Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood

碩士 === 國立臺灣科技大學 === 機械工程系 === 98 === The air-curtain isolated chemical fume hood was successfully developed in previous research. By appropriately adjusting the physical parameters (e.g., suction velocity from the suction slot, blow-down velocity from the double-layered sash) and geometric designs,...

Full description

Bibliographic Details
Main Authors: Pei-yi Shin, 辛佩怡
Other Authors: Rong-fung Huang
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/33580493797965608565
id ndltd-TW-098NTUS5489036
record_format oai_dc
spelling ndltd-TW-098NTUS54890362016-04-22T04:23:32Z http://ndltd.ncl.edu.tw/handle/33580493797965608565 Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood 高溫作業對氣簾式氣櫃流場之影響與洩漏特性 Pei-yi Shin 辛佩怡 碩士 國立臺灣科技大學 機械工程系 98 The air-curtain isolated chemical fume hood was successfully developed in previous research. By appropriately adjusting the physical parameters (e.g., suction velocity from the suction slot, blow-down velocity from the double-layered sash) and geometric designs, the air-curtain fume hood has been approved as an “almost zero-leakage” apparatus. However, previous research did not show the performance and optimized operation parameters as a high-temperature pollutant source was generated in the hood. No answers to the leakages from the hood top and the sash opening were obtained. The aim of the present work is focused on studying the effects of the high temperature plume on the flow field and the leakage of tracer gas from the sash opening under the high temperature operation situation. Flow visualization and velocimeter measurement were firstly performed to obtain the flow characteristics. By using the observed flow characteristics, the optimized operation parameters and strategy for high-temperature operation were suggested. The tracer-gas concentration tests partially simulating EN 14175-3:2003 protocal for the walk-by motions were subsequently conducted to obtain the quantitative leakage data and also to validate the optimized operation parameters and strategy. The results show that the air-curtain hood presents excellent performance even under high-temperature operation at 300 oC if operation parameters are properly adjusted. Rong-fung Huang 黃榮芳 2010 學位論文 ; thesis 174 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 機械工程系 === 98 === The air-curtain isolated chemical fume hood was successfully developed in previous research. By appropriately adjusting the physical parameters (e.g., suction velocity from the suction slot, blow-down velocity from the double-layered sash) and geometric designs, the air-curtain fume hood has been approved as an “almost zero-leakage” apparatus. However, previous research did not show the performance and optimized operation parameters as a high-temperature pollutant source was generated in the hood. No answers to the leakages from the hood top and the sash opening were obtained. The aim of the present work is focused on studying the effects of the high temperature plume on the flow field and the leakage of tracer gas from the sash opening under the high temperature operation situation. Flow visualization and velocimeter measurement were firstly performed to obtain the flow characteristics. By using the observed flow characteristics, the optimized operation parameters and strategy for high-temperature operation were suggested. The tracer-gas concentration tests partially simulating EN 14175-3:2003 protocal for the walk-by motions were subsequently conducted to obtain the quantitative leakage data and also to validate the optimized operation parameters and strategy. The results show that the air-curtain hood presents excellent performance even under high-temperature operation at 300 oC if operation parameters are properly adjusted.
author2 Rong-fung Huang
author_facet Rong-fung Huang
Pei-yi Shin
辛佩怡
author Pei-yi Shin
辛佩怡
spellingShingle Pei-yi Shin
辛佩怡
Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood
author_sort Pei-yi Shin
title Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood
title_short Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood
title_full Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood
title_fullStr Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood
title_full_unstemmed Influences of High-temperature Operation on Flow and Containment Characteristics of Air-curtain Fume Hood
title_sort influences of high-temperature operation on flow and containment characteristics of air-curtain fume hood
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/33580493797965608565
work_keys_str_mv AT peiyishin influencesofhightemperatureoperationonflowandcontainmentcharacteristicsofaircurtainfumehood
AT xīnpèiyí influencesofhightemperatureoperationonflowandcontainmentcharacteristicsofaircurtainfumehood
AT peiyishin gāowēnzuòyèduìqìliánshìqìguìliúchǎngzhīyǐngxiǎngyǔxièlòutèxìng
AT xīnpèiyí gāowēnzuòyèduìqìliánshìqìguìliúchǎngzhīyǐngxiǎngyǔxièlòutèxìng
_version_ 1718231415470948352