Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System

博士 === 臺灣大學 === 機械工程學研究所 === 98 === This thesis numerically investigates the power consumption of the centralized air-conditioning system under several operation strategies and then concludes a method to implement in practice. First, this study compares the performances of four updating rules of the...

Full description

Bibliographic Details
Main Authors: Yu-Fu Kuo, 郭祐甫
Other Authors: 陳希立
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/75145977328509973046
id ndltd-TW-098NTU05489079
record_format oai_dc
spelling ndltd-TW-098NTU054890792015-10-13T18:49:39Z http://ndltd.ncl.edu.tw/handle/75145977328509973046 Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System 中央空調系統運轉耗能模擬與控制策略最佳化之研究 Yu-Fu Kuo 郭祐甫 博士 臺灣大學 機械工程學研究所 98 This thesis numerically investigates the power consumption of the centralized air-conditioning system under several operation strategies and then concludes a method to implement in practice. First, this study compares the performances of four updating rules of the particle swarm optimization through applying five mathematic problems. The linear-decayed inertia weight method is favorable for this study because of the stability of solutions searching. Then, four subjects, which are chiller-loading distribution, chillers and cooling towers cooperation, chilled-water and air-handler system cooperation and integrated centralized air-conditioning system operation, are specified to investigate the control strategies. The validations of the power consumption models of the air-conditioning components are accomplished. The simplified heat transfer models of cooling towers and wet finned-tube heat exchangers are also proposed and validated. The proposed simplified models can be implemented with a wide range and the predicting results are better than present models. The proposed operation strategy is optimal chilled-water supply temperature. In one sample case, the system operated under the proposed strategy can save the energy of 862.3 MW•hr and reduce the carbon-dioxide emission of 548.4 tons. The energy-saving rate can reach 14.85% compared with the energy consumption of the traditional operation strategy. The optimal chilled-water supply temperature can be correlated as a linear function of cooling load rate. Therefore, the chilled-water supply temperature can be adjusted easily and rapidly according to the system cooling load rate. 陳希立 2010 學位論文 ; thesis 163 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 博士 === 臺灣大學 === 機械工程學研究所 === 98 === This thesis numerically investigates the power consumption of the centralized air-conditioning system under several operation strategies and then concludes a method to implement in practice. First, this study compares the performances of four updating rules of the particle swarm optimization through applying five mathematic problems. The linear-decayed inertia weight method is favorable for this study because of the stability of solutions searching. Then, four subjects, which are chiller-loading distribution, chillers and cooling towers cooperation, chilled-water and air-handler system cooperation and integrated centralized air-conditioning system operation, are specified to investigate the control strategies. The validations of the power consumption models of the air-conditioning components are accomplished. The simplified heat transfer models of cooling towers and wet finned-tube heat exchangers are also proposed and validated. The proposed simplified models can be implemented with a wide range and the predicting results are better than present models. The proposed operation strategy is optimal chilled-water supply temperature. In one sample case, the system operated under the proposed strategy can save the energy of 862.3 MW•hr and reduce the carbon-dioxide emission of 548.4 tons. The energy-saving rate can reach 14.85% compared with the energy consumption of the traditional operation strategy. The optimal chilled-water supply temperature can be correlated as a linear function of cooling load rate. Therefore, the chilled-water supply temperature can be adjusted easily and rapidly according to the system cooling load rate.
author2 陳希立
author_facet 陳希立
Yu-Fu Kuo
郭祐甫
author Yu-Fu Kuo
郭祐甫
spellingShingle Yu-Fu Kuo
郭祐甫
Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System
author_sort Yu-Fu Kuo
title Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System
title_short Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System
title_full Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System
title_fullStr Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System
title_full_unstemmed Simulation of Energy Consumption and Optimization of Control Strategy of the Central Air-Conditioning System
title_sort simulation of energy consumption and optimization of control strategy of the central air-conditioning system
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/75145977328509973046
work_keys_str_mv AT yufukuo simulationofenergyconsumptionandoptimizationofcontrolstrategyofthecentralairconditioningsystem
AT guōyòufǔ simulationofenergyconsumptionandoptimizationofcontrolstrategyofthecentralairconditioningsystem
AT yufukuo zhōngyāngkōngdiàoxìtǒngyùnzhuǎnhàonéngmónǐyǔkòngzhìcèlüèzuìjiāhuàzhīyánjiū
AT guōyòufǔ zhōngyāngkōngdiàoxìtǒngyùnzhuǎnhàonéngmónǐyǔkòngzhìcèlüèzuìjiāhuàzhīyánjiū
_version_ 1718037697923121152