English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer

碩士 === 臺灣大學 === 化學研究所 === 98 === The counter-migration technique has been reported to couple low concentration charged cyclodextrin electrokinetic chromatography with electrospray ionization mass spectrometry detection without suffering ion suppression effect. However, if this approach is adoped to...

Full description

Bibliographic Details
Main Authors: Wen-Shuo Cheng, 鄭文碩
Other Authors: 何國榮
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/64362517781133483192
id ndltd-TW-098NTU05065084
record_format oai_dc
spelling ndltd-TW-098NTU050650842015-10-13T18:49:40Z http://ndltd.ncl.edu.tw/handle/64362517781133483192 English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer 對掌異構物於低濃度與高濃度非揮發性環糊精緩衝溶液之毛細管電泳質譜研究 Wen-Shuo Cheng 鄭文碩 碩士 臺灣大學 化學研究所 98 The counter-migration technique has been reported to couple low concentration charged cyclodextrin electrokinetic chromatography with electrospray ionization mass spectrometry detection without suffering ion suppression effect. However, if this approach is adoped to couple charged cyclodextrin electrokinetic chromatography with commercial CE-MS interface, the resolution could be decreased due to the depletion of charged cyclodextrin zone . With the use of a liquid-junction/low flow interface, the charged cyclodextrin migrated from the liquid junction reservoir to the separation column continuously to maintain the separation efficiency. However, certain enantioseparation operated under the condition that the higher concentration of cyclodextrin used to carry the analyte to achieve separation with negative polarity. A liquid-junction/low-flow interface was used to alleviate the ion separation by avoiding the entering of cyclodextrin into the ESI source. The charged cyclodextrin could be stayed in the liquid junction reservoir. Because of the higher interaction between the cyclodextrin and the analyte, the running buffer containing 20% methanol was added to the liquid junction reservoir to detach the cyclodextrin from the analyte. To avoid the entering of methanol into separation column during CD-EKC separation, a polyvinyl alcohol-coated column was used as the coating column. Both good chiral separation efficiency and low ion signal suppression could be achieved with this approach. 何國榮 2010 學位論文 ; thesis 75 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 臺灣大學 === 化學研究所 === 98 === The counter-migration technique has been reported to couple low concentration charged cyclodextrin electrokinetic chromatography with electrospray ionization mass spectrometry detection without suffering ion suppression effect. However, if this approach is adoped to couple charged cyclodextrin electrokinetic chromatography with commercial CE-MS interface, the resolution could be decreased due to the depletion of charged cyclodextrin zone . With the use of a liquid-junction/low flow interface, the charged cyclodextrin migrated from the liquid junction reservoir to the separation column continuously to maintain the separation efficiency. However, certain enantioseparation operated under the condition that the higher concentration of cyclodextrin used to carry the analyte to achieve separation with negative polarity. A liquid-junction/low-flow interface was used to alleviate the ion separation by avoiding the entering of cyclodextrin into the ESI source. The charged cyclodextrin could be stayed in the liquid junction reservoir. Because of the higher interaction between the cyclodextrin and the analyte, the running buffer containing 20% methanol was added to the liquid junction reservoir to detach the cyclodextrin from the analyte. To avoid the entering of methanol into separation column during CD-EKC separation, a polyvinyl alcohol-coated column was used as the coating column. Both good chiral separation efficiency and low ion signal suppression could be achieved with this approach.
author2 何國榮
author_facet 何國榮
Wen-Shuo Cheng
鄭文碩
author Wen-Shuo Cheng
鄭文碩
spellingShingle Wen-Shuo Cheng
鄭文碩
English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer
author_sort Wen-Shuo Cheng
title English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer
title_short English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer
title_full English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer
title_fullStr English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer
title_full_unstemmed English Thesis Title: Study of CE/MS in Chiral Separation Using Low Concentration and High Concentration Nonvolatile Cyclodextrin Buffer
title_sort english thesis title: study of ce/ms in chiral separation using low concentration and high concentration nonvolatile cyclodextrin buffer
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/64362517781133483192
work_keys_str_mv AT wenshuocheng englishthesistitlestudyofcemsinchiralseparationusinglowconcentrationandhighconcentrationnonvolatilecyclodextrinbuffer
AT zhèngwénshuò englishthesistitlestudyofcemsinchiralseparationusinglowconcentrationandhighconcentrationnonvolatilecyclodextrinbuffer
AT wenshuocheng duìzhǎngyìgòuwùyúdīnóngdùyǔgāonóngdùfēihuīfāxìnghuánhújīnghuǎnchōngróngyèzhīmáoxìguǎndiànyǒngzhìpǔyánjiū
AT zhèngwénshuò duìzhǎngyìgòuwùyúdīnóngdùyǔgāonóngdùfēihuīfāxìnghuánhújīnghuǎnchōngróngyèzhīmáoxìguǎndiànyǒngzhìpǔyánjiū
_version_ 1718038143084527616