

Full description

Bibliographic Details
Main Authors: Ming-Hsi Hsieh, 謝明熹
Other Authors: Chin-Lung Chang
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/60371086557822216981
id ndltd-TW-098NPUS5162027
record_format oai_dc
spelling ndltd-TW-098NPUS51620272016-12-22T04:18:19Z http://ndltd.ncl.edu.tw/handle/60371086557822216981 Modular Modern Microfluidic Chip System 模組化新型微流體晶片系統 Ming-Hsi Hsieh 謝明熹 碩士 國立屏東科技大學 車輛工程系所 98   In this study, a so-called “Modern Microfluidic Chip System”(MMCS) which is under concept of micro total analysis system (μ-TAS) was designed. MMCS contains three subsystems: “pneumatic propel fluid system”, “chip platform” and “microfluidic detection chip”. Traditional syringe pumps were replaced by the pneumatic propel fluid system propel fluid by compressed air. In order to improve the defects of the traditional syringe pumps, the solenoid valves and pressure regulating valves were used to control the opening-closing and the pressure. The basis of the chip platform is aluminum alloy, and the top of chip platform is PMMA. Chip platform could adjust the Nanoport shortcomings, which is without experimental preparation time and lower cost. The substrate of “microfluidic detection chip” is PMMA, micromachining the microchannel by CO2 laser, with the process faster, easier modification, and without using of photolithography process. The first generation of microfluidic glucose concentration detection chip used the “Double Parallel Connection Micromixer”(DPCM) and T-type fluid outlet micro-channel to mix the solution. The second generation of microfluidic glucose concentration detection chip with addition to the third mixing chamber and serpentine microchannel could increase mixing efficiency. In this study, glucose concentration was detected by DNS reagent method. The DNS reagent and the glucose solution inject into the detected chip and the volume ratio of 1:1, and then the chip was cooling to room temperature after heated, and placed into the spectrophotometer for detected absorbance at the wavelength of 540nm and drew the calibration curve and R2 value of the glucose solution. Hence, MMCS is convenient, simple, quick, no cross-contamination and can be disposable. Using modern microfluidic chip system for detection experiment of glucose concentration, R2 values can reach more than 0.995, the results showed that the “Modern Microfluidic Chip System” can be applied to the actual detection. Chin-Lung Chang Lung-Ming Fu 張金龍 傅龍明 2010 學位論文 ; thesis 78 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立屏東科技大學 === 車輛工程系所 === 98 ===   In this study, a so-called “Modern Microfluidic Chip System”(MMCS) which is under concept of micro total analysis system (μ-TAS) was designed. MMCS contains three subsystems: “pneumatic propel fluid system”, “chip platform” and “microfluidic detection chip”. Traditional syringe pumps were replaced by the pneumatic propel fluid system propel fluid by compressed air. In order to improve the defects of the traditional syringe pumps, the solenoid valves and pressure regulating valves were used to control the opening-closing and the pressure. The basis of the chip platform is aluminum alloy, and the top of chip platform is PMMA. Chip platform could adjust the Nanoport shortcomings, which is without experimental preparation time and lower cost. The substrate of “microfluidic detection chip” is PMMA, micromachining the microchannel by CO2 laser, with the process faster, easier modification, and without using of photolithography process. The first generation of microfluidic glucose concentration detection chip used the “Double Parallel Connection Micromixer”(DPCM) and T-type fluid outlet micro-channel to mix the solution. The second generation of microfluidic glucose concentration detection chip with addition to the third mixing chamber and serpentine microchannel could increase mixing efficiency. In this study, glucose concentration was detected by DNS reagent method. The DNS reagent and the glucose solution inject into the detected chip and the volume ratio of 1:1, and then the chip was cooling to room temperature after heated, and placed into the spectrophotometer for detected absorbance at the wavelength of 540nm and drew the calibration curve and R2 value of the glucose solution. Hence, MMCS is convenient, simple, quick, no cross-contamination and can be disposable. Using modern microfluidic chip system for detection experiment of glucose concentration, R2 values can reach more than 0.995, the results showed that the “Modern Microfluidic Chip System” can be applied to the actual detection.
author2 Chin-Lung Chang
author_facet Chin-Lung Chang
Ming-Hsi Hsieh
謝明熹
author Ming-Hsi Hsieh
謝明熹
spellingShingle Ming-Hsi Hsieh
謝明熹
Modular Modern Microfluidic Chip System
author_sort Ming-Hsi Hsieh
title Modular Modern Microfluidic Chip System
title_short Modular Modern Microfluidic Chip System
title_full Modular Modern Microfluidic Chip System
title_fullStr Modular Modern Microfluidic Chip System
title_full_unstemmed Modular Modern Microfluidic Chip System
title_sort modular modern microfluidic chip system
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/60371086557822216981
work_keys_str_mv AT minghsihsieh modularmodernmicrofluidicchipsystem
AT xièmíngxī modularmodernmicrofluidicchipsystem
AT minghsihsieh mózǔhuàxīnxíngwēiliútǐjīngpiànxìtǒng
AT xièmíngxī mózǔhuàxīnxíngwēiliútǐjīngpiànxìtǒng
_version_ 1718403916410912768