To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape

碩士 === 國立臺灣科技大學 === 資訊工程系 === 98 === The technology has become indispensable to modern science. Technology products are always full of around us. More and more products of technology have come out .Such as PDA, Smart phone, notebook also debit cards, electronic wallets and Internet banking... brings...

Full description

Bibliographic Details
Main Authors: Shih-wei Lai, 賴世偉
Other Authors: Shi-jinn Horng
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/06479236967192714205
id ndltd-TW-098NTUS5392069
record_format oai_dc
spelling ndltd-TW-098NTUS53920692016-04-22T04:23:47Z http://ndltd.ncl.edu.tw/handle/06479236967192714205 To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape 利用特徵點距離和靜脈形狀來設計一指靜脈辨識裝置 Shih-wei Lai 賴世偉 碩士 國立臺灣科技大學 資訊工程系 98 The technology has become indispensable to modern science. Technology products are always full of around us. More and more products of technology have come out .Such as PDA, Smart phone, notebook also debit cards, electronic wallets and Internet banking... brings convenient to our life . On the other hand it also brings security concerns. In order to solve these problems, the recognition methods related to biometric one after another. The vein recognition is the most popular in recent years. It uses the infrared LED irradiate fingers or palms to visualize the presentation of the vein biological characteristics .There are palm vein, finger vein, dorsal vein and wrist and some other. But in general, palm vein and the finger vein is the mainstream. This paper will use fewer the characteristics of fingers to do identify work. Firstly, we use Gaussian smoothing to do image enhancement. Secondly, we do the binaries according to the threshold value, then we thinning the image. In order to extract feature points (bifurcate points). Then calculate the distance between these feature points as a basis for matching. This method can resist a slight rotation and translation. Finally, we use the similarity of the vein shape to do the second matching. Make up the insufficiency that only uses the distance matching method. The experimental results confirm the method has the higher Identification rate, does not have the invasion and low cost than other papers. Shi-jinn Horng 洪西進 2010 學位論文 ; thesis 38 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 資訊工程系 === 98 === The technology has become indispensable to modern science. Technology products are always full of around us. More and more products of technology have come out .Such as PDA, Smart phone, notebook also debit cards, electronic wallets and Internet banking... brings convenient to our life . On the other hand it also brings security concerns. In order to solve these problems, the recognition methods related to biometric one after another. The vein recognition is the most popular in recent years. It uses the infrared LED irradiate fingers or palms to visualize the presentation of the vein biological characteristics .There are palm vein, finger vein, dorsal vein and wrist and some other. But in general, palm vein and the finger vein is the mainstream. This paper will use fewer the characteristics of fingers to do identify work. Firstly, we use Gaussian smoothing to do image enhancement. Secondly, we do the binaries according to the threshold value, then we thinning the image. In order to extract feature points (bifurcate points). Then calculate the distance between these feature points as a basis for matching. This method can resist a slight rotation and translation. Finally, we use the similarity of the vein shape to do the second matching. Make up the insufficiency that only uses the distance matching method. The experimental results confirm the method has the higher Identification rate, does not have the invasion and low cost than other papers.
author2 Shi-jinn Horng
author_facet Shi-jinn Horng
Shih-wei Lai
賴世偉
author Shih-wei Lai
賴世偉
spellingShingle Shih-wei Lai
賴世偉
To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape
author_sort Shih-wei Lai
title To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape
title_short To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape
title_full To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape
title_fullStr To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape
title_full_unstemmed To Design a Vein Recognition device Based on Distance of Feature Point and Vein Shape
title_sort to design a vein recognition device based on distance of feature point and vein shape
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/06479236967192714205
work_keys_str_mv AT shihweilai todesignaveinrecognitiondevicebasedondistanceoffeaturepointandveinshape
AT làishìwěi todesignaveinrecognitiondevicebasedondistanceoffeaturepointandveinshape
AT shihweilai lìyòngtèzhēngdiǎnjùlíhéjìngmàixíngzhuàngláishèjìyīzhǐjìngmàibiànshízhuāngzhì
AT làishìwěi lìyòngtèzhēngdiǎnjùlíhéjìngmàixíngzhuàngláishèjìyīzhǐjìngmàibiànshízhuāngzhì
_version_ 1718231241452421120