Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District

碩士 === 中華科技大學 === 土木防災工程研究所 === 99 === Xizhi has always been known as a place of flood. Situated within the path where typhoons often occur, the impression that flooding never ceases in Taiwan stays with the public. Confronted by global changes in the environment, the frequency of typhoon with its p...

Full description

Bibliographic Details
Main Authors: Chen chin.han, 陳錦翰
Other Authors: Horng-yu Yang
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/56886004687387269106
id ndltd-TW-099CHIT0653005
record_format oai_dc
spelling ndltd-TW-099CHIT06530052015-10-28T04:06:49Z http://ndltd.ncl.edu.tw/handle/56886004687387269106 Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District 雨水下水道配合防洪抽水站操作風險評估之研究-以新北市汐止區為例 Chen chin.han 陳錦翰 碩士 中華科技大學 土木防災工程研究所 99 Xizhi has always been known as a place of flood. Situated within the path where typhoons often occur, the impression that flooding never ceases in Taiwan stays with the public. Confronted by global changes in the environment, the frequency of typhoon with its precipitation has brought several major disasters. For reducing the occurrence of flooding, dikes shall be heightened and pump stations shall be increased. In addition, the underground sewer system should also be utilized in conjunction with pump stations as ways to discharge waters out of dikes. Other than natural factors such as precipitation level, human factors are more severe to the cause of flooding disasters. Flooding disaster events from 1987 to 2011 were analyzed by the study, it was found that the majority of disasters 75% are due to malfunctions of facilities such as pump stations and underground sewers. Using the most disastrous case of Typhoon Nari and the flooding case near Keelung as examples, the study analyzes the risk control strategy and response when underground sewer systems are used in conjunction with pump stations. From risk assessment, the result showed that human cause to the malfunction of pump stations is the primary reason 60% of flooding disaster. Human cause to the ineffectiveness of drainage ranks second, at 25%. The study quantifies the risk factor in the two flooding cases of Typhoon Nari and Keelung downpour. The cases were graded as H16 which means unacceptable and requires immediate improvement. Through the analysis of risk reducing strategy, it was found that flooding disaster could be reduced by more than 50% if risk factors of pump station malfunction and faulty human operation are reduced, which means M8 grading for impending review and L3 grading for acceptable. For comprehensive consideration, operation procedure and specialized management can be review further in the study. The findings may be provided to government agencies for references to the management of underground sewers and pump stations so that the threat of human lives and properties is reduced in the event of typhoons and downpours, thereby benefiting the public. Keywords: Rain Water Sewer, Flood Pumping Station, Risk Management, Risk Quantification Model Horng-yu Yang 楊宏宇 2011 學位論文 ; thesis 78 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中華科技大學 === 土木防災工程研究所 === 99 === Xizhi has always been known as a place of flood. Situated within the path where typhoons often occur, the impression that flooding never ceases in Taiwan stays with the public. Confronted by global changes in the environment, the frequency of typhoon with its precipitation has brought several major disasters. For reducing the occurrence of flooding, dikes shall be heightened and pump stations shall be increased. In addition, the underground sewer system should also be utilized in conjunction with pump stations as ways to discharge waters out of dikes. Other than natural factors such as precipitation level, human factors are more severe to the cause of flooding disasters. Flooding disaster events from 1987 to 2011 were analyzed by the study, it was found that the majority of disasters 75% are due to malfunctions of facilities such as pump stations and underground sewers. Using the most disastrous case of Typhoon Nari and the flooding case near Keelung as examples, the study analyzes the risk control strategy and response when underground sewer systems are used in conjunction with pump stations. From risk assessment, the result showed that human cause to the malfunction of pump stations is the primary reason 60% of flooding disaster. Human cause to the ineffectiveness of drainage ranks second, at 25%. The study quantifies the risk factor in the two flooding cases of Typhoon Nari and Keelung downpour. The cases were graded as H16 which means unacceptable and requires immediate improvement. Through the analysis of risk reducing strategy, it was found that flooding disaster could be reduced by more than 50% if risk factors of pump station malfunction and faulty human operation are reduced, which means M8 grading for impending review and L3 grading for acceptable. For comprehensive consideration, operation procedure and specialized management can be review further in the study. The findings may be provided to government agencies for references to the management of underground sewers and pump stations so that the threat of human lives and properties is reduced in the event of typhoons and downpours, thereby benefiting the public. Keywords: Rain Water Sewer, Flood Pumping Station, Risk Management, Risk Quantification Model
author2 Horng-yu Yang
author_facet Horng-yu Yang
Chen chin.han
陳錦翰
author Chen chin.han
陳錦翰
spellingShingle Chen chin.han
陳錦翰
Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District
author_sort Chen chin.han
title Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District
title_short Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District
title_full Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District
title_fullStr Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District
title_full_unstemmed Operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – A case tudy of the New Taipei City Xizhi District
title_sort operational risk assessment of flood pumping station in conjunction with underground rainwater sewer – a case tudy of the new taipei city xizhi district
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/56886004687387269106
work_keys_str_mv AT chenchinhan operationalriskassessmentoffloodpumpingstationinconjunctionwithundergroundrainwaterseweracasetudyofthenewtaipeicityxizhidistrict
AT chénjǐnhàn operationalriskassessmentoffloodpumpingstationinconjunctionwithundergroundrainwaterseweracasetudyofthenewtaipeicityxizhidistrict
AT chenchinhan yǔshuǐxiàshuǐdàopèihéfánghóngchōushuǐzhàncāozuòfēngxiǎnpínggūzhīyánjiūyǐxīnběishìxīzhǐqūwèilì
AT chénjǐnhàn yǔshuǐxiàshuǐdàopèihéfánghóngchōushuǐzhàncāozuòfēngxiǎnpínggūzhīyánjiūyǐxīnběishìxīzhǐqūwèilì
_version_ 1718112678788988928